Designed for direct installation in demanding industrial environments without a control cabinet, the IP2301-B400 provides a robust interface between Interbus networks and decentralized field sensors or actuators. This fieldbus box features a balanced combination of four digital inputs and four digital outputs in a compact, IP67-rated housing. By routing physical signals directly at the machine level, the module significantly minimizes wiring overhead, simplifies diagnostics, and optimizes signal propagation times.

The integrated digital inputs feature a 3 ms filter time to prevent contact bounce issues, while the short-circuit-proof digital outputs deliver up to 0.5 A per channel. Standardized M8 connectors ensure secure, vibration-resistant sensor and actuator cabling, making this unit highly suitable for dynamic mechanical setups.

Features

  • Direct Interbus fieldbus connection for high-speed decentralized communication.
  • Four digital inputs (24 V DC) with an integrated 3 ms input filter.
  • Four short-circuit proof digital outputs rated at 0.5 A per channel.
  • Compact, space-saving design with robust M8 connection technology.
  • IP67 protection class allowing direct mounting on machines without protective enclosures.

Applications

  • Decentralized machine control and plant automation architectures.
  • Automotive manufacturing assembly lines utilizing Interbus fieldbus networks.
  • Material handling, packaging machinery, and conveyor line routing.
  • Industrial robotics and end-of-arm tooling control setups.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model IP2301-B400
Product Family Fieldbus Box
Protocol / Interface Interbus
Number of Inputs 4 digital inputs (24 V DC)
Input Filter Time 3 ms
Number of Outputs 4 digital outputs (24 V DC)
Max. Output Current 0.5 A per channel
Connection Method M8 screw connectors (I/O)
Nominal Supply Voltage 24 V DC
Protection Rating IP67
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Shipping Weight 2.0 kg (approximate package weight)

Connections and Interfaces

M8 Connector Pin Input Channel Function Output Channel Function
Pin 1 +24 V DC Sensor Supply Not Connected / Free
Pin 3 0 V (GND) 0 V (GND)
Pin 4 Input Signal Output Signal (0.5 A)

Installation Guidelines

  • Mount the module directly to a flat machine frame or structure using the integrated mounting holes.
  • Ensure reliable grounding of the module case to the machinery frame to maximize electromagnetic compatibility (EMC).
  • Tighten all M8 mating connectors to the recommended torque specifications to maintain the IP67 environmental seal.
  • Route fieldbus and low-voltage control lines separate from high-noise power cables or AC motor drives to prevent signal interference.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What fieldbus protocol does the Beckhoff IP2301-B400 support?
The IP2301-B400 is designed specifically for integration with the Interbus fieldbus system.
What is the maximum current rating for the digital outputs on the IP2301-B400?
Each of the 4 digital outputs can supply a maximum current of 0.5 A at 24 V DC.
Does the IP2301-B400 require a control cabinet for installation?
No, with its IP67 protection rating, it is designed for direct machine mounting without an additional protective enclosure.
What type of connector is used for I/O wiring?
The module utilizes space-saving M8 screw connectors for both sensor inputs and actuator outputs.
Reviews

IP2301-B400

Stock & lead time on request

Call
1 su 1

BECKHOFF IP2301-B400 Fieldbus Box Digital I/O Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2301-B400

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for direct installation in demanding industrial environments without a control cabinet, the IP2301-B400 provides a robust interface between Interbus networks and decentralized field sensors or actuators. This fieldbus box features a balanced combination of four digital inputs and four digital outputs in a compact, IP67-rated housing. By routing physical signals directly at the machine level, the module significantly minimizes wiring overhead, simplifies diagnostics, and optimizes signal propagation times.

The integrated digital inputs feature a 3 ms filter time to prevent contact bounce issues, while the short-circuit-proof digital outputs deliver up to 0.5 A per channel. Standardized M8 connectors ensure secure, vibration-resistant sensor and actuator cabling, making this unit highly suitable for dynamic mechanical setups.

Features

  • Direct Interbus fieldbus connection for high-speed decentralized communication.
  • Four digital inputs (24 V DC) with an integrated 3 ms input filter.
  • Four short-circuit proof digital outputs rated at 0.5 A per channel.
  • Compact, space-saving design with robust M8 connection technology.
  • IP67 protection class allowing direct mounting on machines without protective enclosures.

Applications

  • Decentralized machine control and plant automation architectures.
  • Automotive manufacturing assembly lines utilizing Interbus fieldbus networks.
  • Material handling, packaging machinery, and conveyor line routing.
  • Industrial robotics and end-of-arm tooling control setups.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model IP2301-B400
Product Family Fieldbus Box
Protocol / Interface Interbus
Number of Inputs 4 digital inputs (24 V DC)
Input Filter Time 3 ms
Number of Outputs 4 digital outputs (24 V DC)
Max. Output Current 0.5 A per channel
Connection Method M8 screw connectors (I/O)
Nominal Supply Voltage 24 V DC
Protection Rating IP67
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Shipping Weight 2.0 kg (approximate package weight)

Connections and Interfaces

M8 Connector Pin Input Channel Function Output Channel Function
Pin 1 +24 V DC Sensor Supply Not Connected / Free
Pin 3 0 V (GND) 0 V (GND)
Pin 4 Input Signal Output Signal (0.5 A)

Installation Guidelines

  • Mount the module directly to a flat machine frame or structure using the integrated mounting holes.
  • Ensure reliable grounding of the module case to the machinery frame to maximize electromagnetic compatibility (EMC).
  • Tighten all M8 mating connectors to the recommended torque specifications to maintain the IP67 environmental seal.
  • Route fieldbus and low-voltage control lines separate from high-noise power cables or AC motor drives to prevent signal interference.

What fieldbus protocol does the Beckhoff IP2301-B400 support?

The IP2301-B400 is designed specifically for integration with the Interbus fieldbus system.

What is the maximum current rating for the digital outputs on the IP2301-B400?

Each of the 4 digital outputs can supply a maximum current of 0.5 A at 24 V DC.

Does the IP2301-B400 require a control cabinet for installation?

No, with its IP67 protection rating, it is designed for direct machine mounting without an additional protective enclosure.

What type of connector is used for I/O wiring?

The module utilizes space-saving M8 screw connectors for both sensor inputs and actuator outputs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...