1 dari 1

Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface

Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IP5009-B318

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Decentralized acquisition of high-frequency sensor data is directly enabled by the Beckhoff IP5009-B318, an IP67-rated PROFIBUS DP Fieldbus Box designed for harsh operating environments. This module interfaces absolute encoders or displacement sensors utilizing the SSI (Synchronous Serial Interface) protocol, transferring data directly to the higher-level master controller via PROFIBUS DP. With integrated B-coded M12 connections acting as a built-in T-connector, the module allows for direct bus line looping without requiring external active junctions. Configuration and parameters can be easily adjusted using the KS2000 software tool or directly via controller-driven DP-V1 acyclic slot communication.

Features

  • PROFIBUS DP Compatibility: Complete support for baud rates up to 12 Mbaud with integrated automatic speed detection.
  • Rugged Enclosure Design: Full IP65, IP66, and IP67 protection ratings, eliminating the need for protective control cabinets in the field.
  • Integrated Loop-Through: M12 male and female B-coded interfaces enable simple daisy-chaining of the fieldbus line.
  • Flexible Configuration: Supports DP-V1 communication extensions for dynamic, runtime parameter adjustments.
  • Reliable Power Distribution: Standardized M8 connectors for control voltage and downstream load distribution.

Applications

  • Decentralized SSI absolute encoder feedback in packaging and material handling systems.
  • High-accuracy position sensing on outdoor linear axes and heavy machinery.
  • Automotive assembly lines requiring direct, field-mounted sensor integration.
  • Wind turbine pitch control systems and waste-water treatment plants.

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number IP5009-B318
Fieldbus Protocol PROFIBUS DP (with DP-V1 support)
Data Transfer Rates Up to 12 Mbaud (automatic detection)
Fieldbus Interface 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded
Control Voltage Supply 24 V DC (-15% / +20%)
Current Consumption (Box Supply) 85 mA + sensor load (max. 0.5 A)
Power Feed / Downstream 1 x M8 male socket (4-pin) / 1 x M8 female socket (4-pin)
Isolation (Control / Fieldbus) None (electrical isolation is determined by sensor configuration)
Cycle Time Approx. 0.5 ms (for typical network of 10 boxes with 32-bit I/O each)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Approvals CE, UL
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Interface Connection Pin Number Signal Assignment
PROFIBUS DP M12 (B-coded) Pin 1 VP (+5 V DC for active termination)
Pin 2 RxD/TxD-N (A-line, Green)
Pin 3 DGND (Data Ground)
Pin 4 RxD/TxD-P (B-line, Red)
Pin 5 Shield
Power M8 (Feed Connection) Pin 1 +24 V DC control voltage (Us)
Pin 2 +24 V DC load voltage (Up)
Pin 3 GND (Us)
Pin 4 GND (Up)

Alternative Models & Compatibility

The IP5009-B318 replaces several legacy non-coupled configurations by bringing SSI decoding down to the machine level. Ensure your GSD file is updated to include the exact module parameters to prevent cyclic data exchange errors with older master systems. For setups utilizing the EtherCAT network topology rather than PROFIBUS, the EP5001-0002 serves as the native EtherCAT fieldbus equivalent.

Application Pitfalls & Engineering Notes

When daisy-chaining multiple boxes via the M8 power distribution interfaces, calculate the total voltage drop. The cumulative control current (Us) should not exceed 4 A across a single segment to prevent high thermal stress on the internal bus rails. Since control voltage and fieldbus communications do not share electrical isolation inside the module, run all system fieldbus lines in separated, shielded trays to prevent EMI-induced communication dropouts.

Commissioning & Wiring Tips

For optimal performance, use a terminating resistor if the IP5009-B318 acts as the physical last node in the PROFIBUS segment. Standard active termination can be accomplished using an M12 B-coded terminator connected to the downstream socket interface. Ensure the SSI sensor cable is shielded and connected directly to the designated housing shield collar to maintain signal integrity during dynamic motor acceleration cycles.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate all electrical power sources before initiating installation, removal, or wiring processes. Verify that both control and load voltages (Us and Up) are fully de-energized. Failure to strictly follow these safety steps can cause immediate physical danger or catastrophic failures to connected high-precision SSI sensors.

1

Mount the Fieldbus Box on a flat, vibration-free surface using two M4 mounting screws.

2

Securely torque the M12 B-coded PROFIBUS cable connectors to prevent moisture and dust ingress.

3

Wire the M8 power supply connection, ensuring polarity matches for both control (Us) and load (Up) segments.

4

Verify connection status and baud rate sync via the diagnostic LEDs prior to running system processes.

Loading product navigation…

What configuration tools are needed to set up the IP5009-B318?

Configuration can be achieved directly via the Beckhoff KS2000 software tool, or acyclically from your primary controller using DP-V1 PROFIBUS parameters.

Does this Fieldbus Box include integrated line termination?

No, it features a loop-through M12 B-coded connection. If placed at the end of the PROFIBUS line, an external M12 terminating resistor plug must be installed.

What is the maximum current limit for connected sensors?

The total sensor supply current is limited to a maximum of 0.5 A, in addition to the base box supply current of 85 mA.

Are the control voltage and fieldbus lines isolated from one another?

No. The IP5009-B318 does not feature electrical isolation between the control voltage input and the fieldbus communication circuit. Adequate field shielding is highly recommended.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...

Kilasan Masa Lalu: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...