Bently Nevada

Bently Nevada 330730-080-12-05 3300 XL 11 mm Extension Cable

SKU 330730-080-12-05

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 330730-080-12-05
  • Origin United States
  • Product Type: 3300 XL 11 mm Extension Cable
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.18 kg
  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330730-080-12-05 3300 XL 11 mm Extension Cable

Quantità

Product Description

Description

330730-080-12-05 specifies this 8.0-meter 3300 XL 11 mm extension cable configuration, featuring an integrated FluidLoc cable with a coaxial connector protector (Option 12) and multiple hazardous area agency approvals (Option 05).

This specific configuration leverages a FluidLoc cable to block process fluids and oils from migrating through the internal structure of the cable. The inclusion of a connector protector shields the miniature coaxial ClickLoc connection from moisture, dust, and corrosive environments, making it distinct from standard unarmored and unprotected cables like option 00 or armored equivalents like option 01. The 8.0-meter length is typically combined with a 1.0-meter 11 mm probe to establish a standard 9.0-meter total system length, which connects directly to a 9.0-meter 3300 XL Proximitor sensor.

Features

  • 8.0-Meter Cable Length (Option 080): Extends probe reach to span 8.0 meters (26.2 feet), providing the critical component to build a 9.0-meter transducer system length when paired with a 1.0-meter 11 mm probe.
  • FluidLoc Cable Technology (Option 12): Features an oil-blocking core that prevents process lubricants, synthetic oils, and other machinery fluids from leaking out of the machine housing through the cable's interior.
  • Integrated Connector Protector (Option 12): Includes a pre-installed fluorosilicone connector protector on the female ClickLoc connector, shielding the critical connection against humidity, moisture, and contamination.
  • Multiple Agency Approvals (Option 05): Certified for hazardous areas with international approvals including ATEX, IECEx, and North American CNRTLUs standards.
  • Gold-Plated ClickLoc Connectors: Uses premium gold-plated brass connectors that securely lock in place, ensuring low signal loss and preventing accidental loosening under high vibration.
  • High Temperature Resistance: Formulated with durable FEP insulation to withstand continuous exposure in harsh industrial environments from -52 degC to +177 degC.

Applications

  • Shaft radial vibration and axial position measurements on steam turbines, gas turbines, and large industrial compressors.
  • High-moisture and fluid-exposed monitoring locations requiring oil leakage prevention via the cable interior.
  • Heavy-duty machinery protection monitoring in chemical processing, power plants, and oil and gas industries.
  • Extension of 11 mm non-contact proximity probe transducer setups to complete 9.0-meter system loops.

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330730-080-12-05 3300 XL 11 mm extension cable
A - Cable Length Option 080 8.0 meters (26.2 feet)
B - Connector and Cable Option 12 FluidLoc cable with connector protector
C - Agency Approval Option 05 Multiple Approvals

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Model / Part Number 330730-080-12-05
Cable Type 75 ohm triaxial, FEP insulated, FluidLoc oil-blocking design
Cable Length 8.0 meters (26.2 feet)
Extension Cable DC Resistance (Rjacket) 2.0 +/- 0.5 ohms (coaxial conductor to coaxial conductor)
Extension Cable DC Resistance (Rcore) 0.6 +/- 0.2 ohms (center conductor to center conductor)
Extension Cable Capacitance 69.9 pF/m (21.3 pF/ft) typical
Connector Material Gold-plated brass
Connector Type Miniature coaxial ClickLoc connectors (female and male)
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Tensile Strength 270 N (60 pounds) maximum rated at probe lead to extension cable connectors
Minimum Bend Radius 25.4 mm (1.0 in)
Connector-to-Connector Torque Recommended finger tight; Maximum 0.565 N-m (5 in-lb)

Installation Guidelines

  • System Length Matching: Ensure that the probe length and the extension cable length, when added together, equal the Proximitor sensor total length (e.g., 1.0-meter probe + 8.0-meter extension cable = 9.0-meter Proximitor sensor system).
  • Connector Torque: ClickLoc connectors should be joined finger-tight. The maximum rated torque is 0.565 N-m (5 in-lb). Do not use pliers or excessive force.
  • Minimum Bend Radius: Maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing to prevent internal damage to the coaxial structure.
  • Connector Protection: The female connector is fitted with a fluorosilicone protector. Ensure it is fully engaged over the male probe connector during installation to prevent ingress of oil and moisture.

Compliance and Certifications

  • Hazardous Area Classifications: Multi-agency approvals (Option 05) including ATEX, IECEx, and CNRTLUs for Class I Zone 0, Zone 2, Div 1, and Div 2 environments.
  • Functional Safety: Certified for use in SIL 2 applications (HFT = 0) and SIL 3 applications (HFT = 1).
  • Environmental Standards: RoHS compliant.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the purpose of the FluidLoc feature on the 330730-080-12-05 extension cable?
The FluidLoc cable (Option 12) is designed with an internal sealing material that prevents turbine oil, process liquids, and other fluids from leaking out of the machine housing through the cable's interior.
What system length does this 8.0-meter extension cable support?
This 8.0-meter extension cable is designed to pair with a 1.0-meter 3300 XL 11 mm proximity probe to form a complete 9.0-meter transducer system, connecting directly to a 9.0-meter Proximitor sensor.
What does the connector protector provide on this extension cable configuration?
The pre-installed fluorosilicone connector protector provides additional environmental sealing for the coaxial ClickLoc connection, protecting it from humidity, moisture, and corrosive substances in harsh environments.
What is the maximum torque and minimum bend radius for routing this cable?
The minimum bend radius is 25.4 mm (1.0 inch) to preserve coaxial signal integrity, and the miniature coaxial ClickLoc connectors should be tightened finger-tight, with a maximum rated torque of 0.565 N-m (5 in-lb).
Reviews

330730-080-12-05

Stock & lead time on request

Call
1 su 3

Bently Nevada 330730-080-12-05 3300 XL 11 mm Extension Cable

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 330730-080-12-05

  • Country of origin:United States

  • Product Type: 3300 XL 11 mm Extension Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

330730-080-12-05 specifies this 8.0-meter 3300 XL 11 mm extension cable configuration, featuring an integrated FluidLoc cable with a coaxial connector protector (Option 12) and multiple hazardous area agency approvals (Option 05).

This specific configuration leverages a FluidLoc cable to block process fluids and oils from migrating through the internal structure of the cable. The inclusion of a connector protector shields the miniature coaxial ClickLoc connection from moisture, dust, and corrosive environments, making it distinct from standard unarmored and unprotected cables like option 00 or armored equivalents like option 01. The 8.0-meter length is typically combined with a 1.0-meter 11 mm probe to establish a standard 9.0-meter total system length, which connects directly to a 9.0-meter 3300 XL Proximitor sensor.

Features

  • 8.0-Meter Cable Length (Option 080): Extends probe reach to span 8.0 meters (26.2 feet), providing the critical component to build a 9.0-meter transducer system length when paired with a 1.0-meter 11 mm probe.
  • FluidLoc Cable Technology (Option 12): Features an oil-blocking core that prevents process lubricants, synthetic oils, and other machinery fluids from leaking out of the machine housing through the cable's interior.
  • Integrated Connector Protector (Option 12): Includes a pre-installed fluorosilicone connector protector on the female ClickLoc connector, shielding the critical connection against humidity, moisture, and contamination.
  • Multiple Agency Approvals (Option 05): Certified for hazardous areas with international approvals including ATEX, IECEx, and North American CNRTLUs standards.
  • Gold-Plated ClickLoc Connectors: Uses premium gold-plated brass connectors that securely lock in place, ensuring low signal loss and preventing accidental loosening under high vibration.
  • High Temperature Resistance: Formulated with durable FEP insulation to withstand continuous exposure in harsh industrial environments from -52 degC to +177 degC.

Applications

  • Shaft radial vibration and axial position measurements on steam turbines, gas turbines, and large industrial compressors.
  • High-moisture and fluid-exposed monitoring locations requiring oil leakage prevention via the cable interior.
  • Heavy-duty machinery protection monitoring in chemical processing, power plants, and oil and gas industries.
  • Extension of 11 mm non-contact proximity probe transducer setups to complete 9.0-meter system loops.

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330730-080-12-05 3300 XL 11 mm extension cable
A - Cable Length Option 080 8.0 meters (26.2 feet)
B - Connector and Cable Option 12 FluidLoc cable with connector protector
C - Agency Approval Option 05 Multiple Approvals

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Model / Part Number 330730-080-12-05
Cable Type 75 ohm triaxial, FEP insulated, FluidLoc oil-blocking design
Cable Length 8.0 meters (26.2 feet)
Extension Cable DC Resistance (Rjacket) 2.0 +/- 0.5 ohms (coaxial conductor to coaxial conductor)
Extension Cable DC Resistance (Rcore) 0.6 +/- 0.2 ohms (center conductor to center conductor)
Extension Cable Capacitance 69.9 pF/m (21.3 pF/ft) typical
Connector Material Gold-plated brass
Connector Type Miniature coaxial ClickLoc connectors (female and male)
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Tensile Strength 270 N (60 pounds) maximum rated at probe lead to extension cable connectors
Minimum Bend Radius 25.4 mm (1.0 in)
Connector-to-Connector Torque Recommended finger tight; Maximum 0.565 N-m (5 in-lb)

Installation Guidelines

  • System Length Matching: Ensure that the probe length and the extension cable length, when added together, equal the Proximitor sensor total length (e.g., 1.0-meter probe + 8.0-meter extension cable = 9.0-meter Proximitor sensor system).
  • Connector Torque: ClickLoc connectors should be joined finger-tight. The maximum rated torque is 0.565 N-m (5 in-lb). Do not use pliers or excessive force.
  • Minimum Bend Radius: Maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing to prevent internal damage to the coaxial structure.
  • Connector Protection: The female connector is fitted with a fluorosilicone protector. Ensure it is fully engaged over the male probe connector during installation to prevent ingress of oil and moisture.

Compliance and Certifications

  • Hazardous Area Classifications: Multi-agency approvals (Option 05) including ATEX, IECEx, and CNRTLUs for Class I Zone 0, Zone 2, Div 1, and Div 2 environments.
  • Functional Safety: Certified for use in SIL 2 applications (HFT = 0) and SIL 3 applications (HFT = 1).
  • Environmental Standards: RoHS compliant.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330730-080-12-05 3300 XL 11 mm Extension Cable

What is the purpose of the FluidLoc feature on the 330730-080-12-05 extension cable?

The FluidLoc cable (Option 12) is designed with an internal sealing material that prevents turbine oil, process liquids, and other fluids from leaking out of the machine housing through the cable's interior.

What system length does this 8.0-meter extension cable support?

This 8.0-meter extension cable is designed to pair with a 1.0-meter 3300 XL 11 mm proximity probe to form a complete 9.0-meter transducer system, connecting directly to a 9.0-meter Proximitor sensor.

What does the connector protector provide on this extension cable configuration?

The pre-installed fluorosilicone connector protector provides additional environmental sealing for the coaxial ClickLoc connection, protecting it from humidity, moisture, and corrosive substances in harsh environments.

What is the maximum torque and minimum bend radius for routing this cable?

The minimum bend radius is 25.4 mm (1.0 inch) to preserve coaxial signal integrity, and the miniature coaxial ClickLoc connectors should be tightened finger-tight, with a maximum rated torque of 0.565 N-m (5 in-lb).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...