Product Description

Description

The BECKHOFF BK9105 is an EtherNet/IP Bus Coupler designed to connect EtherNet/IP networks to the modular Beckhoff Bus Terminals. Acting as the head station of an electronic terminal block, the coupler converts telegrams from the higher-level fieldbus system into the bit-level signals of the internal Bus Terminals. The BK9105 features an integrated 2-channel switch with two RJ45 interfaces, enabling implementation in line topologies without requiring additional external switches.

This bus coupler supports up to 64 Bus Terminals directly, which can be expanded up to 255 terminals using K-bus extension technology. It handles up to 492 bytes of input data and 492 bytes of output data over EtherNet/IP. Configuration and parameterization of the connected I/O stations are managed via the KS2000 configuration software or through the controller using standard configuration tools. The unit is powered by a 24 V DC supply and provides internal current to the K-bus to support connected system terminals.

Features

  • Connects EtherNet/IP networks to modular BECKHOFF Bus Terminals
  • Integrated 2-channel switch with 2 x RJ45 ports for line and star wiring topologies
  • Supports up to 64 Bus Terminals natively, extendable up to 255 terminals via K-bus extension
  • Process data communication up to 492 bytes input and 492 bytes output
  • Automatic detection of 10/100 Mbit/s transmission rates
  • Configurable via KS2000 software
  • Electrical isolation across power contacts, supply voltage, and fieldbus interfaces

Applications

  • Distributed industrial automation and machine control architectures
  • Modular machine building requiring flexible I/O expansion via EtherNet/IP
  • EtherNet/IP network node integration for digital and analog sensor/actuator arrays
  • Process and factory automation lines utilizing line or star Ethernet topologies

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model BK9105
Product Type EtherNet/IP Bus Coupler
Country of Origin Germany

Communication and Fieldbus

Parameter Specification
Protocol EtherNet/IP
Data transfer rates 10/100 Mbit/s (automatic recognition)
Bus interface 2 x RJ45 (2-channel switch)
Data transfer medium 4 x 2 twisted pair copper cable; category 3 (10 Mbit/s), category 5 (100 Mbit/s)
Max. fieldbus data 492 byte input and 492 byte output
Topology Line or star wiring
Cascading Up to 20 BK9103 or max. line length 2 km
Distance between stations 100 m between hub/switch and bus coupler or between bus coupler and bus coupler

Terminal and I/O Capacity

Parameter Specification
Number of Bus Terminals 64 (255 with K-bus extension)
Digital peripheral signals 3,936 inputs/outputs
Analog peripheral signals 122 inputs/outputs

Electrical

Parameter Specification
Power supply 24 V DC (-15 % / +20 %)
Input current 70 mA + (total K-bus current)/4, 500 mA max.
Starting current 2.5 x continuous current
Recommended fuse ≤ 10 A
Current supply K-bus 1750 mA
Power contacts Max. 24 V DC / max. 10 A
Electrical isolation 500 V (power contact / supply voltage / fieldbus)

Mechanical and Environmental

Parameter Specification
Weight Approx. 170 g
Operating temperature -25 to +60 degC
Storage temperature -40 to +85 degC
Relative humidity 95 %, no condensation
Vibration/shock resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC immunity/emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection rating IP20
Installation position Variable

Installation Guidelines

  1. Ensure all power supplies are switched off and isolated before beginning installation or wiring work.
  2. Verify that the mounting rail is securely installed and free from debris.
  3. Mount the BECKHOFF BK9105 Bus Coupler onto the DIN rail by clipping it into position according to mechanical layout guidelines.
  4. Attach downstream Bus Terminals in the correct sequence, ensuring the K-bus connections and power contacts latch properly.
  5. Connect the 24 V DC power supply and system ground to the designated terminals, verifying voltage levels and polarity.
  6. Connect the Ethernet cables to the RJ45 ports for integration into the EtherNet/IP network.
  7. Power on the system and verify operational status via the diagnostic LEDs before commissioning the network configuration.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF BK9105?
The BECKHOFF BK9105 functions as an EtherNet/IP Bus Coupler that connects an EtherNet/IP network to modular BECKHOFF Bus Terminals, translating fieldbus telegrams into internal K-bus signals.
How many Bus Terminals can be connected to the BK9105?
The BECKHOFF BK9105 supports up to 64 Bus Terminals directly, and this capacity can be expanded up to 255 Bus Terminals utilizing K-bus extension technology.
What network interface does the BK9105 use?
The BECKHOFF BK9105 is equipped with two RJ45 ports configured as an integrated 2-channel switch, allowing for straightforward line or star network topologies without external switches.
What power supply requirements does the BK9105 need?
The BECKHOFF BK9105 operates on a 24 V DC power supply (-15% / +20%) and provides up to 1750 mA current supply to the internal K-bus for connected terminals.
Reviews

BK9105

Stock & lead time on request

Call
1 su 1

BECKHOFF BK9105 EtherNet/IP Bus Coupler

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: BK9105

  • Country of origin:Germany

  • Product Type: Bus Coupler

  • Payment: T/T, Western Union

  • Weight: 170g

  • Dimensions: 10 x 5 x 3 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF BK9105 is an EtherNet/IP Bus Coupler designed to connect EtherNet/IP networks to the modular Beckhoff Bus Terminals. Acting as the head station of an electronic terminal block, the coupler converts telegrams from the higher-level fieldbus system into the bit-level signals of the internal Bus Terminals. The BK9105 features an integrated 2-channel switch with two RJ45 interfaces, enabling implementation in line topologies without requiring additional external switches.

This bus coupler supports up to 64 Bus Terminals directly, which can be expanded up to 255 terminals using K-bus extension technology. It handles up to 492 bytes of input data and 492 bytes of output data over EtherNet/IP. Configuration and parameterization of the connected I/O stations are managed via the KS2000 configuration software or through the controller using standard configuration tools. The unit is powered by a 24 V DC supply and provides internal current to the K-bus to support connected system terminals.

Features

  • Connects EtherNet/IP networks to modular BECKHOFF Bus Terminals
  • Integrated 2-channel switch with 2 x RJ45 ports for line and star wiring topologies
  • Supports up to 64 Bus Terminals natively, extendable up to 255 terminals via K-bus extension
  • Process data communication up to 492 bytes input and 492 bytes output
  • Automatic detection of 10/100 Mbit/s transmission rates
  • Configurable via KS2000 software
  • Electrical isolation across power contacts, supply voltage, and fieldbus interfaces

Applications

  • Distributed industrial automation and machine control architectures
  • Modular machine building requiring flexible I/O expansion via EtherNet/IP
  • EtherNet/IP network node integration for digital and analog sensor/actuator arrays
  • Process and factory automation lines utilizing line or star Ethernet topologies

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model BK9105
Product Type EtherNet/IP Bus Coupler
Country of Origin Germany

Communication and Fieldbus

Parameter Specification
Protocol EtherNet/IP
Data transfer rates 10/100 Mbit/s (automatic recognition)
Bus interface 2 x RJ45 (2-channel switch)
Data transfer medium 4 x 2 twisted pair copper cable; category 3 (10 Mbit/s), category 5 (100 Mbit/s)
Max. fieldbus data 492 byte input and 492 byte output
Topology Line or star wiring
Cascading Up to 20 BK9103 or max. line length 2 km
Distance between stations 100 m between hub/switch and bus coupler or between bus coupler and bus coupler

Terminal and I/O Capacity

Parameter Specification
Number of Bus Terminals 64 (255 with K-bus extension)
Digital peripheral signals 3,936 inputs/outputs
Analog peripheral signals 122 inputs/outputs

Electrical

Parameter Specification
Power supply 24 V DC (-15 % / +20 %)
Input current 70 mA + (total K-bus current)/4, 500 mA max.
Starting current 2.5 x continuous current
Recommended fuse ≤ 10 A
Current supply K-bus 1750 mA
Power contacts Max. 24 V DC / max. 10 A
Electrical isolation 500 V (power contact / supply voltage / fieldbus)

Mechanical and Environmental

Parameter Specification
Weight Approx. 170 g
Operating temperature -25 to +60 degC
Storage temperature -40 to +85 degC
Relative humidity 95 %, no condensation
Vibration/shock resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC immunity/emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection rating IP20
Installation position Variable

Installation Guidelines

  1. Ensure all power supplies are switched off and isolated before beginning installation or wiring work.
  2. Verify that the mounting rail is securely installed and free from debris.
  3. Mount the BECKHOFF BK9105 Bus Coupler onto the DIN rail by clipping it into position according to mechanical layout guidelines.
  4. Attach downstream Bus Terminals in the correct sequence, ensuring the K-bus connections and power contacts latch properly.
  5. Connect the 24 V DC power supply and system ground to the designated terminals, verifying voltage levels and polarity.
  6. Connect the Ethernet cables to the RJ45 ports for integration into the EtherNet/IP network.
  7. Power on the system and verify operational status via the diagnostic LEDs before commissioning the network configuration.
Loading product navigation…

What is the primary function of the BECKHOFF BK9105?

The BECKHOFF BK9105 functions as an EtherNet/IP Bus Coupler that connects an EtherNet/IP network to modular BECKHOFF Bus Terminals, translating fieldbus telegrams into internal K-bus signals.

How many Bus Terminals can be connected to the BK9105?

The BECKHOFF BK9105 supports up to 64 Bus Terminals directly, and this capacity can be expanded up to 255 Bus Terminals utilizing K-bus extension technology.

What network interface does the BK9105 use?

The BECKHOFF BK9105 is equipped with two RJ45 ports configured as an integrated 2-channel switch, allowing for straightforward line or star network topologies without external switches.

What power supply requirements does the BK9105 need?

The BECKHOFF BK9105 operates on a 24 V DC power supply (-15% / +20%) and provides up to 1750 mA current supply to the internal K-bus for connected terminals.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosi degli alimentatori da 24 V CC senza inseguire guasti fantasma

Un quadro di controllo inattivo non significa automaticamente che l’alimentatore sia guasto. Questa guida sul campo utilizza controlli dell’ingresso, a vuoto, sotto carico, dell’ondulazione, del...

Una catena di segnali pratica per la misurazione e il controllo industriali

Un controllo affidabile inizia prima che il PLC esegua un ciclo. Questa guida di ingegneria segue la catena del segnale dal rilevamento e dal condizionamento fino alla trasmissione, all’azione di...

Modbus sulle reti di impianto: frame, registri e limiti di progettazione

Modbus è ancora ampiamente utilizzato perché il suo modello dati è semplice, non perché ogni implementazione lo sia. Questa guida spiega i frame, la mappatura dei registri, la temporizzazione, la...

All'interno della CPU del PLC: cicli di scansione, memoria e selezione

Una guida pratica di ingegneria al funzionamento della CPU di un PLC, dai cicli di scansione deterministici e dalle tabelle delle immagini degli I/O fino a memoria, comunicazioni, diagnostica,...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.