BECKHOFF

BECKHOFF ERI2339-0022 IO-Link Box

SKU ERI2339-0022

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: ERI2339-0022
  • Origin Germany
  • Product Type: IO-Link Boxes
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 60 mm x 126 mm x 26.5 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The BECKHOFF ERI2339-0022 is an IO-Link box designed for decentralized industrial automation tasks in harsh field environments. Functioning as an IO-Link device supporting specification version V1.1 Class B, this module provides flexible signal extension directly on machine frames without requiring a control cabinet. It integrates digital input and output channels within a durable metal housing, connecting seamlessly to higher-level IO-Link masters via standard M12 industrial cabling.

Constructed for demanding factory floor conditions, the unit features high environmental protection ratings and a robust zinc die-cast housing. It handles mixed signal distributions, supplying sensor power directly from internal supply rails while maintaining short-circuit protection across channels. The ERI2339-0022 streamlines machine-level wiring architectures by consolidating multiple digital signals into a single IO-Link communication line.

Features

  • IO-Link V1.1 Class B communication interface via M12 A-coded plug
  • Supports 16 digital inputs or outputs configurable for diverse machine signals
  • Robust zinc die-cast housing designed for variable installation positions
  • Integrated sensor and actuator supply sourced from P24 with total short-circuit protection
  • High environmental protection class for machine-level direct mounting
  • Configurable input filter times for signal debouncing and adaptation

Applications

  • Decentralized machine control and signal acquisition without control cabinets
  • Automated assembly systems requiring distributed digital I/O expansion
  • Material handling and conveyor equipment with harsh environmental exposures
  • Packaging machinery utilizing IO-Link sensor and actuator integration

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Exact Model ERI2339-0022
Product Type IO-Link Box
Communication Protocol IO-Link
Specification Version IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM 3)
Interface 1 x M12 plug, A-coded
Number of Channels 16 digital inputs or outputs
Input/Output Connections M12, screw type
Input Filter 3.0 ms (default), adjustable 0 to 20 ms
Signal Voltage 0 -3 to +5 V (EN 61131-2, type 3)
Signal Voltage 1 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)
Sensor Supply from P24, max. 0.5 A, short-circuit proof in total
Load Type ohmic, inductive, lamp load
Rated Load Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel, individually short-circuit proof, sum 4 A
Short-Circuit Current max. 1.5 A
Current Consumption typ. 100 mA from L+
Auxiliary Power Current typ. 20 mA plus load
Electrical Isolation L+ / P24: yes
Housing Data 16 x M8, 8 x M12
Dimensions (W x H x D) 60 mm x 126 mm x 26.5 mm
Net Weight approx. 450 g
Material Zinc die-cast
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL

Installation Guidelines

    Ensure all power supplies and field voltage sources are switched off and locked out before beginning installation or wiring work. Inspect the zinc die-cast housing, M12 connectors, and seals for any transit damage or contamination. Mount the module securely onto a flat machine surface using the designated fixing holes (M3 or M4 screws) in a variable installation position suited to the application. Connect the IO-Link master communication cable to the M12 A-coded interface port. Attach field sensors and actuators to the M12 input/output connection points, ensuring correct pin assignment and torque limits. Verify that the L+ and P24 supply voltages meet the rated nominal thresholds before energizing the system. Power on the system and verify module communication status and channel LEDs during commissioning.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF ERI2339-0022?
The BECKHOFF ERI2339-0022 is a decentralized IO-Link box that provides 16 configurable digital input or output channels for machine-level automation without requiring a control cabinet.
What communication standard does the BECKHOFF ERI2339-0022 support?
The BECKHOFF ERI2339-0022 communicates via IO-Link V1.1 Class B specifications at a data transfer rate of 230.4 kbaud using a COM 3 transmission rate through an M12 A-coded plug.
What is the enclosure protection rating of the BECKHOFF ERI2339-0022?
The BECKHOFF ERI2339-0022 features an IP65, IP66, and IP67 protection rating housed within a durable zinc die-cast frame, making it suitable for harsh industrial environments.
How are sensors and loads powered on the BECKHOFF ERI2339-0022?
The BECKHOFF ERI2339-0022 supplies sensor power from P24 up to 0.5 A with total short-circuit protection, and supports individual output channel currents up to 0.5 A with a total sum of 4 A.
Reviews

ERI2339-0022

Stock & lead time on request

Call
1 su 1

BECKHOFF ERI2339-0022 IO-Link Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ERI2339-0022

  • Country of origin:Germany

  • Product Type: IO-Link Boxes

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 60 mm x 126 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF ERI2339-0022 is an IO-Link box designed for decentralized industrial automation tasks in harsh field environments. Functioning as an IO-Link device supporting specification version V1.1 Class B, this module provides flexible signal extension directly on machine frames without requiring a control cabinet. It integrates digital input and output channels within a durable metal housing, connecting seamlessly to higher-level IO-Link masters via standard M12 industrial cabling.

Constructed for demanding factory floor conditions, the unit features high environmental protection ratings and a robust zinc die-cast housing. It handles mixed signal distributions, supplying sensor power directly from internal supply rails while maintaining short-circuit protection across channels. The ERI2339-0022 streamlines machine-level wiring architectures by consolidating multiple digital signals into a single IO-Link communication line.

Features

  • IO-Link V1.1 Class B communication interface via M12 A-coded plug
  • Supports 16 digital inputs or outputs configurable for diverse machine signals
  • Robust zinc die-cast housing designed for variable installation positions
  • Integrated sensor and actuator supply sourced from P24 with total short-circuit protection
  • High environmental protection class for machine-level direct mounting
  • Configurable input filter times for signal debouncing and adaptation

Applications

  • Decentralized machine control and signal acquisition without control cabinets
  • Automated assembly systems requiring distributed digital I/O expansion
  • Material handling and conveyor equipment with harsh environmental exposures
  • Packaging machinery utilizing IO-Link sensor and actuator integration

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Exact Model ERI2339-0022
Product Type IO-Link Box
Communication Protocol IO-Link
Specification Version IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM 3)
Interface 1 x M12 plug, A-coded
Number of Channels 16 digital inputs or outputs
Input/Output Connections M12, screw type
Input Filter 3.0 ms (default), adjustable 0 to 20 ms
Signal Voltage 0 -3 to +5 V (EN 61131-2, type 3)
Signal Voltage 1 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)
Sensor Supply from P24, max. 0.5 A, short-circuit proof in total
Load Type ohmic, inductive, lamp load
Rated Load Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel, individually short-circuit proof, sum 4 A
Short-Circuit Current max. 1.5 A
Current Consumption typ. 100 mA from L+
Auxiliary Power Current typ. 20 mA plus load
Electrical Isolation L+ / P24: yes
Housing Data 16 x M8, 8 x M12
Dimensions (W x H x D) 60 mm x 126 mm x 26.5 mm
Net Weight approx. 450 g
Material Zinc die-cast
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL

Installation Guidelines

    Ensure all power supplies and field voltage sources are switched off and locked out before beginning installation or wiring work. Inspect the zinc die-cast housing, M12 connectors, and seals for any transit damage or contamination. Mount the module securely onto a flat machine surface using the designated fixing holes (M3 or M4 screws) in a variable installation position suited to the application. Connect the IO-Link master communication cable to the M12 A-coded interface port. Attach field sensors and actuators to the M12 input/output connection points, ensuring correct pin assignment and torque limits. Verify that the L+ and P24 supply voltages meet the rated nominal thresholds before energizing the system. Power on the system and verify module communication status and channel LEDs during commissioning.
Loading product navigation…
Key Features:

What is the primary function of the BECKHOFF ERI2339-0022?

The BECKHOFF ERI2339-0022 is a decentralized IO-Link box that provides 16 configurable digital input or output channels for machine-level automation without requiring a control cabinet.

What communication standard does the BECKHOFF ERI2339-0022 support?

The BECKHOFF ERI2339-0022 communicates via IO-Link V1.1 Class B specifications at a data transfer rate of 230.4 kbaud using a COM 3 transmission rate through an M12 A-coded plug.

What is the enclosure protection rating of the BECKHOFF ERI2339-0022?

The BECKHOFF ERI2339-0022 features an IP65, IP66, and IP67 protection rating housed within a durable zinc die-cast frame, making it suitable for harsh industrial environments.

How are sensors and loads powered on the BECKHOFF ERI2339-0022?

The BECKHOFF ERI2339-0022 supplies sensor power from P24 up to 0.5 A with total short-circuit protection, and supports individual output channel currents up to 0.5 A with a total sum of 4 A.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.