Delta Electronics

DELTA VFD17AMS43ANSAA MS300 Series Variable Frequency Drive

SKU VFD17AMS43ANSAA

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics
  • Product No.: VFD17AMS43ANSAA
  • Origin United States
  • Product Type: MS300 Series Variable Frequency Drive
  • Payment: T/T, Western Union
  • Weight: 4.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Market-Leading Motor Control Overview

The VFD17AMS43ANSAA (VFD17AMS43ANSAA) is a high-performance standard micro drive engineered by Delta for demanding industrial automation applications. Operating as a core component within the globally trusted MS300 Series, this compact variable frequency drive delivers precise motor speed and torque control under rigorous process conditions. In continuous-duty environments like chemical processing, water treatment, and conveyor material handling, the VFD17AMS43ANSAA minimizes mechanical wear and prevents unscheduled downtime through its robust power architecture and integrated safety features. Its heavy-duty capability ensures reliable torque response even during sudden load spikes, making it an essential asset for optimizing plant floor efficiency.

Part Number Suffix Breakdown

Delta utilizes a precise alphanumeric coding system for the MS300 series to define the exact hardware layout:

  • VFD: Variable Frequency Drive (Product Category)

  • 17A: Rated output current of 17 Amps under Heavy Duty mode (150% overload for 6 seconds)

  • MS: MS300 Series (Standard Micro Drive)

  • 43: 460 V AC, 3-phase input voltage

  • A: IP20 protection rating level

  • N: No integrated EMC filter function

  • S: Built-in Safe Torque Off (STO) SIL2/PLd safety function

  • A: Standard installation type design

  • A: Standard version model code

Critical Engineering Parameters

The following specification table outlines the mechanical, environmental, and electrical parameters calibrated for industrial integration:

Parameter Specifications
Model VFD17AMS43ANSAA
Brand DELTA
Origin Taiwan
Drive Series MS300 Series
Control Mode V/f, SVC, FOC open loop, PM Sensorless
Input Voltage Range 380 V AC to 480 V AC (3-phase, 50/60 Hz)
Rated Output Current 17.0 A (Heavy Duty)
Safety Certification Safe Torque Off (STO) SIL2 / PLd
Protection Degree IP20 / UL Type 1
Operating Temperature -20 to 50 deg C (without derating)
Net Weight 2.07 kg
Shipping Weight 4.00 kg
Dimensions (W x H x D) Standard MS300 Frame C enclosure dimensions

Technical Knowledge Base & Common Inquiries

What specific safety certifications does the integrated STO function fulfill?

The built-in Safe Torque Off (STO) function complies with EN ISO 13849-1 Category 3 PLd and IEC 61508 SIL2 standards. It immediately cuts off power to the motor gate drives to prevent an unexpected startup, eliminating the need for external mechanical contactors in safety circuits.

Can this specific drive run permanent magnet motors, or is it limited to induction motors?

The MS300 platform supports both traditional asynchronous induction motors and high-efficiency permanent magnet (PM) synchronous motors via sensorless open-loop control mode.

What are the primary considerations when implementing this drive without an internal EMC filter?

Since this specific configuration lacks an internal EMC filter (designated by the "N" suffix), external line reactors or dedicated external EMC filters must be installed on the input lines if compliance with specific EN 61800-3 radio frequency interference standards is mandatory for the plant network.


Field Commissioning & Safety Guidelines

  • Thermal Management Airflow Spacing: For optimal heat dissipation, mount the IP20 chassis vertically on a flat, flame-resistant surface. Maintain a minimum clearance of 50 mm above and below the drive unit, and 30 mm on each side when operating at the maximum 50 deg C ambient rating.

  • Control Loop Shielding Protocol: All analog command wires and the STO safety circuit lines must use braided shielded cables with a coverage of at least 85%. Ground the shield only at the drive end using the provided grounding clamps to eliminate common-mode noise and ground loops.

  • Power Terminal Torques: Tighten all main line input terminals (R/L1, S/L2, T/L3) and motor output connections (U/T1, V/T2, W/T3) to the manufacturer-specified torque limits to prevent local overheating and erratic terminal voltages under heavy duty 17 A cycles

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

VFD17AMS43ANSAA

Stock & lead time on request

Call
1 su 1

DELTA VFD17AMS43ANSAA MS300 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: VFD17AMS43ANSAA

  • Country of origin:United States

  • Product Type: MS300 Series Variable Frequency Drive

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Market-Leading Motor Control Overview

The VFD17AMS43ANSAA (VFD17AMS43ANSAA) is a high-performance standard micro drive engineered by Delta for demanding industrial automation applications. Operating as a core component within the globally trusted MS300 Series, this compact variable frequency drive delivers precise motor speed and torque control under rigorous process conditions. In continuous-duty environments like chemical processing, water treatment, and conveyor material handling, the VFD17AMS43ANSAA minimizes mechanical wear and prevents unscheduled downtime through its robust power architecture and integrated safety features. Its heavy-duty capability ensures reliable torque response even during sudden load spikes, making it an essential asset for optimizing plant floor efficiency.

Part Number Suffix Breakdown

Delta utilizes a precise alphanumeric coding system for the MS300 series to define the exact hardware layout:

  • VFD: Variable Frequency Drive (Product Category)

  • 17A: Rated output current of 17 Amps under Heavy Duty mode (150% overload for 6 seconds)

  • MS: MS300 Series (Standard Micro Drive)

  • 43: 460 V AC, 3-phase input voltage

  • A: IP20 protection rating level

  • N: No integrated EMC filter function

  • S: Built-in Safe Torque Off (STO) SIL2/PLd safety function

  • A: Standard installation type design

  • A: Standard version model code

Critical Engineering Parameters

The following specification table outlines the mechanical, environmental, and electrical parameters calibrated for industrial integration:

Parameter Specifications
Model VFD17AMS43ANSAA
Brand DELTA
Origin Taiwan
Drive Series MS300 Series
Control Mode V/f, SVC, FOC open loop, PM Sensorless
Input Voltage Range 380 V AC to 480 V AC (3-phase, 50/60 Hz)
Rated Output Current 17.0 A (Heavy Duty)
Safety Certification Safe Torque Off (STO) SIL2 / PLd
Protection Degree IP20 / UL Type 1
Operating Temperature -20 to 50 deg C (without derating)
Net Weight 2.07 kg
Shipping Weight 4.00 kg
Dimensions (W x H x D) Standard MS300 Frame C enclosure dimensions

Technical Knowledge Base & Common Inquiries

What specific safety certifications does the integrated STO function fulfill?

The built-in Safe Torque Off (STO) function complies with EN ISO 13849-1 Category 3 PLd and IEC 61508 SIL2 standards. It immediately cuts off power to the motor gate drives to prevent an unexpected startup, eliminating the need for external mechanical contactors in safety circuits.

Can this specific drive run permanent magnet motors, or is it limited to induction motors?

The MS300 platform supports both traditional asynchronous induction motors and high-efficiency permanent magnet (PM) synchronous motors via sensorless open-loop control mode.

What are the primary considerations when implementing this drive without an internal EMC filter?

Since this specific configuration lacks an internal EMC filter (designated by the "N" suffix), external line reactors or dedicated external EMC filters must be installed on the input lines if compliance with specific EN 61800-3 radio frequency interference standards is mandatory for the plant network.


Field Commissioning & Safety Guidelines

  • Thermal Management Airflow Spacing: For optimal heat dissipation, mount the IP20 chassis vertically on a flat, flame-resistant surface. Maintain a minimum clearance of 50 mm above and below the drive unit, and 30 mm on each side when operating at the maximum 50 deg C ambient rating.

  • Control Loop Shielding Protocol: All analog command wires and the STO safety circuit lines must use braided shielded cables with a coverage of at least 85%. Ground the shield only at the drive end using the provided grounding clamps to eliminate common-mode noise and ground loops.

  • Power Terminal Torques: Tighten all main line input terminals (R/L1, S/L2, T/L3) and motor output connections (U/T1, V/T2, W/T3) to the manufacturer-specified torque limits to prevent local overheating and erratic terminal voltages under heavy duty 17 A cycles

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...