BECKHOFF

BECKHOFF EPI4374-0002 IO-Link Box

SKU EPI4374-0002

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EPI4374-0002
  • Origin Germany
  • Product Type: IO-Link Boxes
  • Payment: T/T, Western Union
  • Weight: 0.165 kg
  • Dimensions: 30 mm x 126 mm x 26.5 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The BECKHOFF EPI4374-0002 is a decentralized, combined analog I/O module designed for integration with IO-Link master systems. It offers an efficient solution for collecting and outputting analog signals directly at the machine level, eliminating the need for extensive wiring and protective enclosures. Operating under the IO-Link Specification V1.1 (Class B), this module establishes point-to-point communication with an upstream master to process signals with high precision.

This IO-Link box is equipped with two analog inputs and two analog outputs, all of which are parameterizable per channel. Engineers can configure each connection individually to operate with standard voltage signals (-10 to +10 V or 0 to 10 V) or current signals (0 to 20 mA or 4 to 20 mA). This flexible architecture permits the direct connection of diverse industrial sensors and actuators within a single hardware footprint.

Constructed with a robust polyamide (PA6) housing, the BECKHOFF EPI4374-0002 features an IP65, IP66, and IP67 protection rating. This design allows for direct mounting on machine frames in harsh industrial environments, ensuring resistance against moisture, dust, and mechanical stress while optimizing field installation layouts.

Features

  • Combination module with 2 analog inputs and 2 analog outputs in a single unit.
  • Individually parameterizable channels for voltage (-10/0...+10 V) or current (0/4...20 mA) signals.
  • 16-bit analog-to-digital and digital-to-analog resolution (including sign) for high measurement accuracy.
  • High-speed IO-Link communication operating at 230.4 kbaud (COM3).
  • Conforms to the IO-Link Specification V1.1, utilizing a Class B connection interface.
  • Durable, direct-mount housing rated to IP65/66/67 standards.
  • M12 connection technology for secure, screw-type field connections.

Applications

  • Decentralized signal acquisition and control in machine tool construction.
  • Direct field connection of analog pressure, temperature, and level sensors.
  • Local actuator control, such as modulating valves and variable speed drives, without cabinet space.
  • Testing and validation systems requiring modular, IP67-rated analog interface distribution.

Technical Specifications

General Specs
Manufacturer BECKHOFF
Model EPI4374-0002
Housing Material PA6 (Polyamide)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation 2 fixing holes, 3.5 mm diameter (for M3 screws)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Weight Approx. 165 g
Approvals CE, UL
IO-Link and Communication
Protocol IO-Link
Specification Version IO-Link V1.1, Class B
Data Transfer Rates 230.4 kbaud (COM3)
Interface Connection 1 x M12 plug, A-coded
Analog Signal Specifications
Number of Channels 2 analog inputs + 2 analog outputs
Signal Types -10/0...+10 V | 0/4...20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Input Filter Limit Frequency 5 kHz
Conversion Time (Inputs) ~100 microseconds
Conversion Time (Outputs) ~40 microseconds
Measurement Uncertainty < 0.1% (relative to full scale value)
Load Impedance (Voltage Output) > 5 kOhm
Load Impedance (Current Output) < 500 Ohm
Internal Resistance (Input) Voltage: > 200 kOhm | Current: typ. 85 Ohm + diode voltage
Electrical Data
Current Consumption Typ. 100 mA from L+
Electrical Isolation L+/P24: Yes
I/O Connections M12, screw type

Installation Guidelines

  1. Verify Model Details: Confirm that the unit is a BECKHOFF EPI4374-0002 and matches the system network plan before beginning installation.
  2. De-energize the System: Ensure all power supplies to the IO-Link master, actuator lines, and sensor devices are disconnected and locked out.
  3. Mechanical Mounting: Secure the IO-Link box to a flat mounting surface or machine frame using two M3 screws through the 3.5 mm integrated mounting holes. Ensure the mounting position supports mechanical stability and access to cables.
  4. Connect IO-Link Master: Attach the IO-Link Class B cable to the M12 interface plug. Verify that the cable is A-coded and correctly secured to maintain the IP protection rating.
  5. Wire Field Inputs and Outputs: Thread the M12 sensor and actuator connections carefully into the corresponding I/O ports. Tighten the screw connections to ensure reliable electrical contact and seal integrity.
  6. Configure Channel Parameters: Power on the system and use your TwinCAT or third-party engineering environment to configure the signal types (voltage or current) for each channel on the device.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What signal types does the BECKHOFF EPI4374-0002 support?
The BECKHOFF EPI4374-0002 supports both voltage and current signals, specifically -10 to +10 V, 0 to 10 V, 0 to 20 mA, and 4 to 20 mA. Each of the 2 analog input and 2 analog output channels is independently parameterizable.
What IO-Link specification and speed class does the BECKHOFF EPI4374-0002 use?
The BECKHOFF EPI4374-0002 is designed according to the IO-Link Specification V1.1 (Class B interface) and operates at a fast data transfer rate of 230.4 kbaud (COM3).
Does the BECKHOFF EPI4374-0002 require an industrial control cabinet?
No, the BECKHOFF EPI4374-0002 does not require a control cabinet. Its robust polyamide housing features an IP65/66/67 rating, which allows it to be mounted directly to machine frames in dusty, wet, or demanding physical environments.
What is the conversion speed and resolution of the BECKHOFF EPI4374-0002?
The BECKHOFF EPI4374-0002 features a high-accuracy 16-bit resolution (including sign). The typical conversion times are approximately 100 microseconds for the analog inputs and 40 microseconds for the analog outputs.
Is there electrical isolation on the BECKHOFF EPI4374-0002?
Yes, the BECKHOFF EPI4374-0002 features electrical isolation between the L+ sensor/logic power supply and the P24 actuator power supply lines.
Reviews

EPI4374-0002

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF EPI4374-0002 IO-Link Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPI4374-0002

  • Country of origin:Germany

  • Product Type: IO-Link Boxes

  • Payment: T/T, Western Union

  • Weight: 165g

  • Dimensions: 30 mm x 126 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF EPI4374-0002 is a decentralized, combined analog I/O module designed for integration with IO-Link master systems. It offers an efficient solution for collecting and outputting analog signals directly at the machine level, eliminating the need for extensive wiring and protective enclosures. Operating under the IO-Link Specification V1.1 (Class B), this module establishes point-to-point communication with an upstream master to process signals with high precision.

This IO-Link box is equipped with two analog inputs and two analog outputs, all of which are parameterizable per channel. Engineers can configure each connection individually to operate with standard voltage signals (-10 to +10 V or 0 to 10 V) or current signals (0 to 20 mA or 4 to 20 mA). This flexible architecture permits the direct connection of diverse industrial sensors and actuators within a single hardware footprint.

Constructed with a robust polyamide (PA6) housing, the BECKHOFF EPI4374-0002 features an IP65, IP66, and IP67 protection rating. This design allows for direct mounting on machine frames in harsh industrial environments, ensuring resistance against moisture, dust, and mechanical stress while optimizing field installation layouts.

Features

  • Combination module with 2 analog inputs and 2 analog outputs in a single unit.
  • Individually parameterizable channels for voltage (-10/0...+10 V) or current (0/4...20 mA) signals.
  • 16-bit analog-to-digital and digital-to-analog resolution (including sign) for high measurement accuracy.
  • High-speed IO-Link communication operating at 230.4 kbaud (COM3).
  • Conforms to the IO-Link Specification V1.1, utilizing a Class B connection interface.
  • Durable, direct-mount housing rated to IP65/66/67 standards.
  • M12 connection technology for secure, screw-type field connections.

Applications

  • Decentralized signal acquisition and control in machine tool construction.
  • Direct field connection of analog pressure, temperature, and level sensors.
  • Local actuator control, such as modulating valves and variable speed drives, without cabinet space.
  • Testing and validation systems requiring modular, IP67-rated analog interface distribution.

Technical Specifications

General Specs
Manufacturer BECKHOFF
Model EPI4374-0002
Housing Material PA6 (Polyamide)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation 2 fixing holes, 3.5 mm diameter (for M3 screws)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Weight Approx. 165 g
Approvals CE, UL
IO-Link and Communication
Protocol IO-Link
Specification Version IO-Link V1.1, Class B
Data Transfer Rates 230.4 kbaud (COM3)
Interface Connection 1 x M12 plug, A-coded
Analog Signal Specifications
Number of Channels 2 analog inputs + 2 analog outputs
Signal Types -10/0...+10 V | 0/4...20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Input Filter Limit Frequency 5 kHz
Conversion Time (Inputs) ~100 microseconds
Conversion Time (Outputs) ~40 microseconds
Measurement Uncertainty < 0.1% (relative to full scale value)
Load Impedance (Voltage Output) > 5 kOhm
Load Impedance (Current Output) < 500 Ohm
Internal Resistance (Input) Voltage: > 200 kOhm | Current: typ. 85 Ohm + diode voltage
Electrical Data
Current Consumption Typ. 100 mA from L+
Electrical Isolation L+/P24: Yes
I/O Connections M12, screw type

Installation Guidelines

  1. Verify Model Details: Confirm that the unit is a BECKHOFF EPI4374-0002 and matches the system network plan before beginning installation.
  2. De-energize the System: Ensure all power supplies to the IO-Link master, actuator lines, and sensor devices are disconnected and locked out.
  3. Mechanical Mounting: Secure the IO-Link box to a flat mounting surface or machine frame using two M3 screws through the 3.5 mm integrated mounting holes. Ensure the mounting position supports mechanical stability and access to cables.
  4. Connect IO-Link Master: Attach the IO-Link Class B cable to the M12 interface plug. Verify that the cable is A-coded and correctly secured to maintain the IP protection rating.
  5. Wire Field Inputs and Outputs: Thread the M12 sensor and actuator connections carefully into the corresponding I/O ports. Tighten the screw connections to ensure reliable electrical contact and seal integrity.
  6. Configure Channel Parameters: Power on the system and use your TwinCAT or third-party engineering environment to configure the signal types (voltage or current) for each channel on the device.
Loading product navigation…
Key Features:

What signal types does the BECKHOFF EPI4374-0002 support?

The BECKHOFF EPI4374-0002 supports both voltage and current signals, specifically -10 to +10 V, 0 to 10 V, 0 to 20 mA, and 4 to 20 mA. Each of the 2 analog input and 2 analog output channels is independently parameterizable.

What IO-Link specification and speed class does the BECKHOFF EPI4374-0002 use?

The BECKHOFF EPI4374-0002 is designed according to the IO-Link Specification V1.1 (Class B interface) and operates at a fast data transfer rate of 230.4 kbaud (COM3).

Does the BECKHOFF EPI4374-0002 require an industrial control cabinet?

No, the BECKHOFF EPI4374-0002 does not require a control cabinet. Its robust polyamide housing features an IP65/66/67 rating, which allows it to be mounted directly to machine frames in dusty, wet, or demanding physical environments.

What is the conversion speed and resolution of the BECKHOFF EPI4374-0002?

The BECKHOFF EPI4374-0002 features a high-accuracy 16-bit resolution (including sign). The typical conversion times are approximately 100 microseconds for the analog inputs and 40 microseconds for the analog outputs.

Is there electrical isolation on the BECKHOFF EPI4374-0002?

Yes, the BECKHOFF EPI4374-0002 features electrical isolation between the L+ sensor/logic power supply and the P24 actuator power supply lines.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...