BECKHOFF

BECKHOFF EL6070-0033 EtherCAT Terminal

SKU EL6070-0033

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EL6070-0033
  • Origin Germany
  • Product Type: EtherCAT Terminal
  • Payment: T/T, Western Union
  • Weight: 1.0 kg
  • Dimensions: 12 mm x 100 mm x 68 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

The EL6070-0033 is a specialized EtherCAT Terminal serving as a hardware-based license key for TwinCAT 3.1 software. Engineered by BECKHOFF, this terminal securely stores and transmits license information via the EtherCAT network, enabling authorized use of specific TwinCAT 3 functionalities. Designed for reliability in industrial environments, the EL6070-0033 integrates seamlessly into existing EtherCAT configurations, providing a durable and tamper-resistant solution for software licensing management.

Features

  • License key terminal for TwinCAT 3.1
  • Factory-installed licenses
  • Secure transmission of license data over EtherCAT
  • Compact terminal housing (12 mm width)
  • Integrated signal LEDs for status monitoring
  • DIN rail mounting compatible with double slot and key connection for side-by-side assembly
  • Spring-loaded connection technology for easy wiring

Applications

  • TwinCAT 3.1 software license management
  • Industrial control systems requiring hardware-locked software licensing
  • EtherCAT-based automation environments requiring secure software activation

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model EL6070-0033
Current Consumption E-bus typ. 120 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.05 kg
Protection Rating IP20
Connection Cross-section s: 0.08 to 2.5 mm2, st: 0.08 to 2.5 mm2, f: 0.14 to 1.5 mm2
Stripping Length 8 to 9 mm
Current Load Power Contacts Imax: 10 A

Connections/Interfaces

Interface Type Function
EtherCAT Internal communication and license data transmission
Spring-loaded terminal Wiring for power/signal (if applicable)

Installation Guidelines

  • Install the unit on a 35 mm DIN rail (EN 60715) and secure it using the integrated lock.
  • Utilize the double slot and key connection for stable, side-by-side mounting.
  • Ensure all wiring is performed using the spring-loaded mechanism; use a screwdriver for actuation.
  • Maintain the operating ambient temperature between -25 and +60 degC.
  • Ensure installation is within an IP20-rated cabinet or housing to protect against moisture and contaminants.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • IECEx: Ex ec IIC T4 Gc
  • cFMus: Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx ec IIC T4 Gc
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

EL6070-0033

Stock & lead time on request

Call
1 su 1

BECKHOFF EL6070-0033 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL6070-0033

  • Country of origin:Germany

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

The EL6070-0033 is a specialized EtherCAT Terminal serving as a hardware-based license key for TwinCAT 3.1 software. Engineered by BECKHOFF, this terminal securely stores and transmits license information via the EtherCAT network, enabling authorized use of specific TwinCAT 3 functionalities. Designed for reliability in industrial environments, the EL6070-0033 integrates seamlessly into existing EtherCAT configurations, providing a durable and tamper-resistant solution for software licensing management.

Features

  • License key terminal for TwinCAT 3.1
  • Factory-installed licenses
  • Secure transmission of license data over EtherCAT
  • Compact terminal housing (12 mm width)
  • Integrated signal LEDs for status monitoring
  • DIN rail mounting compatible with double slot and key connection for side-by-side assembly
  • Spring-loaded connection technology for easy wiring

Applications

  • TwinCAT 3.1 software license management
  • Industrial control systems requiring hardware-locked software licensing
  • EtherCAT-based automation environments requiring secure software activation

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model EL6070-0033
Current Consumption E-bus typ. 120 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.05 kg
Protection Rating IP20
Connection Cross-section s: 0.08 to 2.5 mm2, st: 0.08 to 2.5 mm2, f: 0.14 to 1.5 mm2
Stripping Length 8 to 9 mm
Current Load Power Contacts Imax: 10 A

Connections/Interfaces

Interface Type Function
EtherCAT Internal communication and license data transmission
Spring-loaded terminal Wiring for power/signal (if applicable)

Installation Guidelines

  • Install the unit on a 35 mm DIN rail (EN 60715) and secure it using the integrated lock.
  • Utilize the double slot and key connection for stable, side-by-side mounting.
  • Ensure all wiring is performed using the spring-loaded mechanism; use a screwdriver for actuation.
  • Maintain the operating ambient temperature between -25 and +60 degC.
  • Ensure installation is within an IP20-rated cabinet or housing to protect against moisture and contaminants.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • IECEx: Ex ec IIC T4 Gc
  • cFMus: Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx ec IIC T4 Gc
Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...