BECKHOFF

BECKHOFF EP3184-0002 EtherCAT Box 4-Channel Analog Input Module

SKU EP3184-0002

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EP3184-0002
  • Origin Germany
  • Product Type: EtherCAT Modules
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The BECKHOFF EP3184-0002 EtherCAT Box is a 4-channel analog input module designed for harsh industrial environments requiring decentralized data acquisition. Featuring an IP65, IP66, and IP67 protection rating, this machine-mount module connects directly to the EtherCAT network via M8 sockets and acquires precise process signals without requiring a control cabinet.

This module processes four single-ended analog inputs, with each channel individually parameterizable for voltage or current signals ranging from -10/0 to +10 V or 0/4 to 20 mA. Operating with a 16-bit resolution including sign and support for distributed clocks, the EP3184-0002 delivers deterministic measurement timing for demanding automation and control applications.

Features

  • Four single-ended analog input channels parameterizable for voltage or current
  • Voltage ranges: -10/0 to +10 V; current ranges: 0/4 to 20 mA
  • High 16-bit resolution including sign for accurate signal acquisition
  • Integrated EtherCAT interface with dual shielded M8 sockets for line topology
  • Distributed clocks support for synchronized, time-precise measurements
  • Rugged fully potted plastic housing with IP65, IP66, and IP67 protection ratings
  • Sensor supply powered from the 24 V DC load supply voltage UP

Applications

  • Decentralized machine control systems without control cabinets
  • Industrial pressure, flow, and level monitoring using standard analog sensors
  • Automated test stands and measurement equipment requiring distributed data acquisition
  • Conveyor and handling systems operating in wet or dusty industrial environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EP3184-0002
Product Type EtherCAT Box
Protocol EtherCAT
Number of Inputs 4 (single-ended, 1 per socket)

Signal and I/O

Parameter Specification
Signal Type -10/0 to +10 V | 0/4 to 20 mA, parameterizable per channel
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Common-Mode Voltage UCM max. 35 V
Resolution 16 bit (incl. sign)
Measurement Error / Uncertainty < +-0.3 % (relative to full scale value)
Conversion Time ~ 100 us
Input Filter Limit Frequency 5 kHz
Input Filter Configurable
Distributed Clocks Yes

Electrical

Parameter Specification
Nominal Voltage 24 V DC (-15 % / +20 %)
Sensor Supply From load supply voltage UP
Current Consumption from US 120 mA
Electrical Isolation 500 V

Connections and Interfaces

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type
Input Connections 4 x M12 x 1, 5-pin, a-coded (1 per channel)
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin

Environmental and Mechanical

Parameter Specification
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Compliance and Certifications

Parameter Specification
Approvals and Markings CE, UL, ATEX
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. Ensure the system is completely de-energized before beginning mechanical or electrical installation.
  2. Verify that the mounting surface is clean and secure the EP3184-0002 module in the desired variable orientation using compatible machine screws.
  3. Connect the incoming EtherCAT network cable to the designated M8 bus socket and daisy-chain to downstream devices if applicable.
  4. Attach the 24 V DC system and load supply lines to the M8 power feed connectors, ensuring correct polarity and voltage tolerances.
  5. Wire analog sensors to the M12 a-coded input sockets, paying attention to shielding and correct pin assignments for voltage or current signal types.
  6. Verify all connections, secure screw locks on M8 and M12 connectors to maintain IP65/66/67 sealing, and restore power before commissioning via TwinCAT.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the BECKHOFF EP3184-0002?
The BECKHOFF EP3184-0002 is a decentralized 4-channel analog input module enclosed in an IP65, IP66, and IP67 rated EtherCAT Box housing for machine-level measurement applications.
What signal types does the EP3184-0002 support?
The BECKHOFF EP3184-0002 supports parameterizable input signals per channel, including -10/0 to +10 V voltage signals and 0/4 to 20 mA current signals.
What is the resolution of the analog inputs on the EP3184-0002?
The BECKHOFF EP3184-0002 features a 16-bit resolution including sign for high-precision analog data acquisition.
Does the EP3184-0002 support distributed clocks?
Yes, the BECKHOFF EP3184-0002 supports distributed clocks to ensure synchronized and time-deterministic data capture across the EtherCAT network.
What enclosure protection rating does the EP3184-0002 provide?
The BECKHOFF EP3184-0002 provides IP65, IP66, and IP67 protection ratings, enabling direct cabinet-free installation on machinery exposed to dust, water, and harsh industrial environments.
Reviews

EP3184-0002

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF EP3184-0002 EtherCAT Box 4-Channel Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP3184-0002

  • Country of origin:Germany

  • Product Type: EtherCAT Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF EP3184-0002 EtherCAT Box is a 4-channel analog input module designed for harsh industrial environments requiring decentralized data acquisition. Featuring an IP65, IP66, and IP67 protection rating, this machine-mount module connects directly to the EtherCAT network via M8 sockets and acquires precise process signals without requiring a control cabinet.

This module processes four single-ended analog inputs, with each channel individually parameterizable for voltage or current signals ranging from -10/0 to +10 V or 0/4 to 20 mA. Operating with a 16-bit resolution including sign and support for distributed clocks, the EP3184-0002 delivers deterministic measurement timing for demanding automation and control applications.

Features

  • Four single-ended analog input channels parameterizable for voltage or current
  • Voltage ranges: -10/0 to +10 V; current ranges: 0/4 to 20 mA
  • High 16-bit resolution including sign for accurate signal acquisition
  • Integrated EtherCAT interface with dual shielded M8 sockets for line topology
  • Distributed clocks support for synchronized, time-precise measurements
  • Rugged fully potted plastic housing with IP65, IP66, and IP67 protection ratings
  • Sensor supply powered from the 24 V DC load supply voltage UP

Applications

  • Decentralized machine control systems without control cabinets
  • Industrial pressure, flow, and level monitoring using standard analog sensors
  • Automated test stands and measurement equipment requiring distributed data acquisition
  • Conveyor and handling systems operating in wet or dusty industrial environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EP3184-0002
Product Type EtherCAT Box
Protocol EtherCAT
Number of Inputs 4 (single-ended, 1 per socket)

Signal and I/O

Parameter Specification
Signal Type -10/0 to +10 V | 0/4 to 20 mA, parameterizable per channel
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Common-Mode Voltage UCM max. 35 V
Resolution 16 bit (incl. sign)
Measurement Error / Uncertainty < +-0.3 % (relative to full scale value)
Conversion Time ~ 100 us
Input Filter Limit Frequency 5 kHz
Input Filter Configurable
Distributed Clocks Yes

Electrical

Parameter Specification
Nominal Voltage 24 V DC (-15 % / +20 %)
Sensor Supply From load supply voltage UP
Current Consumption from US 120 mA
Electrical Isolation 500 V

Connections and Interfaces

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type
Input Connections 4 x M12 x 1, 5-pin, a-coded (1 per channel)
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin

Environmental and Mechanical

Parameter Specification
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Compliance and Certifications

Parameter Specification
Approvals and Markings CE, UL, ATEX
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. Ensure the system is completely de-energized before beginning mechanical or electrical installation.
  2. Verify that the mounting surface is clean and secure the EP3184-0002 module in the desired variable orientation using compatible machine screws.
  3. Connect the incoming EtherCAT network cable to the designated M8 bus socket and daisy-chain to downstream devices if applicable.
  4. Attach the 24 V DC system and load supply lines to the M8 power feed connectors, ensuring correct polarity and voltage tolerances.
  5. Wire analog sensors to the M12 a-coded input sockets, paying attention to shielding and correct pin assignments for voltage or current signal types.
  6. Verify all connections, secure screw locks on M8 and M12 connectors to maintain IP65/66/67 sealing, and restore power before commissioning via TwinCAT.
Loading product navigation…

What is the BECKHOFF EP3184-0002?

The BECKHOFF EP3184-0002 is a decentralized 4-channel analog input module enclosed in an IP65, IP66, and IP67 rated EtherCAT Box housing for machine-level measurement applications.

What signal types does the EP3184-0002 support?

The BECKHOFF EP3184-0002 supports parameterizable input signals per channel, including -10/0 to +10 V voltage signals and 0/4 to 20 mA current signals.

What is the resolution of the analog inputs on the EP3184-0002?

The BECKHOFF EP3184-0002 features a 16-bit resolution including sign for high-precision analog data acquisition.

Does the EP3184-0002 support distributed clocks?

Yes, the BECKHOFF EP3184-0002 supports distributed clocks to ensure synchronized and time-deterministic data capture across the EtherCAT network.

What enclosure protection rating does the EP3184-0002 provide?

The BECKHOFF EP3184-0002 provides IP65, IP66, and IP67 protection ratings, enabling direct cabinet-free installation on machinery exposed to dust, water, and harsh industrial environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.