1 dari 1

BECKHOFF ERI4374-0002 IO-Link Box

BECKHOFF ERI4374-0002 IO-Link Box

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: ERI4374-0002

  • Negara asal:Jerman

  • Jenis Produk: IO-Link Modules

  • Pembayaran: T/T, Western Union

  • Berat: 265g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Providing robust decentralized analog processing, the BECKHOFF ERI4374-0002 IO-Link box integrates versatile analog input and output capabilities directly into the field level. Designed to eliminate the need for protective control cabinets, this rugged combi module features two analog inputs and two analog outputs that can be parameterized independently for voltage (-10/0...+10 V) or current (0/4...20 mA) signals.

Operating via high-speed IO-Link communication under specification V1.1 (Class B) at data transfer rates up to 230.4 kbaud (COM3), this fieldbus module delivers precise 16-bit signal conversion. The heavy-duty zinc die-cast encapsulation ensures high resistance to mechanical stress, vibration, and environmental ingress, making it an ideal choice for challenging modern manufacturing environments.

Features

  • Dual-Function Configuration: Combines 2 analog inputs and 2 analog outputs in a single IP67-rated housing.
  • Flexible Signal Selection: Each channel can be individually configured for -10/0...+10 V or 0/4...20 mA signals.
  • High-Performance Conversion: Rapid input conversion times of approximately 100 microseconds and output response times of roughly 40 microseconds.
  • High-Resolution Signal Processing: 16-bit resolution (including sign) with an accuracy limit of less than 0.1% relative to the full scale value.
  • Ruggedized Design: Die-cast zinc housing with IP65, IP66, and IP67 protection ratings, enabling direct on-machine mounting.
  • Optimized Communication: Features an A-coded M12 connector supporting IO-Link V1.1 Class B communication at COM3 speeds.

Applications

  • Decentralized process data acquisition in automotive and machine building plants.
  • Direct control of proportional valves and hydraulic positioning systems.
  • Distributed analog sensor integration in hazardous or high-moisture production zones.
  • Testing rigs and assembly lines requiring compact, cabinet-free I/O layouts.

Technical Specifications

Manufacturer BECKHOFF
Part Number ERI4374-0002
Module Type IO-Link Box (Analog Input/Output Combi Module)
Communication Interface IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM3)
Connection Interface 1 x M12 plug, A-coded
Number of Channels 2 analog inputs + 2 analog outputs
Signal Configuration -10/0...+10 V | 0/4...20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Conversion Time Input: ~100 microseconds | Output: ~40 microseconds
Input Filter Limit Frequency 5 kHz
Measurement Error < 0.1% (relative to full scale value)
Input Resistance Voltage: > 200 kOhm | Current: typ. 85 Ohm + diode voltage
Output Load Resistance Voltage: > 5 kOhm | Current: < 500 Ohm
Common-Mode Voltage (UCM) max. 35 V
Electrical Isolation Yes (L+/P24)
Current Consumption typ. 100 mA from L+
Housing Material Zinc die-cast
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Weight approx. 265 g

Connections and Interfaces

Connection Type Interface Style Function
IO-Link Port M12, A-coded plug Master connection, power supply, and data transmission
Analog Inputs/Outputs M12, screw type Sensor and actuator physical connections

Installation Guidelines

  • Mounting Location: The module can be installed in any physical orientation directly onto machine frames or structural profiles. Use the integrated mounting holes to secure the unit.
  • Grounding and Shielding: Ensure the zinc die-cast housing has low-resistance contact to a grounded machine frame to maximize EMC protection. Use shielded cabling for all analog signals.
  • Environmental Sealing: To achieve IP65/66/67 ingress protection, ensure all unused M12 connectors are sealed with appropriate protective caps, and all connected cables are tightened to the specified torque.
  • Power Integrity: Verify that the IO-Link Class B port is connected to an approved master providing the correct auxiliary power (P24) and logic power (L+) levels.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

Can the analog channels on the ERI4374-0002 be configured individually?

Yes, each of the two analog inputs and two analog outputs can be independently parameterized for either voltage (-10/0...+10 V) or current (0/4...20 mA) signals.

Does this IO-Link box require an external protective enclosure?

No. The Beckhoff ERI4374-0002 features a robust, encapsulated zinc die-cast housing rated at IP65, IP66, and IP67, making it suitable for direct machine mounting without a control cabinet.

What is the resolution and measurement accuracy of this module?

The module processes signals at a high 16-bit resolution (including sign) with an overall measurement uncertainty/error of less than 0.1% relative to the full scale value.

What IO-Link standard does the ERI4374-0002 utilize?

The module conforms to the IO-Link V1.1 Class B specification and operates at the high-speed COM3 transmission rate of 230.4 kbaud.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...