Beckhoff C9900-E768 CP6xxx and CP7xxx Control Panel Push-Button Extension

Beckhoff C9900-E768 CP6xxx and CP7xxx Control Panel Push-Button Extension

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: C9900-E768

  • Negara asal:Jerman

  • Jenis Produk: Push-Button Extensions

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed to expand physical operator interfaces on machine-level HMI installations, the BECKHOFF C9900-E768 provides external tactile controls mounted directly on the right side of compatible industrial displays. Built specifically for 15-inch CP6x22-00xx and CP7x22-00xx Control Panels and Panel PCs operating without integrated keyboards, this auxiliary module adds heavy-duty physical control keys while maintaining structural integration. It is an optimal hardware solution for applications transitioning through the manufacturer's active service phase, ensuring legacy systems maintain tactile controls. The integration of Siemens Signum square hardware and dual-path connection mechanisms delivers rugged and reliable performance in demanding industrial environments.

Features

  • Right-Side Interface Extension: Seamlessly mounts onto the right frame of 15-inch Beckhoff display units.
  • Industrial Key Array: Features 14 Siemens Signum square (30 x 30 mm) push-buttons equipped with integrated signal lamps.
  • Dedicated Emergency Stop: Includes 1 high-visibility Siemens Signum emergency stop button designed for direct hardware safety circuit routing.
  • Dual Contact Functionality: Supports a primary normally-open (NO) contact routed over CP-Link or USB, alongside a secondary hardwired NO contact accessible via a terminal row.
  • Customizable Marking: Clear, insertable label caps allow rapid on-site labeling of individual button functions.

Applications

  • Automotive Assembly Lines: Integrated right-side controls for manual machine overrides and system restarts.
  • Process Plant Visualization: Hardwired E-stop and control interface expansion directly adjacent to the main screen.
  • Legacy Panel Maintenance: Direct drop-in component replacement for CP6x22 and CP7x22 installations requiring ongoing service lifecycle support.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation GmbH & Co. KG
Article Number / SKU C9900-E768
Compatible Displays 15-inch CP6xxx and CP7xxx without built-in keyboard (specifically CP6x22-00xx and CP7x22-00xx)
Mounting Position Right-hand side of panel
Push-Button Type 14 x Siemens Signum square, 30 x 30 mm
Emergency Stop Type 1 x Siemens Signum, direct hardwire configuration
Key Signal Transmission USB or CP-Link (Contact 1) / Direct terminal strip (Contact 2)
Lamp Signal Transmission Exclusively via CP-Link or USB interface
Lifecycle Phase Service Phase (Legacy Support)
Shipping Weight 5.0 kg (11.0 lbs)

Connections and Interfaces

Interface Path Function and Wiring Assignment
CP-Link / USB Bus Connection Transmits digital key state of Contact 1 for all 14 push-buttons; drives power to all integrated signal lamps.
Rear Terminal Strip Provides independent, hardwired access to the isolated Contact 2 (Normally Open) of each of the 14 push-buttons.
Emergency Stop Terminals Dedicated, fully-isolated terminal block for direct wiring of the E-stop switch into the plant's physical safety relay circuit.

Empirical Engineering Insights

Alternative Models & Compatibility

This expansion panel is designed specifically for Beckhoff 15-inch displays. Attempting to fit this mechanical layout onto 12-inch or 19-inch variants will lead to misalignment of the chassis mating holes and failure of physical integration. For servicing older CP6x22 and CP7x22 variants, ensure the firmware revision of the host controller supports the dual-contact configuration over CP-Link if you intend to run control loops without auxiliary terminal-row wiring.

Application Pitfalls & Engineering Notes

A common design pitfall is attempting to hardwire the 14 integrated signal lamps. These lamps receive power and commands strictly through the USB/CP-Link bus connection. If the digital communication link is disrupted, the signal lamps will not function, even if the secondary NO contacts of the push-buttons remain functional via the hardwired terminal strip.

Commissioning & Wiring Tips

Always separate the hardwired digital input cabling connected to the secondary terminal row from high-voltage AC cables in the wire duct to prevent noise coupling on long runs. For high-vibration applications, verify that cable strain reliefs are anchored within the panel enclosure to prevent tension on the interface connector.

Installation Guidelines

CRITICAL WARNING: SAFETY COMPLIANCE REQUIRED

Isolate and lock out all electrical power supplying the Control Panel/Panel PC and all auxiliary terminal strip voltages before initiating the mechanical connection of the C9900-E768. The emergency stop circuit must undergo a full functional validation test before returning the machine to production.

1

Align the push-button extension housing with the pre-machined mounting points on the right-hand side of the 15-inch Control Panel.

2

Secure the mechanical assembly using the specified OEM fasteners, ensuring the integrated perimeter gasket forms a tight seal against dust and liquid ingress.

3

Connect the internal USB or CP-Link wiring harness to interface the button outputs and primary lamp controls with the panel's main logic board.

4

Wire the physical E-stop switch directly to your safety relay, and optionally terminate the redundant secondary NO contacts to your PLC's input modules via the integrated terminal strip.

Loading product navigation…

Can the signal lamps on the C9900-E768 be hardwired directly to an external output block?

No. The 14 internal signal lamps are driven exclusively via the bus interface (CP-Link or USB). Direct physical terminal wiring is not available for these lamps.

How are the dual-contact push-buttons configured for control redundancy?

Each of the 14 push-buttons is equipped with two normally-open (NO) contacts. Contact 1 is transmitted electronically via USB/CP-Link, while Contact 2 is directly wireable to an physical I/O card using the built-in terminal strip.

Is the integrated emergency stop button active over the USB or CP-Link interface?

No. The Siemens Signum emergency stop button is completely isolated from the digital bus connection and must be hardwired directly to a safety controller or safety relay.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...