Designed specifically for the extreme conditions of wet cooling towers, the Bently Nevada 190501-01-00-04 is a specialized Velomitor CT Velocity Transducer engineered for low-speed machinery monitoring. This high-reliability vibration sensor measures casing vibration velocity, making it ideal for tracking structural and mechanical faults in cooling tower fans, gearboxes, and low-speed shaft assemblies.

The core construction of the 190501-01-00-04 features a hermetically sealed 316L stainless steel housing that completely isolates the internal sensing elements from 100% condensing humidity, corrosive water chemistry, and ambient contaminants. Unlike traditional velocity transducers that utilize moving coils prone to mechanical wear, this solid-state transducer employs internal integration electronics to convert acceleration measurements into a highly accurate velocity output signal, ensuring long-term measurement stability and minimal calibration drift.

Integrated easily into industrial monitoring systems, this sensor connects directly to the Bently Nevada 3500 Machinery Protection System via the 3500/42M Reciprocating Machinery Monitor or 3500/42 micro-locked channels, as well as distributed control systems (DCS) and PLC analog inputs that support dynamic vibration integration.

Features

  • Solid-state design with zero moving parts, eliminating mechanical wear and drift.
  • Hermetically sealed 316L stainless steel casing engineered to withstand continuous water exposure and wet cooling tower microclimates.
  • Internal integration circuit that converts acceleration to velocity for clean, noise-immune output signal transmission.
  • Optimized low-frequency response down to 1.5 Hz to capture structural resonance and low-speed rotational faults.
  • Standard top-exit 2-pin MIL-C-5015 connector configuration.
  • Broad dynamic range designed to capture both subtle imbalance forces and severe mechanical impacts.

Applications

  • Cooling tower fan drive assemblies
  • Air-cooled heat exchangers (fin fans)
  • Low-speed industrial gearboxes and agitators
  • Water and wastewater treatment circulating pumps
  • Exhaust ventilation systems

Technical Specifications

Manufacturer Bently Nevada
Part Number 190501-01-00-04
Series Velomitor CT (Cooling Tower) Velocity Transducer
Sensitivity 3.94 mV/mm/s (100 mV/in/s) plus/minus 5% at 100 Hz
Frequency Response 1.5 Hz to 1.0 kHz (90 to 60,000 cpm) plus/minus 3.0 dB; 3.0 Hz to 900 Hz plus/minus 1.0 dB
Velocity Range 127 mm/s (5.0 in/s) peak
Transducer Orientation Omnidirectional (any angle of mounting)
Operating Temperature -40 degC to +121 degC (-40 degF to +250 degF)
Excitation Voltage 15 to 30 VDC (2 to 10 mA constant current source)
Output Impedance Less than 100 Ohms
Case Material 316L stainless steel
Enclosure Rating Hermetically sealed, equivalent to IP66/IP68
Connector Type 2-pin MIL-C-5015 top connector
Mounting Thread 1/2-20 UNF (Option -01 configuration)

Connections and Interfaces

MIL-C-5015 Pin Signal Designation
Pin A Signal / Power (+)
Pin B Common / Return (-)
Shield Connected to transducer case internally (or isolated based on system grounding protocol)

Installation Guidelines

  • Mounting Torque: Tighten the transducer to the mounting surface using a maximum torque of 34 N-m (25 ft-lb) to ensure proper acoustic coupling without damaging the sensor threads.
  • Surface Preparation: Ensure the mating surface is flat, clean, and free of paint, scale, or debris. Use a light coating of silicone grease or coupling fluid before mounting.
  • Cabling and Routing: Always use shielded, twisted-pair cabling to minimize electromagnetic interference (EMI). Route cables through protective conduit or secure them with heavy-duty cable ties in cooling tower plenums to prevent mechanical strain.
  • Grounding: Ensure the shield is grounded at the monitor end only to prevent ground loops that introduce electronic noise into the vibration signal.

Compliance and Certifications

  • ATEX (Zone 0/1/2 Hazardous Areas)
  • IECEx
  • CSA/US Class I, Division 1 & 2 Groups A, B, C, D
  • CE Compliant
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Qual è la differenza principale tra il Velomitor standard e il Velomitor CT?
Il Velomitor CT (Cooling Tower) è ottimizzato specificamente per il monitoraggio delle vibrazioni a bassa frequenza (fino a 1,5 Hz) e presenta una tenuta ermetica più robusta, in grado di resistere all'umidità condensante al 100% e all'ambiente corrosivo presenti all'interno delle torri di raffreddamento.
Il Velomitor CT 190501-01-00-04 richiede un trasmettitore esterno?
No, è un trasduttore autonomo che emette un segnale di tensione a bassa impedenza proporzionale alla velocità. Può essere cablato direttamente a monitor di vibrazioni (come il Bently Nevada 3500) o a schede di ingresso analogico PLC/DCS che accettano accelerometri/sensori di velocità a corrente costante a 2 fili.
Quale configurazione di montaggio è specificata dall'opzione -01 nel codice prodotto 190501-01-00-04?
L'opzione di montaggio -01 specifica un adattatore di montaggio filettato 1/2-20 UNF per un accoppiamento meccanico sicuro all'involucro del macchinario.
Qual è l'intervallo di temperatura operativa consigliato per questo sensore di velocità?
Il sensore funziona in modo affidabile in un intervallo di temperatura compreso tra -40 °C e +121 °C (da -40 °F a +250 °F).
Reviews

190501-01-00-04

Stock & lead time on request

Call
1 su 3

Bently Nevada 190501-01-00-04 Velomitor CT Trasduttore di velocità

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 190501-01-00-04

  • Country of origin:United States

  • Product Type: Trasduttori di velocità

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 960g

  • Dimensions: 30.5cm x 30cm x 4.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed specifically for the extreme conditions of wet cooling towers, the Bently Nevada 190501-01-00-04 is a specialized Velomitor CT Velocity Transducer engineered for low-speed machinery monitoring. This high-reliability vibration sensor measures casing vibration velocity, making it ideal for tracking structural and mechanical faults in cooling tower fans, gearboxes, and low-speed shaft assemblies.

The core construction of the 190501-01-00-04 features a hermetically sealed 316L stainless steel housing that completely isolates the internal sensing elements from 100% condensing humidity, corrosive water chemistry, and ambient contaminants. Unlike traditional velocity transducers that utilize moving coils prone to mechanical wear, this solid-state transducer employs internal integration electronics to convert acceleration measurements into a highly accurate velocity output signal, ensuring long-term measurement stability and minimal calibration drift.

Integrated easily into industrial monitoring systems, this sensor connects directly to the Bently Nevada 3500 Machinery Protection System via the 3500/42M Reciprocating Machinery Monitor or 3500/42 micro-locked channels, as well as distributed control systems (DCS) and PLC analog inputs that support dynamic vibration integration.

Features

  • Solid-state design with zero moving parts, eliminating mechanical wear and drift.
  • Hermetically sealed 316L stainless steel casing engineered to withstand continuous water exposure and wet cooling tower microclimates.
  • Internal integration circuit that converts acceleration to velocity for clean, noise-immune output signal transmission.
  • Optimized low-frequency response down to 1.5 Hz to capture structural resonance and low-speed rotational faults.
  • Standard top-exit 2-pin MIL-C-5015 connector configuration.
  • Broad dynamic range designed to capture both subtle imbalance forces and severe mechanical impacts.

Applications

  • Cooling tower fan drive assemblies
  • Air-cooled heat exchangers (fin fans)
  • Low-speed industrial gearboxes and agitators
  • Water and wastewater treatment circulating pumps
  • Exhaust ventilation systems

Technical Specifications

Manufacturer Bently Nevada
Part Number 190501-01-00-04
Series Velomitor CT (Cooling Tower) Velocity Transducer
Sensitivity 3.94 mV/mm/s (100 mV/in/s) plus/minus 5% at 100 Hz
Frequency Response 1.5 Hz to 1.0 kHz (90 to 60,000 cpm) plus/minus 3.0 dB; 3.0 Hz to 900 Hz plus/minus 1.0 dB
Velocity Range 127 mm/s (5.0 in/s) peak
Transducer Orientation Omnidirectional (any angle of mounting)
Operating Temperature -40 degC to +121 degC (-40 degF to +250 degF)
Excitation Voltage 15 to 30 VDC (2 to 10 mA constant current source)
Output Impedance Less than 100 Ohms
Case Material 316L stainless steel
Enclosure Rating Hermetically sealed, equivalent to IP66/IP68
Connector Type 2-pin MIL-C-5015 top connector
Mounting Thread 1/2-20 UNF (Option -01 configuration)

Connections and Interfaces

MIL-C-5015 Pin Signal Designation
Pin A Signal / Power (+)
Pin B Common / Return (-)
Shield Connected to transducer case internally (or isolated based on system grounding protocol)

Installation Guidelines

  • Mounting Torque: Tighten the transducer to the mounting surface using a maximum torque of 34 N-m (25 ft-lb) to ensure proper acoustic coupling without damaging the sensor threads.
  • Surface Preparation: Ensure the mating surface is flat, clean, and free of paint, scale, or debris. Use a light coating of silicone grease or coupling fluid before mounting.
  • Cabling and Routing: Always use shielded, twisted-pair cabling to minimize electromagnetic interference (EMI). Route cables through protective conduit or secure them with heavy-duty cable ties in cooling tower plenums to prevent mechanical strain.
  • Grounding: Ensure the shield is grounded at the monitor end only to prevent ground loops that introduce electronic noise into the vibration signal.

Compliance and Certifications

  • ATEX (Zone 0/1/2 Hazardous Areas)
  • IECEx
  • CSA/US Class I, Division 1 & 2 Groups A, B, C, D
  • CE Compliant

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 190501-01-00-04 Velomitor CT Trasduttore di velocità

Qual è la differenza principale tra il Velomitor standard e il Velomitor CT?

Il Velomitor CT (Cooling Tower) è ottimizzato specificamente per il monitoraggio delle vibrazioni a bassa frequenza (fino a 1,5 Hz) e presenta una tenuta ermetica più robusta, in grado di resistere all'umidità condensante al 100% e all'ambiente corrosivo presenti all'interno delle torri di raffreddamento.

Il Velomitor CT 190501-01-00-04 richiede un trasmettitore esterno?

No, è un trasduttore autonomo che emette un segnale di tensione a bassa impedenza proporzionale alla velocità. Può essere cablato direttamente a monitor di vibrazioni (come il Bently Nevada 3500) o a schede di ingresso analogico PLC/DCS che accettano accelerometri/sensori di velocità a corrente costante a 2 fili.

Quale configurazione di montaggio è specificata dall'opzione -01 nel codice prodotto 190501-01-00-04?

L'opzione di montaggio -01 specifica un adattatore di montaggio filettato 1/2-20 UNF per un accoppiamento meccanico sicuro all'involucro del macchinario.

Qual è l'intervallo di temperatura operativa consigliato per questo sensore di velocità?

Il sensore funziona in modo affidabile in un intervallo di temperatura compreso tra -40 °C e +121 °C (da -40 °F a +250 °F).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.