The BECKHOFF IP2332-B518 is a compact decentralized Fieldbus Box designed for industrial automation environments requiring distributed signal acquisition and control. Engineered for direct machine-level mounting without the need for control cabinets, this IP65, IP66, and IP67 protected module integrates into CANopen network architectures. It facilitates reliable data communication, process data exchange, and sensor or actuator connection across harsh industrial machinery and plant floors.

Equipped with an integrated CANopen interface, the unit supports extensive process data object (PDO) configurations and diagnostic functions. Power distribution, fieldbus connections, and peripheral signal integration are handled via robust industrial circular connectors, supporting decentralized system topologies where space efficiency and environmental resistance are critical.

Features

  • Integrated CANopen bus interface with automatic baud rate detection from 10 kbaud up to 1 Mbaud
  • Supports up to 16 send and 16 receive process data objects (PDOs)
  • Comprehensive CANopen features including life guarding, node guarding, emergency objects, variable mapping, and store/restore functionality
  • Robust IP65, IP66, and IP67 protection rating for harsh industrial environments without control cabinets
  • Flexible configuration options via the KS2000 configuration software or through service data objects (SDOs) from the controller
  • Integrated M12 tee-connector for streamlined bus wiring topology

Applications

  • Decentralized machine control and automation systems
  • Automotive assembly lines and material handling equipment
  • Packaging and sorting machinery requiring cabinet-free I/O distribution
  • Conveyor systems and distributed manufacturing cells

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2332-B518
Product Type Fieldbus Box
Extension modules -
Country of Origin Germany

Communication and Bus Interface

Parameter Specification
Bus Interface 1 x M12 plug, 5-pin; 1 x M12 socket, 5-pin (tee-connector integrated)
Data Transfer Rates Automatic detection of 10 kbaud up to 1 Mbaud
Data Transfer Medium Shielded copper cable, 2 x signal, 1 x CAN ground (recommended)
Number of PDOs (CANopen) 16 send and 16 receive process data objects
Additional CANopen Features Life, node guarding, emergency object, variable mapping, store/restore
I/O Communication Types Event driven, cyclic, synchron, polling
Configuration Possibility Through KS2000 or the controller (service data objects)

Electrical

Parameter Specification
Power Supply Control Voltage 24 V DC (-15 %/+20 %)
Power Supply Load Voltage According to I/O type
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Box Supply Current 45 mA + current consumption of sensors, max. 0.5 A
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: 500 V; Control voltage/inputs or outputs: according to I/O type

Environmental and Mechanical

Parameter Specification
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Approvals and Markings CE, UL

Connections / Interfaces

Interface Function
M12 Plug (5-pin) / M12 Socket (5-pin) CANopen bus interface (integrated tee-connector)
M8 Male Socket (4-pin) Control voltage power supply feed
M8 Female Socket (4-pin) Downstream control voltage power supply connection

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or servicing the BECKHOFF IP2332-B518 Fieldbus Box.
  2. Inspect the module and connectors for any physical damage or contamination.
  3. Mount the unit securely to a flat, stable machine surface in any variable orientation permitted by the application.
  4. Connect the 24 V DC control voltage supply to the M8 feed socket using appropriate shielded cabling.
  5. Connect the CANopen network cables to the M12 bus ports, ensuring proper shielding and termination according to CANopen specifications.
  6. Verify all cable connections, potential levels, and address/baud rate settings before restoring power.
  7. Power on the system and verify operational status via diagnostic LEDs and controller communication.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the BECKHOFF IP2332-B518 Fieldbus Box and how is it mounted?
The BECKHOFF IP2332-B518 is a compact decentralized Fieldbus Box engineered for direct machine-level mounting without the need for control cabinets. It provides robust IP65, IP66, and IP67 protection ratings, making it ideal for harsh industrial environments where space efficiency is critical. The unit facilitates reliable sensor and actuator integration directly on plant floors.
What communication protocol and data transfer rates does this module support?
The BECKHOFF IP2332-B518 utilizes an integrated CANopen bus interface with automatic baud rate detection ranging from 10 kbaud up to 1 Mbaud. It supports up to 16 send and 16 receive process data objects (PDOs) for efficient data exchange. Additionally, it offers comprehensive features such as life guarding, node guarding, and emergency objects.
What are the power supply requirements for the BECKHOFF IP2332-B518?
The BECKHOFF IP2332-B518 operates on a control voltage power supply of 24 V DC with a tolerance of -15% to +20%. Power is distributed via an M8 male socket feed and an M8 female socket for downstream connections. The box supply current is 45 mA plus sensor consumption, reaching a maximum of 0.5 A.
How can the BECKHOFF IP2332-B518 be configured?
The BECKHOFF IP2332-B518 offers flexible configuration options utilizing the KS2000 configuration software. Alternatively, parameters can be configured directly through the controller using service data objects (SDOs). This ensures seamless integration into existing CANopen network architectures and distributed manufacturing cells.
What environmental conditions can the BECKHOFF IP2332-B518 withstand?
The BECKHOFF IP2332-B518 is designed to operate in ambient temperatures ranging from 0 to +55 degrees Celsius, with storage temperatures between -25 and +85 degrees Celsius. It conforms to EN standards for vibration resistance, shock resistance, and electromagnetic compatibility (EMC). Its IP65, IP66, and IP67 ratings ensure complete protection against dust and water ingress in demanding industrial applications.
Reviews

IP2332-B518

Stock & lead time on request

Call
1 su 1

BECKHOFF IP2332-B518 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2332-B518

  • Country of origin:Germany

  • Product Type: Moduli per bus di campo

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF IP2332-B518 is a compact decentralized Fieldbus Box designed for industrial automation environments requiring distributed signal acquisition and control. Engineered for direct machine-level mounting without the need for control cabinets, this IP65, IP66, and IP67 protected module integrates into CANopen network architectures. It facilitates reliable data communication, process data exchange, and sensor or actuator connection across harsh industrial machinery and plant floors.

Equipped with an integrated CANopen interface, the unit supports extensive process data object (PDO) configurations and diagnostic functions. Power distribution, fieldbus connections, and peripheral signal integration are handled via robust industrial circular connectors, supporting decentralized system topologies where space efficiency and environmental resistance are critical.

Features

  • Integrated CANopen bus interface with automatic baud rate detection from 10 kbaud up to 1 Mbaud
  • Supports up to 16 send and 16 receive process data objects (PDOs)
  • Comprehensive CANopen features including life guarding, node guarding, emergency objects, variable mapping, and store/restore functionality
  • Robust IP65, IP66, and IP67 protection rating for harsh industrial environments without control cabinets
  • Flexible configuration options via the KS2000 configuration software or through service data objects (SDOs) from the controller
  • Integrated M12 tee-connector for streamlined bus wiring topology

Applications

  • Decentralized machine control and automation systems
  • Automotive assembly lines and material handling equipment
  • Packaging and sorting machinery requiring cabinet-free I/O distribution
  • Conveyor systems and distributed manufacturing cells

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2332-B518
Product Type Fieldbus Box
Extension modules -
Country of Origin Germany

Communication and Bus Interface

Parameter Specification
Bus Interface 1 x M12 plug, 5-pin; 1 x M12 socket, 5-pin (tee-connector integrated)
Data Transfer Rates Automatic detection of 10 kbaud up to 1 Mbaud
Data Transfer Medium Shielded copper cable, 2 x signal, 1 x CAN ground (recommended)
Number of PDOs (CANopen) 16 send and 16 receive process data objects
Additional CANopen Features Life, node guarding, emergency object, variable mapping, store/restore
I/O Communication Types Event driven, cyclic, synchron, polling
Configuration Possibility Through KS2000 or the controller (service data objects)

Electrical

Parameter Specification
Power Supply Control Voltage 24 V DC (-15 %/+20 %)
Power Supply Load Voltage According to I/O type
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Box Supply Current 45 mA + current consumption of sensors, max. 0.5 A
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: 500 V; Control voltage/inputs or outputs: according to I/O type

Environmental and Mechanical

Parameter Specification
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Approvals and Markings CE, UL

Connections / Interfaces

Interface Function
M12 Plug (5-pin) / M12 Socket (5-pin) CANopen bus interface (integrated tee-connector)
M8 Male Socket (4-pin) Control voltage power supply feed
M8 Female Socket (4-pin) Downstream control voltage power supply connection

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or servicing the BECKHOFF IP2332-B518 Fieldbus Box.
  2. Inspect the module and connectors for any physical damage or contamination.
  3. Mount the unit securely to a flat, stable machine surface in any variable orientation permitted by the application.
  4. Connect the 24 V DC control voltage supply to the M8 feed socket using appropriate shielded cabling.
  5. Connect the CANopen network cables to the M12 bus ports, ensuring proper shielding and termination according to CANopen specifications.
  6. Verify all cable connections, potential levels, and address/baud rate settings before restoring power.
  7. Power on the system and verify operational status via diagnostic LEDs and controller communication.
Loading product navigation…

What is the BECKHOFF IP2332-B518 Fieldbus Box and how is it mounted?

The BECKHOFF IP2332-B518 is a compact decentralized Fieldbus Box engineered for direct machine-level mounting without the need for control cabinets. It provides robust IP65, IP66, and IP67 protection ratings, making it ideal for harsh industrial environments where space efficiency is critical. The unit facilitates reliable sensor and actuator integration directly on plant floors.

What communication protocol and data transfer rates does this module support?

The BECKHOFF IP2332-B518 utilizes an integrated CANopen bus interface with automatic baud rate detection ranging from 10 kbaud up to 1 Mbaud. It supports up to 16 send and 16 receive process data objects (PDOs) for efficient data exchange. Additionally, it offers comprehensive features such as life guarding, node guarding, and emergency objects.

What are the power supply requirements for the BECKHOFF IP2332-B518?

The BECKHOFF IP2332-B518 operates on a control voltage power supply of 24 V DC with a tolerance of -15% to +20%. Power is distributed via an M8 male socket feed and an M8 female socket for downstream connections. The box supply current is 45 mA plus sensor consumption, reaching a maximum of 0.5 A.

How can the BECKHOFF IP2332-B518 be configured?

The BECKHOFF IP2332-B518 offers flexible configuration options utilizing the KS2000 configuration software. Alternatively, parameters can be configured directly through the controller using service data objects (SDOs). This ensures seamless integration into existing CANopen network architectures and distributed manufacturing cells.

What environmental conditions can the BECKHOFF IP2332-B518 withstand?

The BECKHOFF IP2332-B518 is designed to operate in ambient temperatures ranging from 0 to +55 degrees Celsius, with storage temperatures between -25 and +85 degrees Celsius. It conforms to EN standards for vibration resistance, shock resistance, and electromagnetic compatibility (EMC). Its IP65, IP66, and IP67 ratings ensure complete protection against dust and water ingress in demanding industrial applications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Filtrare i segnali PLC rumorosi senza nascondere i guasti reali

Il filtraggio dell’input può stabilizzare i dati del PLC, ma un’eccessiva attenuazione ritarda gli allarmi e maschera i cambiamenti del processo. Scopri come diagnosticare il rumore, scegliere filtri...

SCR o PWM? Scegliere un azionamento per motori CC a spazzole

I sistemi di azionamento SCR e PWM regolano i motori CC a spazzole in modi diversi. Questo confronto analizza la qualità della coppia, l’intervallo di velocità, l’inversione, la frenatura, il rumore...

Come gli inverter industriali generano CA da un bus CC

Gli inverter industriali sintetizzano corrente alternata controllabile da un bus in corrente continua tramite la commutazione e il filtraggio dei semiconduttori. Questa guida illustra i ponti H, la...

Controllo della forza del robot: dal rilevamento del contatto alla stabilità del processo

Il controllo della forza consente a un robot di adattarsi al contatto invece di seguire esclusivamente la posizione. Questa guida confronta gli approcci al rilevamento, le modalità di controllo, i...

Quando la logica a livello di sensore è utile e quando nasconde i rischi

I sensori configurabili possono eseguire decisioni su finestre, latch, ritardi e logica booleana prima che i dati raggiungano un PLC. Il vantaggio è una risposta locale più rapida; il rischio...

Collegamento di GX Simulator a Factory I/O tramite OPC

Una configurazione stabile di messa in servizio virtuale Mitsubishi richiede più della semplice corrispondenza degli indirizzi. Questa guida spiega il percorso dei dati GX Simulator–OPC–Factory I/O,...