GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay

GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay

Hanya 3 item tersisa di stok
  • Produsen: General Electric

  • Nomor Produk: SR750-P5-G5-HI-A20-R

  • Negara asal:Amerika Serikat

  • Jenis Produk: Feeder Management Relay

  • Kode batang: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 8500g

  • Dimensi: 220 mm x 275 mm x 300 mm (W x H x D)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

GE Vernova Multilin 750 Feeder Management Relay is a digital system intended for the comprehensive management, primary protection, and control of distribution feeders. Designed without automatic recloser functionality to distinguish it from the 760 series, this relay provides robust backup protection for buses, transformers, and transmission lines within a convenient draw-out construction. Equipped with full metering capabilities and analog input/output options, it ensures high asset visibility and integrates into monitoring and control infrastructures.

Description

The GE Multilin 750-P5-G5-HI-A20-R is an industrialized protection system tailored for distribution feeders on solidly grounded, high-impedance grounded, or resonant grounded networks. The unit features dedicated 5 A phase current inputs and 5 A zero-sequence ground current inputs to accommodate specific fault detection profiles. Operating under a wide high-voltage control power range, the relay incorporates an independent eight-channel 4 to 20 mA analog output array alongside a front-panel red breaker closed LED indicator. By utilizing standard industrial protocols and options for serial and Ethernet physical layers, the Multilin 750 executes fast fault processing, interlocking, and status reporting to optimize substation automation and protect upstream transformers and distribution buses.

Features

  • Complete protection suite containing phase, neutral, ground, and negative sequence instantaneous and time overcurrent elements.
  • Comprehensive ground protection capabilities via 5 A zero-sequence ground current inputs paired with neutral and ground overcurrent diagnostics.
  • High-voltage universal power supply options supporting both AC and DC industrial stations.
  • Integrated analog output hardware supplying eight independent 4 to 20 mA channels for remote PLC or SCADA tracking.
  • Standard front panel red LED indicator for distinct local breaker closed status confirmation.
  • Draw-out construction type enabling quick chassis maintenance and minimized replacement downtime.
  • Built-in diagnostic testing system featuring simulation modes to preview fault, pre-fault, and post-fault characteristics.

Applications

  • Primary protection and control for distribution feeders on solidly grounded, high-impedance grounded, or resonant (Peterson Coil) systems.
  • Bus blocking and interlocking protection coordination schemes.
  • High-speed fault detection for arc flash mitigation.
  • Voltage and frequency element-based automatic load shedding schemes.
  • Backup protection for transmission lines, feeders, distribution buses, and power transformers.

Ordering Information

Selection Code Description
750 Base Model: Feeder Management Relay (Without Autoreclose)
P5 Phase Current Inputs: 5 A secondary
G5 Ground Current Inputs: 5 A zero sequence
HI Power Supply: 88 to 300 VDC, 70 to 265 VAC @ 48 to 62 Hz
A20 Analog Outputs: Eight 4 to 20 mA analog outputs
R Breaker Status LED: Red breaker closed LED

 

Technical Specifications

Parameter Specification
Manufacturer GE Vernova
Base Series 750 Series Feeder Management Relay
Phase Current Input (P5) 5 A current transformer (CT) secondary input
Zero Sequence Current Input (G5) 5 A zero sequence current input
Control Power Supply Options (HI) 88 to 300 VDC, or 70 to 265 VAC @ 48 to 62 Hz
Analog Outputs (A20) Eight 4 to 20 mA analog outputs
Breaker Status LED (R) Red breaker closed LED
Phase/Neutral/Ground TOC Pickup Level 0.05 to 20.00 x CT in steps of 0.01
TOC Curve Shapes ANSI Extremely/Very/Moderately/Normally Inverse; Definite Time; IEC Curve A/B/C and Short; FlexCurve A/B; IAC Extreme/Very/Inverse/Short
IOC Delay Accuracy 0 to +20 ms (at non-zero time delay)
Frequency Range 16 to 65 Hz
Frequency Accuracy ±0.02 Hz
Current Metering Accuracy ±0.5% of full scale
Voltage Metering Accuracy 0.25% of full scale

 

Installation Guidelines

  • Mounting: Ensure proper panel mounting alignment matching standard draw-out dimensions. Keep clearance optimized for ventilation.
  • Grounding: Establish a dedicated low-impedance ground connection at the chassis ground terminal before making any current transformer or control power connections.
  • CT Wiring: Verify secure insertion into the automatic shorting terminals. Phase and ground inputs must match the specified 5 A primary or secondary CT ratios to prevent overcurrent saturation or measurement inaccuracies.
  • Control Power Protection: Route lines through an external fuse or circuit breaker matching the HI voltage limits (88 to 300 VDC or 70 to 265 VAC) to avoid power circuit component failure.
  • Shielding: Ground the communication line shields at the PLC or computer side only to prevent ground loop interference.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay

What is the primary difference between the 750 and 760 series relays?

The 750 series serves as a feeder management relay without automatic recloser functionality, whereas the 760 series includes a built-in 4-shot recloser mechanism.

What power ranges are supported by the HI control supply designation?

The HI option supports a high-voltage input range of 88 to 300 VDC or 70 to 265 VAC at frequencies between 48 and 62 Hz.

What analog signaling range does the A20 suffix specify for this unit?

The A20 designation equips the device with eight independent 4 to 20 mA analog output channels suitable for standard instrumentation loops.

Can the current transformer inputs accept 1 A secondary ratings directly?

No, the P5 and G5 hardware designations explicitly configure the phase and ground current channels for 5 A secondary current transformer connections.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan untuk Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...