Description

Designed for integration into industrial K-bus systems, the BECKHOFF KL4032 analog output terminal generates high-precision signals across a range of -10 to +10 V. This industrial-grade module features two single-ended analog output channels with a 12-bit resolution, ensuring accurate transmission of control values to actuators, valves, variable speed drives, and other process control components.

The KL4032 is designed with short-circuit proof outputs and provides electrical isolation between the internal K-bus and the signal field lines. Highly integrated and compact, this terminal is powered directly via the K-bus, eliminating the need for additional power contacts. It is fully compatible with standard Beckhoff KSxxxx pluggable wiring systems, simplifying maintenance and installation inside control cabinets.

Features

  • Two single-ended analog output channels for -10 to +10 V signals.
  • 12-bit digital-to-analog resolution for reliable process control.
  • Short-circuit proof signal outputs with a minimum load impedance of 5 kOhm.
  • Complete galvanic isolation up to 500 V between the internal K-bus and the signal electronics.
  • Direct power supply through the internal K-bus connection (75 mA typical current consumption).
  • No hardware address or complex manual configuration settings required.

Applications

  • Power generation and distribution facility automation.
  • Oil and gas refinery process control loops.
  • Water and wastewater plant automation systems.
  • Pneumatic and hydraulic valve actuator control.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model KL4032
Number of Outputs 2
Signal Voltage -10 to +10 V
Output Technology Single-ended
Resolution 12 bit
Conversion Time approx. 1.5 ms
Output Error < +/-0.1 % (relative to final value)
Load Protection > 5 kOhm (short-circuit proof)
Power Supply Via K-bus
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-Bus typ. 75 mA
Current Consumption Power Contacts None (no power contacts)
Bit Width in Process Image Output: 2 x 16 bit data (2 x 8 bit control/status optional)
Configuration No address or configuration setting
Weight approx. 85 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Pluggable Wiring Option Compatible with KSxxxx terminals

Installation Guidelines

The BECKHOFF KL4032 is designed for variable mounting on standard 35 mm DIN rails (EN 60715). Ensure correct interlocking of K-bus terminal side-guides to guarantee continuous communication. For optimal noise rejection in high-interference environments, use shielded cables and ground the shield at the entry point of the control panel. Do not block the ventilation slots to maintain the operating temperature below 60 degC.

Compliance and Certifications

  • CE
  • UL
  • DNV GL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • IECEx: Ex ec IIC T4 Gc
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the signal voltage range of the BECKHOFF KL4032?
The KL4032 features a signal voltage range of -10 to +10 V across two single-ended analog output channels.
Does the KL4032 terminal require an external power supply?
No, the KL4032 terminal is powered directly through the internal K-bus. It does not require power contacts.
Is the KL4032 analog output protected against short circuits?
Yes, the KL4032 analog outputs are short-circuit proof with a minimum load resistance requirement of 5 kOhm.
What are the ATEX and IECEx classifications for the KL4032?
The module is ATEX certified for II 3 G Ex nA IIC T4 Gc, and IECEx certified for Ex ec IIC T4 Gc, making it suitable for certain hazardous area applications.
Reviews

KL4032

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF KL4032 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL4032

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 85g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for integration into industrial K-bus systems, the BECKHOFF KL4032 analog output terminal generates high-precision signals across a range of -10 to +10 V. This industrial-grade module features two single-ended analog output channels with a 12-bit resolution, ensuring accurate transmission of control values to actuators, valves, variable speed drives, and other process control components.

The KL4032 is designed with short-circuit proof outputs and provides electrical isolation between the internal K-bus and the signal field lines. Highly integrated and compact, this terminal is powered directly via the K-bus, eliminating the need for additional power contacts. It is fully compatible with standard Beckhoff KSxxxx pluggable wiring systems, simplifying maintenance and installation inside control cabinets.

Features

  • Two single-ended analog output channels for -10 to +10 V signals.
  • 12-bit digital-to-analog resolution for reliable process control.
  • Short-circuit proof signal outputs with a minimum load impedance of 5 kOhm.
  • Complete galvanic isolation up to 500 V between the internal K-bus and the signal electronics.
  • Direct power supply through the internal K-bus connection (75 mA typical current consumption).
  • No hardware address or complex manual configuration settings required.

Applications

  • Power generation and distribution facility automation.
  • Oil and gas refinery process control loops.
  • Water and wastewater plant automation systems.
  • Pneumatic and hydraulic valve actuator control.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model KL4032
Number of Outputs 2
Signal Voltage -10 to +10 V
Output Technology Single-ended
Resolution 12 bit
Conversion Time approx. 1.5 ms
Output Error < +/-0.1 % (relative to final value)
Load Protection > 5 kOhm (short-circuit proof)
Power Supply Via K-bus
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-Bus typ. 75 mA
Current Consumption Power Contacts None (no power contacts)
Bit Width in Process Image Output: 2 x 16 bit data (2 x 8 bit control/status optional)
Configuration No address or configuration setting
Weight approx. 85 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Pluggable Wiring Option Compatible with KSxxxx terminals

Installation Guidelines

The BECKHOFF KL4032 is designed for variable mounting on standard 35 mm DIN rails (EN 60715). Ensure correct interlocking of K-bus terminal side-guides to guarantee continuous communication. For optimal noise rejection in high-interference environments, use shielded cables and ground the shield at the entry point of the control panel. Do not block the ventilation slots to maintain the operating temperature below 60 degC.

Compliance and Certifications

  • CE
  • UL
  • DNV GL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • IECEx: Ex ec IIC T4 Gc

What is the signal voltage range of the BECKHOFF KL4032?

The KL4032 features a signal voltage range of -10 to +10 V across two single-ended analog output channels.

Does the KL4032 terminal require an external power supply?

No, the KL4032 terminal is powered directly through the internal K-bus. It does not require power contacts.

Is the KL4032 analog output protected against short circuits?

Yes, the KL4032 analog outputs are short-circuit proof with a minimum load resistance requirement of 5 kOhm.

What are the ATEX and IECEx classifications for the KL4032?

The module is ATEX certified for II 3 G Ex nA IIC T4 Gc, and IECEx certified for Ex ec IIC T4 Gc, making it suitable for certain hazardous area applications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...