Description

Engineered for high-precision speed and torque regulation in compact industrial systems, the Delta Electronics VFD055M21A micro drive provides versatile sensorless vector control within the reliable VFD-M Series framework. This module delivers robust control characteristics and features built-in Modbus serial communications for seamless integration into distributed control networks. Featuring a highly efficient heat-dissipation design and a user-friendly programming interface, this drive balances heavy-duty performance with a compact physical footprint, making it ideal for automated manufacturing lines, fan networks, and conveying equipment.

Features

  • Advanced Control Algorithms: Features dual sensorless vector and adjustable V/F curve profiles for high starting torque and precise velocity control.
  • Broad Carrier Frequency Range: Adjustable carrier frequency from 1 to 15 kHz to minimize acoustic motor noise and optimize system efficiency.
  • Integrated Communication: Built-in RS-485 communication port supporting standard Modbus RTU/ASCII protocols for clean system integration.
  • Dynamic Braking: Built-in braking chopper allows direct connection of an external braking resistor for rapid deceleration and stopping.
  • Automated Tuning: Features intelligent auto-tuning capabilities to match motor winding parameters for optimal torque delivery.

Applications

  • High-speed packaging and filling machinery requiring rapid acceleration/deceleration.
  • Conveyor and material handling systems with varying payload demands.
  • Industrial fan systems and centrifugal pump operations.
  • Precision woodworking equipment and small machine tool spindles.

Technical Specifications

Manufacturer Delta Electronics
Model Number VFD055M21A
Series VFD-M Series
Rated Output Capacity 3.8 kVA
Rated Output Current 10 A
Maximum Output Voltage 3-phase, proportional to input voltage
Output Frequency Range 0.1 to 400 Hz
Carrier Frequency 1 to 15 kHz
Rated Input Power Supply Single-phase / 3-phase, 200 to 240 VAC, 50/60 Hz
Input Voltage Tolerance +/- 10% (180 to 264 VAC)
Input Frequency Tolerance +/- 5% (47 to 63 Hz)
Cooling Method Forced Fan Cooling
Net Weight 3.2 kg
Shipping Weight (Calculated) 5.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The VFD055M21A is standard within the VFD-M series legacy portfolio. When substituting this unit, closely match the input phase configurations. While this unit can accept both single-phase and three-phase 230V power inputs, utilizing single-phase power requires careful sizing verification of downstream branch protection circuit breakers to handle the higher input line currents (up to 27 A in single-phase applications under high load conditions).

Application Pitfalls & Engineering Notes

Single-phase incoming power subjects the internal DC link bus capacitors to elevated thermal stress and increased ripple current. Ensure that the drive is operated strictly within the rated 10 A continuous output threshold when powered via a single-phase supply. Maintain side clearances of at least 50 mm when panel-mounting multiple drives in close proximity to prevent hot spots from triggering an over-temperature fault (oH).

Commissioning & Wiring Tips

Always route the control signal wires (AVI, ACI, and digital control terminals) through a dedicated, shielded conduit separate from the high-power AC supply input (R, S, T) and motor output (U, V, W) lines. Ensure that control common (GND) is not bonded directly to the frame earth ground; the physical chassis earth terminal must be connected to a dedicated, low-impedance ground point (under 100 ohms) to avoid high-frequency noise interference on analog inputs.

Installation Guidelines

CRITICAL SAFETY WARNING: De-energize all incoming power lines prior to opening the drive wiring cover. After disconnecting supply power, wait a minimum of 10 minutes to allow the DC bus capacitors to fully discharge. Use a reliable digital multimeter to verify that DC voltage between the + and - terminals is under 36 VDC before initiating any installation, terminal tightening, or wiring procedures.
1

Mount the VFD055M21A drive vertically to a flat, non-flammable backplate within a dust-free, dry enclosure, ensuring adequate clearance above and below for standard convective airflow.

2

Connect the single-phase (or three-phase) AC input power lines exclusively to terminals R and S (or R, S, T). Never apply mains voltage to the motor terminals U, V, or W, as this will result in immediate and catastrophic module damage.

3

Route shielded, low-capacitance motor cabling between terminals U, V, W and the motor stator terminals. Ensure both the motor frame and the drive ground terminal are securely bonded to a unified system ground bus.

4

Verify that all control loop terminations (e.g., potentiometer connections or Modbus communication wires) are secure, replace the cover plate, power up the system, and perform an initial motor auto-tune sequence before applying operational mechanical loads.

Can the VFD055M21A drive accept a three-phase input supply?

Yes, although it is designated as a single-phase drive (code 21), it is designed and rated to accept either single-phase or three-phase input power in the 200 to 240 VAC voltage class.

What is the maximum output frequency rating of this VFD?

The drive supports an output frequency range of 0.1 to 400 Hz, making it suitable for high-speed motor and spindle applications.

Does this model have a built-in braking resistor or chopper?

The VFD055M21A features a built-in dynamic braking chopper. It does not contain an internal braking resistor; you must connect an external braking resistor across the B1 and B2 terminals for applications requiring high deceleration rates.

How do I resolve an oC (Overcurrent) fault on startup?

Check the acceleration time parameter and increase it if necessary. If the fault persists, verify that the motor stator windings match the drive rating, ensure the motor cable shield is correctly grounded, and run a motor auto-tune.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...

Kilasan Masa Lalu: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...