BECKHOFF

BECKHOFF KL3062 Bus Terminal

SKU KL3062

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: KL3062
  • Origin Germany
  • Product Type: Analog Input Modules
  • Payment: T/T, Western Union
  • Weight: 0.06 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Processing analog input signals in the 0 to 10 V range, the BECKHOFF KL3062 Bus Terminal features two single-ended channels designed for direct connection to industrial sensors and transmitters. This compact input module converts analog physical values into digital signals with a 12-bit resolution, ensuring reliable signal transmission to the higher-level automation controller via the K-bus. Utilizing a common internal ground connection for both channels, the terminal minimizes wiring complexity in standard control cabinet installations.

The KL3062 provides comprehensive galvanic isolation up to 500 V between the input circuitry and the internal K-bus. Operating without the need for dedicated power contacts, the terminal derives its required operating power directly from the K-bus interface. The robust IP20 design and standard DIN rail mounting compatibility make it suitable for seamless integration in complex PLC and DCS architectures.

Features

  • Two independent analog input channels.
  • Single-ended measurement technology sharing a common reference ground.
  • Standard 0 to 10 V signal voltage range.
  • 12-bit analog-to-digital resolution.
  • Integrated galvanic electrical isolation up to 500 V (K-bus to signal voltage).
  • Fast conversion time of approximately 2 ms.
  • Low power consumption directly from the K-bus (typically 60 mA).
  • No address or hardware configuration required prior to commissioning.

Applications

  • Industrial process control and monitoring systems.
  • Pneumatic and hydraulic valve position feedback.
  • Integration with pressure transmitters, flow meters, and distance sensors.
  • Factory automation and machine building installations.
  • Hazardous area applications requiring compliant ATEX/IECEx intrinsically safe parameters.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model KL3062
Number of Inputs 2
Power Supply Via the K-bus
Signal Voltage Range 0 to 10 V
Technology Single-ended
Internal Resistance typ. > 200 kOhm
Conversion Time approx. 2 ms
Resolution 12 bit
Measurement Error < +/-0.3% (relative to full scale value)
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus typ. 60 mA
Bit Width in Process Image Input: 2 x 16 bit data (2 x 8 bit control/status optional)
Configuration No address or configuration setting
Weight approx. 60 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Ex Marking ATEX: II 3 G Ex ec IIC T4 Gc, IECEx: Ex ec IIC T4 Gc

Connections and Interfaces

Terminal Point Function Assignment
1 Analog Input 1 (+)
5 Analog Input 2 (+)
3 0 V (Reference ground for Input 1)
7 0 V (Reference ground for Input 2)
4 Shield connection
8 Shield connection

Installation Guidelines

  • Mounting: Snap the module directly onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism engages securely.
  • Wiring: Use appropriate wire sizes with terminal connectors. For solid or stranded wires, ensure the maximum cross-section conforms to the terminal blocks' limit.
  • Shielding: Connect the analog cable shields to terminal points 4 or 8 to prevent electrostatic and electromagnetic interference from disrupting signal integrity.
  • Grounding: Ensure the DIN rail is grounded to a low-impedance earth system in compliance with standard electrical installation codes.

Compliance and Certifications

  • CE
  • UL
  • ATEX (II 3 G Ex ec IIC T4 Gc)
  • IECEx (Ex ec IIC T4 Gc)
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What signal range does the Beckhoff KL3062 support?
The Beckhoff KL3062 processes standard analog voltage signals in the 0 to 10 V range.
Does the KL3062 require separate power contacts for operation?
No, the KL3062 is powered directly via the K-bus, drawing typically 60 mA of current. It does not utilize power contacts.
What is the resolution and conversion speed of this bus terminal?
The terminal features a 12-bit resolution with a conversion time of approximately 2 ms.
Are the input channels isolated from the rest of the system?
Yes, there is electrical isolation of 500 V between the signal voltage circuitry and the internal K-bus.
Is the KL3062 suitable for installation in hazardous areas?
Yes, the module is certified under ATEX (II 3 G Ex ec IIC T4 Gc) and IECEx for safe use in classified zone 2 hazardous locations.
Reviews

KL3062

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF KL3062 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL3062

  • Country of origin:Germany

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 60g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Processing analog input signals in the 0 to 10 V range, the BECKHOFF KL3062 Bus Terminal features two single-ended channels designed for direct connection to industrial sensors and transmitters. This compact input module converts analog physical values into digital signals with a 12-bit resolution, ensuring reliable signal transmission to the higher-level automation controller via the K-bus. Utilizing a common internal ground connection for both channels, the terminal minimizes wiring complexity in standard control cabinet installations.

The KL3062 provides comprehensive galvanic isolation up to 500 V between the input circuitry and the internal K-bus. Operating without the need for dedicated power contacts, the terminal derives its required operating power directly from the K-bus interface. The robust IP20 design and standard DIN rail mounting compatibility make it suitable for seamless integration in complex PLC and DCS architectures.

Features

  • Two independent analog input channels.
  • Single-ended measurement technology sharing a common reference ground.
  • Standard 0 to 10 V signal voltage range.
  • 12-bit analog-to-digital resolution.
  • Integrated galvanic electrical isolation up to 500 V (K-bus to signal voltage).
  • Fast conversion time of approximately 2 ms.
  • Low power consumption directly from the K-bus (typically 60 mA).
  • No address or hardware configuration required prior to commissioning.

Applications

  • Industrial process control and monitoring systems.
  • Pneumatic and hydraulic valve position feedback.
  • Integration with pressure transmitters, flow meters, and distance sensors.
  • Factory automation and machine building installations.
  • Hazardous area applications requiring compliant ATEX/IECEx intrinsically safe parameters.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model KL3062
Number of Inputs 2
Power Supply Via the K-bus
Signal Voltage Range 0 to 10 V
Technology Single-ended
Internal Resistance typ. > 200 kOhm
Conversion Time approx. 2 ms
Resolution 12 bit
Measurement Error < +/-0.3% (relative to full scale value)
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus typ. 60 mA
Bit Width in Process Image Input: 2 x 16 bit data (2 x 8 bit control/status optional)
Configuration No address or configuration setting
Weight approx. 60 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Ex Marking ATEX: II 3 G Ex ec IIC T4 Gc, IECEx: Ex ec IIC T4 Gc

Connections and Interfaces

Terminal Point Function Assignment
1 Analog Input 1 (+)
5 Analog Input 2 (+)
3 0 V (Reference ground for Input 1)
7 0 V (Reference ground for Input 2)
4 Shield connection
8 Shield connection

Installation Guidelines

  • Mounting: Snap the module directly onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism engages securely.
  • Wiring: Use appropriate wire sizes with terminal connectors. For solid or stranded wires, ensure the maximum cross-section conforms to the terminal blocks' limit.
  • Shielding: Connect the analog cable shields to terminal points 4 or 8 to prevent electrostatic and electromagnetic interference from disrupting signal integrity.
  • Grounding: Ensure the DIN rail is grounded to a low-impedance earth system in compliance with standard electrical installation codes.

Compliance and Certifications

  • CE
  • UL
  • ATEX (II 3 G Ex ec IIC T4 Gc)
  • IECEx (Ex ec IIC T4 Gc)

What signal range does the Beckhoff KL3062 support?

The Beckhoff KL3062 processes standard analog voltage signals in the 0 to 10 V range.

Does the KL3062 require separate power contacts for operation?

No, the KL3062 is powered directly via the K-bus, drawing typically 60 mA of current. It does not utilize power contacts.

What is the resolution and conversion speed of this bus terminal?

The terminal features a 12-bit resolution with a conversion time of approximately 2 ms.

Are the input channels isolated from the rest of the system?

Yes, there is electrical isolation of 500 V between the signal voltage circuitry and the internal K-bus.

Is the KL3062 suitable for installation in hazardous areas?

Yes, the module is certified under ATEX (II 3 G Ex ec IIC T4 Gc) and IECEx for safe use in classified zone 2 hazardous locations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...