1 dari 1

Beckhoff IP2042-B318 Fieldbus Box 8-Channel Digital Output Module

Beckhoff IP2042-B318 Fieldbus Box 8-Channel Digital Output Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IP2042-B318

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 30 mm x 210 mm x 26.5 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed to drive high-current actuators directly in decentralized industrial architectures, the Beckhoff IP2042-B318 establishes a rugged, high-density digital control interface over PROFIBUS DP networks. This IP67-rated module facilitates direct on-machine installation without a protective control cabinet, consolidating 8 channels of digital outputs operating at 24 V DC. With a heavy-duty capacity of 2 A per channel (up to an aggregate limit of 12 A), the unit is engineered to power demanding field loads such as solenoid valves, contactors, and indicators in challenging industrial environments.

Features

  • 8 Digital Outputs: Delivers 24 V DC switching with individual short-circuit protection per channel.
  • High Current Capacity: Supports up to 2 A per output channel, with an overall module sum limit of 12 A.
  • Integrated PROFIBUS Interface: Features an integrated T-connector layout (1 x M12 socket and 1 x M12 plug, B-coded) to streamline daisy-chain network topology.
  • Automatic Baud Rate Detection: Automatically syncs with bus speeds ranging up to 12 Mbaud.
  • Rugged Field Housing: IP65/66/67-rated polyamide encapsulation ensures complete dust-tight performance and water resistance.
  • Flexible Diagnostics: Configurable via the KS2000 commissioning software interface or directly via the main controller platform using DP-V1 extensions.

Applications

  • Decentralized, cabinet-free machine control architectures.
  • Heavy material handling, packaging lines, and conveyor networks.
  • Direct control of high-current pneumatic and hydraulic valve blocks.
  • Automotive assembly plants and robotic cell integration.

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number IP2042-B318
Protocol / Interface PROFIBUS DP
Number of Outputs 8 digital outputs
Output Type Ohmic, inductive, and lamp loads
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 2 A per channel (short-circuit proof)
Total Aggregate Current Max. 12 A total (Grouped limits: Channels 0-3 sum 4 A; 4-5 sum 4 A; 6-7 sum 4 A)
Data Transfer Rates Automatic detection up to 12 Mbaud
Power Supply Connection Feed: 2 x M8 male socket, 4-pin (no downstream pass-through)
Box Supply Current 85 mA + sensor consumption (Max. 0.5 A)
Housing Material Polyamide (PA6)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm (XXL Housing)
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Interface Type Connector Details Functional Assignment
PROFIBUS Input 1 x M12 plug, 5-pin, B-coded Incoming fieldbus communication line
PROFIBUS Output 1 x M12 socket, 5-pin, B-coded Downstream line extension (Integrated T-connector)
Digital Outputs (0 to 7) M12, screw type sockets 24 V DC actuators / load connections
Power Supply 2 x M8 male socket, 4-pin Control voltage (Us) and Load voltage (Up) feed lines

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2042-B318 is built specifically for PROFIBUS DP architectures. When transitioning from classic cabinet modules to machine-mount field modules, verify that your PLC's hardware configuration utilizes the correct GSD database file for the IPxxxx-B31x series. Ensure that the bus master supports DP-V1 extensions if remote diagnostics or software-based configuration via KS2000 is required.

Application Pitfalls & Engineering Notes

While individual outputs are rated for up to 2 A, the module's total aggregate output is constrained by internal grouping limits to prevent localized overheating. Ensure your design maps high-draw actuators across separate logical groups (Channel 0 to 3, Channel 4 to 5, and Channel 6 to 7) to avoid tripping the individual 4 A group thermal protection limits even if the total load stays below the overall 12 A maximum limit.

Commissioning & Wiring Tips

To guarantee network stability, use high-quality, double-shielded copper PROFIBUS cables (2 x 0.25 mm²). Ensure the B-coded M12 connections are fully torqued to maintain the IP67 ingress protection rating. Unused M12 and M8 ports must be sealed with protective screw caps to prevent moisture ingress, which can disrupt internal diagnostic systems or lead to ground faults.

Installation Guidelines

CRITICAL WARNING: Ensure all power supplies (both control voltage Us and load voltage Up) are physically disconnected and locked out prior to commencing physical installation, wiring, or bus configuration. Failure to do so can result in equipment damage or unexpected actuator activation.
1

Mount the module housing directly to the machine frame using the two 3.5 mm diameter mounting holes. Use standard M3 fasteners to secure the unit.

2

Connect the incoming PROFIBUS line to the B-coded M12 plug interface, and route downstream segments from the integrated M12 socket if utilizing a daisy-chain setup.

3

Wire the actuators to the respective M12 output screw-type sockets. Securely tighten to guarantee seal contact.

4

Plug in the M8 control and load power supplies, verify polarity, seal all unused interfaces, and energize the system.

Loading product navigation…

How are the output channels grouped on the IP2042-B318 to handle thermal limits?

The 8 channels are split into three logical power groups: Channels 0 to 3 (sum maximum 4 A), Channels 4 and 5 (sum maximum 4 A), and Channels 6 and 7 (sum maximum 4 A). The total aggregate current limit across all channels must not exceed 12 A.

Does this module require a separate fieldbus T-junction connector?

No. The IP2042-B318 features an integrated B-coded M12 T-connector (1 x plug and 1 x socket), allowing direct PROFIBUS DP daisy-chaining without external T-pieces.

Can I use this module inside high-moisture or washdown environments?

Yes. This device features a rugged polyamide housing and is rated IP65/66/67, making it suitable for direct machine mounting in washdown zones, provided all unused ports are properly sealed.

What software can be used to configure the module's parameters?

The module can be configured either through the Beckhoff KS2000 commissioning software interface or directly via the network master controller using the appropriate GSD files and DP-V1 extensions.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...