BECKHOFF

BECKHOFF EL3062-0030 EtherCAT Terminal 2-channel Analog Input Terminal

SKU EL3062-0030

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EL3062-0030
  • Origin Germany
  • Product Type: Analog Input Terminals
  • Payment: T/T, Western Union
  • Weight: 1.5 kg
  • Dimensions: 10 cm x 1.5 cm x 7 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Processing standard single-ended analog signals in industrial automation systems is efficiently handled by the EL3062-0030. This robust analog input terminal operates within the 0 V to +10 V voltage range, digitizing incoming signals with a high-performance 12-bit resolution for transmission to the master control system. Engineered for seamless integration with the Beckhoff EtherCAT Terminal system, it combines high-speed communication via the internal E-bus with galvanic safety features. Compact and highly reliable, it is ideal for standard control applications requiring fast, noise-immune signal acquisition.

Features

  • Dual single-ended analog inputs configured for 0 V to +10 V signal ranges.
  • Digitization resolution of 12 bits with a 16-bit representation format.
  • Typical conversion time of 0.625 ms using the default 50 Hz internal filter.
  • Galvanic electrical isolation rated at 500 V between the E-bus and the field circuit.
  • Integrated 1 kHz input limit filter for high-frequency noise suppression.
  • Excellent electromagnetic compatibility complying with industrial emission and immunity standards.

Applications

This 2-channel analog input terminal is widely implemented across heavy industrial and manufacturing environments, including:

  • Machine control and process automation.
  • Continuous monitoring of industrial sensors and transmitters.
  • Factory automation lines requiring reliable 0-10 V analog data acquisition.
  • Test bench and laboratory instrumentation setups.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3062-0030
Product Type 2-channel Analog Input Terminal
Number of Inputs 2 (single-ended)
Signal Voltage Range 0 V to +10 V
Internal Resistance > 130 kOhm
Resolution 12 bit (16 bit presentation)
Conversion Time Typical 0.625 ms (default 50 Hz filter setting)
Input Filter Limit Frequency 1 kHz
Measuring Error (Full Range) < ± 0.30% (at 0 degC to +55 degC, relative to full scale); < ± 0.5% (extended temperature range)
Current Consumption via E-Bus Typical 130 mA
Electrical Isolation 500 V (E-bus / field voltage)
Dielectric Strength Max. 30 V
Permissible Relative Humidity 95%, non-condensing
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20
Dimensions (H x W x D) Approx. 10 cm x 1.5 cm x 7 cm
Shipping Weight 1.5 kg

Installation Guidelines

For safe and optimal performance of the terminal block, adhere to the following installation standards:

  • DIN Rail Mounting: Snap the terminal securely onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism engages properly with adjacent terminals.
  • Shielding and Grounding: To minimize high-frequency electromagnetic interference, use shielded signal cables and connect the shield directly to the mounting rail or grounding terminal.
  • Environmental Protection: Ensure the installation enclosure provides an IP54 or higher rating if operating in harsh, dust-heavy, or wet industrial environments, as the module itself is rated IP20.
  • Ventilation: Maintain standard vertical clearance above and below the terminal assembly to prevent thermal buildup and ensure reliable operation.

Compliance and Certifications

  • CE
  • EN 61000-6-2 (Electromagnetic compatibility - Immunity for industrial environments)
  • EN 61000-6-4 (Electromagnetic compatibility - Emission standard for industrial environments)
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the signal voltage range of the Beckhoff EL3062-0030?
The EL3062-0030 analog input terminal accepts single-ended signals ranging from 0 V to +10 V.
What is the electrical isolation capability of this terminal?
It provides galvanic electrical isolation of up to 500 V between the internal E-bus and the external field voltage.
Does the EL3062-0030 include input filtering?
Yes, it features an integrated input filter with a limit frequency of 1 kHz and a default 50 Hz filter configuration.
Reviews

EL3062-0030

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF EL3062-0030 EtherCAT Terminal 2-channel Analog Input Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3062-0030

  • Country of origin:Germany

  • Product Type: Analog Input Terminals

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 10 cm x 1.5 cm x 7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Processing standard single-ended analog signals in industrial automation systems is efficiently handled by the EL3062-0030. This robust analog input terminal operates within the 0 V to +10 V voltage range, digitizing incoming signals with a high-performance 12-bit resolution for transmission to the master control system. Engineered for seamless integration with the Beckhoff EtherCAT Terminal system, it combines high-speed communication via the internal E-bus with galvanic safety features. Compact and highly reliable, it is ideal for standard control applications requiring fast, noise-immune signal acquisition.

Features

  • Dual single-ended analog inputs configured for 0 V to +10 V signal ranges.
  • Digitization resolution of 12 bits with a 16-bit representation format.
  • Typical conversion time of 0.625 ms using the default 50 Hz internal filter.
  • Galvanic electrical isolation rated at 500 V between the E-bus and the field circuit.
  • Integrated 1 kHz input limit filter for high-frequency noise suppression.
  • Excellent electromagnetic compatibility complying with industrial emission and immunity standards.

Applications

This 2-channel analog input terminal is widely implemented across heavy industrial and manufacturing environments, including:

  • Machine control and process automation.
  • Continuous monitoring of industrial sensors and transmitters.
  • Factory automation lines requiring reliable 0-10 V analog data acquisition.
  • Test bench and laboratory instrumentation setups.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3062-0030
Product Type 2-channel Analog Input Terminal
Number of Inputs 2 (single-ended)
Signal Voltage Range 0 V to +10 V
Internal Resistance > 130 kOhm
Resolution 12 bit (16 bit presentation)
Conversion Time Typical 0.625 ms (default 50 Hz filter setting)
Input Filter Limit Frequency 1 kHz
Measuring Error (Full Range) < ± 0.30% (at 0 degC to +55 degC, relative to full scale); < ± 0.5% (extended temperature range)
Current Consumption via E-Bus Typical 130 mA
Electrical Isolation 500 V (E-bus / field voltage)
Dielectric Strength Max. 30 V
Permissible Relative Humidity 95%, non-condensing
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20
Dimensions (H x W x D) Approx. 10 cm x 1.5 cm x 7 cm
Shipping Weight 1.5 kg

Installation Guidelines

For safe and optimal performance of the terminal block, adhere to the following installation standards:

  • DIN Rail Mounting: Snap the terminal securely onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism engages properly with adjacent terminals.
  • Shielding and Grounding: To minimize high-frequency electromagnetic interference, use shielded signal cables and connect the shield directly to the mounting rail or grounding terminal.
  • Environmental Protection: Ensure the installation enclosure provides an IP54 or higher rating if operating in harsh, dust-heavy, or wet industrial environments, as the module itself is rated IP20.
  • Ventilation: Maintain standard vertical clearance above and below the terminal assembly to prevent thermal buildup and ensure reliable operation.

Compliance and Certifications

  • CE
  • EN 61000-6-2 (Electromagnetic compatibility - Immunity for industrial environments)
  • EN 61000-6-4 (Electromagnetic compatibility - Emission standard for industrial environments)

What is the signal voltage range of the Beckhoff EL3062-0030?

The EL3062-0030 analog input terminal accepts single-ended signals ranging from 0 V to +10 V.

What is the electrical isolation capability of this terminal?

It provides galvanic electrical isolation of up to 500 V between the internal E-bus and the external field voltage.

Does the EL3062-0030 include input filtering?

Yes, it features an integrated input filter with a limit frequency of 1 kHz and a default 50 Hz filter configuration.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.

Filtraggio con media mobile nei sistemi di controllo analogico DCS e PLC

Un filtro a media mobile è lo smussatore a finestra scorrevole che la maggior parte degli ingegneri della strumentazione inserisce nei percorsi dei segnali analogici di DCS e PLC. Ecco come funziona...