BECKHOFF

BECKHOFF ERI1008-0001 IO-Link Box 8-Channel Digital Input

SKU ERI1008-0001

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: ERI1008-0001
  • Origin Germany
  • Product Type: IO-Link Modules
  • Payment: T/T, Western Union
  • Weight: 0.265 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The BECKHOFF ERI1008-0001 is an industrial-grade IO-Link box designed for direct field-level acquisition of digital signals without a control cabinet. Operating as an IO-Link device, this module transmits eight digital input signals from the field to an IO-Link master. Its design allows for decentralized installation, minimizing wiring runs and simplifying field integration in modern automation topologies.

Equipped with durable, screw-type M8 connection points for inputs and a single, A-coded M12 plug for the IO-Link interface, the BECKHOFF ERI1008-0001 ensures reliable electrical connections under constant mechanical vibration. It complies with the IO-Link V1.1 specification (Class A) and operates at the high-speed COM 3 transmission rate to deliver quick, reliable input state updates to the controller.

The module features Type 3 digital inputs conforming to EN 61131-2, ensuring high compatibility with standard proximity sensors and switches. Integrated protection features include short-circuit proof sensor supply and configurable input filter times to optimize signal integrity in electrically noisy environments.

Features

  • Eight independent digital input channels with Type 3 signal characteristics.
  • High-speed IO-Link communication (Class A) supporting data transfer rates up to 230.4 kbaud (COM 3).
  • Durable M8 screw-type connection points for secure sensor wiring.
  • Configurable input filter times from 0 to 20 ms to prevent contact bounce and signal noise.
  • Integrated sensor supply rated up to 0.5 A from the L+ line with complete short-circuit protection.
  • Heavy-duty ingress protection (IP65, IP66, and IP67) for installation in harsh, washdown, or dusty environments.

Applications

  • Decentralized input aggregation on robotic arms, gantry systems, and conveyor lines.
  • Machine-mount sensor wiring where cabinet space is unavailable or limited.
  • High-speed assembly and packaging machinery demanding low-latency digital signal processing.
  • Standardized connection of standard industrial sensors to IO-Link fieldbus systems.

Technical Specifications

General Specifications

Manufacturer BECKHOFF
Exact Model ERI1008-0001
Product Type IO-Link Box
Weight approx. 265 g

IO-Link and Communication

Protocol IO-Link
Specification Version IO-Link V1.1, Class A
Data Transfer Rates 230.4 kbaud (COM 3)
Interface Connection 1 x M12 plug, A-coded
Current Consumption typ. 100 mA from L+

Digital Inputs

Number of Inputs 8
Input Connection Type M8, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 3.0 ms (default), adjustable 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)
Sensor Supply max. 0.5 A (from L+), short-circuit proof in total

Environmental and Standards

Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Port Function
M12 Connector (A-coded) IO-Link upstream connection to master (Class A) and power supply
M8 Ports (Channels 1–8) Physical connections for the 8 digital input signals and sensor power

Installation Guidelines

  1. Verify Equipment: Ensure that the model number matches ERI1008-0001 and inspect the housing and connectors for physical integrity before mounting.
  2. Power De-energization: Isolate all electrical supply lines, including the IO-Link master feed, prior to performing installation or wiring procedures.
  3. Mechanical Mounting: Fasten the IO-Link box to a stable mounting surface using appropriate screws. The installation position is variable, but must prevent strain on connected cables.
  4. IO-Link Connection: Connect the A-coded M12 cable from the IO-Link master to the designated M12 port on the module. Hand-tighten the coupling ring to secure the ingress protection seal.
  5. Sensor Wiring: Connect the digital sensors to the M8 screw-type input ports. Ensure connectors are securely threaded to maintain the IP67 protection rating.
  6. System Commissioning: Apply supply voltage to the system. Configure the IO-Link master to recognize the device, setting the appropriate input filter times within the 0 to 20 ms range as dictated by your application.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary communication interface and transfer rate of the BECKHOFF ERI1008-0001?
The BECKHOFF ERI1008-0001 uses an IO-Link V1.1 (Class A) interface and communicates at a high-speed data transfer rate of 230.4 kbaud (COM 3) via a single A-coded M12 plug.
What connector types are used for the sensor inputs on the BECKHOFF ERI1008-0001?
The BECKHOFF ERI1008-0001 is equipped with 8 digital input channels accessible via screw-type M8 connectors.
Can the BECKHOFF ERI1008-0001 be mounted directly on a machine without an electrical cabinet?
Yes, the BECKHOFF ERI1008-0001 features an IP65, IP66, and IP67 protection rating, making it suitable for decentralized installation directly on machinery without requiring a control cabinet.
Does the BECKHOFF ERI1008-0001 provide power to the connected sensors?
Yes, the BECKHOFF ERI1008-0001 provides a short-circuit-proof sensor supply with a maximum combined current limit of 0.5 A drawn from the L+ line.
Are the input filters configurable on the BECKHOFF ERI1008-0001?
Yes, the BECKHOFF ERI1008-0001 features adjustable input filter times from 0 to 20 ms, with a default factory setting of 3.0 ms to help eliminate contact bounce and electromagnetic noise.
Reviews

ERI1008-0001

Stock & lead time on request

Call
1 su 1

BECKHOFF ERI1008-0001 IO-Link Box 8-Channel Digital Input

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ERI1008-0001

  • Country of origin:Germany

  • Product Type: IO-Link Modules

  • Payment: T/T, Western Union

  • Weight: 265g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF ERI1008-0001 is an industrial-grade IO-Link box designed for direct field-level acquisition of digital signals without a control cabinet. Operating as an IO-Link device, this module transmits eight digital input signals from the field to an IO-Link master. Its design allows for decentralized installation, minimizing wiring runs and simplifying field integration in modern automation topologies.

Equipped with durable, screw-type M8 connection points for inputs and a single, A-coded M12 plug for the IO-Link interface, the BECKHOFF ERI1008-0001 ensures reliable electrical connections under constant mechanical vibration. It complies with the IO-Link V1.1 specification (Class A) and operates at the high-speed COM 3 transmission rate to deliver quick, reliable input state updates to the controller.

The module features Type 3 digital inputs conforming to EN 61131-2, ensuring high compatibility with standard proximity sensors and switches. Integrated protection features include short-circuit proof sensor supply and configurable input filter times to optimize signal integrity in electrically noisy environments.

Features

  • Eight independent digital input channels with Type 3 signal characteristics.
  • High-speed IO-Link communication (Class A) supporting data transfer rates up to 230.4 kbaud (COM 3).
  • Durable M8 screw-type connection points for secure sensor wiring.
  • Configurable input filter times from 0 to 20 ms to prevent contact bounce and signal noise.
  • Integrated sensor supply rated up to 0.5 A from the L+ line with complete short-circuit protection.
  • Heavy-duty ingress protection (IP65, IP66, and IP67) for installation in harsh, washdown, or dusty environments.

Applications

  • Decentralized input aggregation on robotic arms, gantry systems, and conveyor lines.
  • Machine-mount sensor wiring where cabinet space is unavailable or limited.
  • High-speed assembly and packaging machinery demanding low-latency digital signal processing.
  • Standardized connection of standard industrial sensors to IO-Link fieldbus systems.

Technical Specifications

General Specifications

Manufacturer BECKHOFF
Exact Model ERI1008-0001
Product Type IO-Link Box
Weight approx. 265 g

IO-Link and Communication

Protocol IO-Link
Specification Version IO-Link V1.1, Class A
Data Transfer Rates 230.4 kbaud (COM 3)
Interface Connection 1 x M12 plug, A-coded
Current Consumption typ. 100 mA from L+

Digital Inputs

Number of Inputs 8
Input Connection Type M8, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 3.0 ms (default), adjustable 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)
Sensor Supply max. 0.5 A (from L+), short-circuit proof in total

Environmental and Standards

Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Port Function
M12 Connector (A-coded) IO-Link upstream connection to master (Class A) and power supply
M8 Ports (Channels 1–8) Physical connections for the 8 digital input signals and sensor power

Installation Guidelines

  1. Verify Equipment: Ensure that the model number matches ERI1008-0001 and inspect the housing and connectors for physical integrity before mounting.
  2. Power De-energization: Isolate all electrical supply lines, including the IO-Link master feed, prior to performing installation or wiring procedures.
  3. Mechanical Mounting: Fasten the IO-Link box to a stable mounting surface using appropriate screws. The installation position is variable, but must prevent strain on connected cables.
  4. IO-Link Connection: Connect the A-coded M12 cable from the IO-Link master to the designated M12 port on the module. Hand-tighten the coupling ring to secure the ingress protection seal.
  5. Sensor Wiring: Connect the digital sensors to the M8 screw-type input ports. Ensure connectors are securely threaded to maintain the IP67 protection rating.
  6. System Commissioning: Apply supply voltage to the system. Configure the IO-Link master to recognize the device, setting the appropriate input filter times within the 0 to 20 ms range as dictated by your application.
Loading product navigation…

What is the primary communication interface and transfer rate of the BECKHOFF ERI1008-0001?

The BECKHOFF ERI1008-0001 uses an IO-Link V1.1 (Class A) interface and communicates at a high-speed data transfer rate of 230.4 kbaud (COM 3) via a single A-coded M12 plug.

What connector types are used for the sensor inputs on the BECKHOFF ERI1008-0001?

The BECKHOFF ERI1008-0001 is equipped with 8 digital input channels accessible via screw-type M8 connectors.

Can the BECKHOFF ERI1008-0001 be mounted directly on a machine without an electrical cabinet?

Yes, the BECKHOFF ERI1008-0001 features an IP65, IP66, and IP67 protection rating, making it suitable for decentralized installation directly on machinery without requiring a control cabinet.

Does the BECKHOFF ERI1008-0001 provide power to the connected sensors?

Yes, the BECKHOFF ERI1008-0001 provides a short-circuit-proof sensor supply with a maximum combined current limit of 0.5 A drawn from the L+ line.

Are the input filters configurable on the BECKHOFF ERI1008-0001?

Yes, the BECKHOFF ERI1008-0001 features adjustable input filter times from 0 to 20 ms, with a default factory setting of 3.0 ms to help eliminate contact bounce and electromagnetic noise.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.