1 dari 1

Delta Electronics DVS-110W02-3SFP DVS-110 Series Managed Industrial Ethernet Switch

Delta Electronics DVS-110W02-3SFP DVS-110 Series Managed Industrial Ethernet Switch

Hanya 10 item tersisa di stok
  • Produsen: Delta Electronics

  • Nomor Produk: DVS-110W02-3SFP

  • Negara asal:Amerika Serikat

  • Jenis Produk: Industrial Ethernet Switches

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Engineered for resilient deployment in rugged industrial environments, the Delta Electronics DVS-110W02-3SFP serves as a robust communications backbone featuring 7 Fast Ethernet ports and 3 Gigabit Ethernet combo ports. This managed switch optimizes critical industrial control loops by offering redundant dual-rate SFP slots alongside copper physical media, ensuring flexible fiber trunking across long distances. Encased in a rugged IP40 metal chassis, this device operates reliably across a wide temperature spectrum from -40 degC to 75 degC, matching the strict requirements of substation, wind power, and intelligent traffic management systems.

Key Features

  • Flexible Port Density: Incorporates 7 x 10/100Base-T(X) RJ45 copper ports and 3 x 10/100/1000Base-T / 100/1000Base-SFP combo ports.
  • Hardened Diagnostics: Dual digital inputs and dual relay outputs for immediate, on-site alarm notifications and system state integration.
  • Redundancy Mechanics: Supports redundant dual power inputs to preserve network status during primary source failures.
  • Industrial-Grade Enclosure: Heavy-duty IP40 metal housing provides superior heat dissipation and high electromagnetic immunity.
  • Advanced Management: Enables comprehensive ring redundancy, VLAN configuration, QoS priorities, and secure SNMP capabilities.

Applications

  • Substation automation and renewable energy SCADA collection nodes.
  • Traffic control cabinet systems requiring high operating temperature tolerances.
  • Water and wastewater plant networking utilizing distributed redundant PLC networks.
  • Factory floor automation with mixed copper-to-fiber industrial Ethernet networks.

Technical Specifications

Parameter Value
Manufacturer Delta Electronics
Model Number DVS-110W02-3SFP
Series DVS-110 Series
Copper RJ45 Ports 7 x 10/100Base-T(X), Auto MDI/MDI-X
Combo Ports 3 x 10/100/1000Base-T or 100/1000Base-SFP active dual-rate
Digital Inputs (DI) 2 x Dry Contact inputs (max state detection)
Digital Outputs (DO) 2 x Relay outputs (rated 1 A at 24 VDC)
Input Voltage Range Dual redundant 12 to 48 VDC terminal block inputs
Enclosure Protection IP40 metal case
Operating Temperature -40 degC to 75 degC
Storage Temperature -40 degC to 85 degC
Mounting Options DIN-rail mounting standard, optional wall mount
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal / Port Block Interface Assignment
Ports 1 to 7 10/100Base-T(X) RJ45 pins for local field devices
Ports 8 to 10 (Combo) Dual-purpose copper/fiber ports for Gigabit uplinks
Terminal Block (V1+, V1-) DC Primary Power Input (12 to 48 VDC)
Terminal Block (V2+, V2-) DC Backup/Redundant Power Input (12 to 48 VDC)
Terminal Block (DI1, DI2, DI COM) Digital Inputs for remote dry-contact sensor monitoring
Terminal Block (R1, R2) Relay contact outputs for automated trip/fault alerting

Empirical Engineering Insights

Alternative Models & Compatibility

The DVS-110W02-3SFP represents the premium high-availability model in the DVS-110 series. Unlike the non-SFP models (e.g., DVS-110W02), which rely solely on RJ45 copper uplinks, this variant supports mixed-mode topologies. If substituting for older series switches, ensure that the active SFP transceivers match the optical wavelength and distance limits of existing transceivers, as modern Delta firmware strictly monitors DDMI parameters and may report SFP diagnostic faults if mismatched or low-quality components are installed.

Application Pitfalls & Engineering Notes

While the DVS-110W02-3SFP switch functions perfectly up to 75 degC, operating near this limit inside unventilated, high-voltage control panels can accelerate the aging of internal electrolytic capacitors. To avoid localized thermal pockets, maintain at least 50 mm of vertical clearance above and below the switch chassis. Furthermore, standard-grade SFP transceivers can overheat and fail if run in environments exceeding 60 degC; always verify that installed transceivers are rated for extended industrial operating ranges.

Commissioning & Wiring Tips

To prevent operational ground loops, ground the switch's chassis directly to the field cabinet ground plate using a heavy gauge copper conductor connected to the protective earth screw on the switch's top block. Additionally, configure the SNMP alert thresholds within the switch's management utility during initial commissioning to capture dry-contact digital input changes, allowing immediate detection of physical cabinet door breaches or localized surge protection device (SPD) trips.

Installation Guidelines

CRITICAL WARNING

Verify that all incoming DC power lines are completely de-energized and locked out before wiring the terminal block connectors. Failure to isolate power can result in transient electric arcing, causing equipment damage or personal injury. Ensure the protective earth terminal is fully connected prior to completing any interface or power connection.

1
Mount the DVS-110W02-3SFP onto a standard 35 mm symmetric DIN rail, securing it with the rear-integrated spring-locked mounting bracket.
2
Connect the functional/protective earth terminal from the top of the switch body directly to the cabinet ground bar using a low-impedance copper wire.
3
Insert the stripped power conductors into the terminal block plug, secure the screw terminals, and plug the block into the switch (V1 and V2 for redundant topologies).
4
Insert necessary RJ45 copper cables and matching SFP transceivers, confirming positive click-locking for all physical media links.
Loading product navigation…

Does the DVS-110W02-3SFP support both single-mode and multi-mode SFP transceivers?

Yes. The three SFP slots support both single-mode and multi-mode SFP fiber transceivers operating at 100 Mbps or 1000 Mbps line speeds.

What happens if one of the dual DC power inputs fails?

The switch switches transparently to the secondary power input without packet loss, and can trigger the integrated alarm relay to warn operators of the power drop.

Can the digital inputs on this switch monitor dry contacts?

Yes, the two integrated digital inputs are designed for dry contact connection to easily integrate enclosure door switches or alarm sensors.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...