1 dari 1

Beckhoff C9900-E771 Control Panel Accessory Push-button Extension

Beckhoff C9900-E771 Control Panel Accessory Push-button Extension

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: C9900-E771

  • Negara asal:Jerman

  • Jenis Produk: HMI and Control Panel Accessories

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Optimized for right-hand integration on 15-inch display layouts, the Beckhoff C9900-E771 provides robust tactile operator input for legacy CP6x32-00xx and CP7x32-00xx control platforms. Designed for demanding HMI environments, this industrial push-button extension complements host panels without integrated keyboards by adding physical buttons, safety-critical emergency stops, and visual feedback lamps. The unit supports dual-channel signal architecture, combining digital bus transmission (via CP-Link or USB) with direct-wire terminal connections to guarantee system interoperability and fail-safe hardware control.

Features

  • Right-Side Mounting: Engineered specifically to match the physical chassis alignment of 15-inch host panel housings.
  • 18 Illuminated Push-buttons: Equipped with industrial-grade Siemens Signum square keys (30 x 30 mm) featuring built-in signal lamps.
  • Integrated Emergency Stop: Features one heavy-duty Siemens Signum emergency stop button designed for direct hardware wiring.
  • Customizable Labeling: Clear push-button caps permit the insertion of individual custom text or symbol labels for site-specific functions.
  • Dual-Signal Pathways: Every push-button is configured with one normally-open (NO) contact mapped to USB/CP-Link and a second independent NO contact wired directly to a terminal block.
  • Bus-Driven Feedback: Status and signal lamps are mapped and controlled solely through the host CP-Link or USB interface.

Applications

  • Legacy Machinery Retrofits: Direct physical integration with active CP6x32 and CP7x32 operator panels.
  • Process Safety Interfaces: Deployments requiring physical, hardwired emergency-stop circuits adjacent to the software display.
  • Automotive and Assembly Lines: Environments where gloved operators require high-tactility feedback over standard touchscreens.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model Reference C9900-E771
Device Type Push-button extension
Host Panel Compatibility CP6x32-00xx, CP7x32-00xx (15-inch displays without keyboard)
Mounting Location Right side of host chassis
Push-Button Element 18 x Siemens Signum square, 30 x 30 mm
Emergency Stop Element 1 x Siemens Signum, direct-wire design
Contact Configuration Normally-Open (NO) x 2 per button (1 x bus, 1 x physical terminal)
Transmission Standard CP-Link or USB (for push-button digital signals and lamp drivers)
Lifecycle Phase Service Phase (Legacy support and spare part availability)
Country of Origin Germany
Shipping Weight 5.00 kg (Estimated)

Connections and Interfaces

Connection Node / Port Functional Assignment
CP-Link / USB Bus Connection Transmits Contact 1 state of all 18 buttons and powers internal status lamps.
Internal Terminal Strip Exposes Contact 2 (Normally Open) for direct electrical wiring to PLC input cards.
Emergency Stop Terminals Dedicated hardwire connection block directly feeding the active-safe E-Stop contacts.

Alternative Models & Compatibility

The C9900-E771 is specifically tailored to complement the dimensional aspect ratio and screw alignments of 15-inch host housings (CP6x32 and CP7x32). While electrically compatible with USB and CP-Link variants across other chassis lines, it cannot be physically mounted to 12-inch or 19-inch panels due to frame height variances. Ensure your physical configuration aligns with the correct target display sizes prior to procurement.

Application Pitfalls & Engineering Notes

Note that status lamps are powered and mapped solely through the CP-Link or USB communication line. In the event of a bus loss, lamp states will fail to update. For safety-critical status loops, the second NO hardware contact on the terminal block should be used to run a physical loopback to an isolated PLC input card, ensuring logic verification independent of the display link.

Commissioning & Wiring Tips

When wiring the direct-access terminal row, use a shielded control cable if routing paths are adjacent to variable frequency drives (VFDs) or three-phase power lines. Connect the cable shield to the cabinet grounding bar. This suppresses transient noise that can trigger false contact state transitions on standard 24V PLC input lines.

Installation Guidelines

CRITICAL WARNING

De-energize the host control panel and any associated 24V DC terminal power lines before physically coupling this expansion unit. Failure to fully discharge system voltage prior to interface connection risks damaging USB controller logic boards and causing terminal short-circuits.

1

Align the expansion bracket of the C9900-E771 with the right-hand mounting track of the host 15-inch control panel.

2

Secure the unit physically using the supplied mounting bolts, ensuring correct torque limits to preserve IP rating integrity.

3

Wire the emergency stop contact block directly into your hardwired safety-monitoring loop (e.g., safety relay or safety PLC).

4

Connect the internal terminal block wiring to the PLC's local digital inputs, if using secondary contact loopbacks.

5

Attach the internal USB or CP-Link connector cable to the designated port on the host computer board, then restore power to test lamp cycles.

Loading product navigation…

Can I mount the C9900-E771 on the left side of my control panel?

No. The mechanical mounting brackets, frame offset, and wiring path design of the C9900-E771 are configured strictly for right-side installation on compatible 15-inch Beckhoff panels.

How are the status lamps on the extension controlled?

The integrated status lamps are driven digitally via the host's USB or CP-Link interface. They cannot be directly illuminated using the secondary physical terminal strip.

Is the emergency stop button safety-bus compatible?

Yes, but it must be wired directly. The emergency stop is designed for hardwired integration into your physical safety loop or local safety-monitoring relay (such as TwinSAFE), ensuring it operates independently of standard HMI runtime software.

What is the function of the dual normally-open (NO) contacts?

The dual-contact layout allows for redundancy or split tasks. The first contact state is transmitted digitally via CP-Link/USB to your control application, while the second contact is accessible via the hardware terminal block for legacy direct wiring to traditional PLC input cards.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...