Emerson

Emerson VE4006P2 KJ3241X1-BA1 M-series Serial Interface Card

SKU VE4006P2 KJ3241X1-BA1

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Emerson
  • Product No.: VE4006P2 KJ3241X1-BA1
  • Origin United States
  • Product Type: Serial Interface Card
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.18 kg
  • Dimensions: 5.1cm x 12.7cm x 12.7cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson VE4006P2 KJ3241X1-BA1 M-series Serial Interface Card

Quantità

Product Description

Description

The Emerson KJ3241X1-BA1 (also referred to as VE4006P2) is a Serial Interface Card designed for the DeltaV M-series automation platform. This Series-2 module features two communication ports, enabling integration with various field devices through multiple protocols. It supports RS232, RS422/485 half-duplex, and RS422/485 full-duplex communication, providing flexibility for industrial data exchange. Each port is electrically isolated from the system and other ports to ensure signal integrity and protection in demanding process environments.

Features

  • M-series Serial Interface Card with 2-port configuration
  • Includes 1 Interface Card and 1 simplex Terminal Block
  • Supports RS232, RS422/485 half-duplex, and full-duplex communication
  • Electrical isolation between ports and the system
  • Configurable parity: Even, Odd, or None
  • Rotational keying system (Key Pos: D4) for terminal block compatibility
  • Supports up to 32 data sets (16 per port)

Applications

  • Distributed Control Systems (DCS)
  • Process automation and industrial communication
  • Field device integration and serial data acquisition
  • Supervisory control and data monitoring

Technical Specifications

Parameter Specification
Model KJ3241X1-BA1 (VE4006P2)
Brand Emerson DeltaV
Product Type M-series Serial Interface Card
Ports 2
Port Types RS232, RS422/485 half duplex, RS422/485 full duplex
Data Sets 32 (16 per port)
Baud Rates 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity Even, Odd, None
Isolation Each port isolated from system and other ports
Operating Temperature -40 to 70 Celsius
Storage Temperature -40 to 85 Celsius
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP 20
Terminal Block Key D 4

Installation Guidelines

  • This unit cannot be removed or inserted with system power energized in hazardous areas.
  • A rotary keying system ensures compatibility between the I/O card and terminal block; verify the keys are set correctly before installation.
  • Ensure all ports are externally grounded as per system requirements to maintain isolation performance.
  • Refer to document 12P2046 for specific instructions regarding installation and operation in hazardous areas.

Compliance and Certifications

  • ATEX: II 3G Ex nA nC IIC Gc (FM12ATEX0090U)
  • IECEx: IECEX FMG 12.0035U
  • FM: CL. 1 Div. 2, GP. A, B, C, D (Temp. Rating T4)
  • CE: Approved
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Can the module be inserted while the system power is energized?
No, the module cannot be removed or inserted with system power energized unless the area is known to be non-hazardous.
What port types are supported by this device?
The module supports RS232, RS422/485 half-duplex, and RS422/485 full-duplex communication.
How do I ensure the terminal block matches the I/O card?
A rotary keying system (Key Pos: D4) is used to ensure compatibility. The terminal block must have its keys set to match the specific I/O card.
Are the ports isolated?
Yes, each port is electrically isolated from the system and from the other port. Note that these ports must be externally grounded.
Reviews

VE4006P2 KJ3241X1-BA1

Stock & lead time on request

Call
1 su 3

Emerson VE4006P2 KJ3241X1-BA1 M-series Serial Interface Card

Only 4 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: VE4006P2 KJ3241X1-BA1

  • Country of origin:United States

  • Product Type: Serial Interface Card

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 5.1cm x 12.7cm x 12.7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Emerson KJ3241X1-BA1 (also referred to as VE4006P2) is a Serial Interface Card designed for the DeltaV M-series automation platform. This Series-2 module features two communication ports, enabling integration with various field devices through multiple protocols. It supports RS232, RS422/485 half-duplex, and RS422/485 full-duplex communication, providing flexibility for industrial data exchange. Each port is electrically isolated from the system and other ports to ensure signal integrity and protection in demanding process environments.

Features

  • M-series Serial Interface Card with 2-port configuration
  • Includes 1 Interface Card and 1 simplex Terminal Block
  • Supports RS232, RS422/485 half-duplex, and full-duplex communication
  • Electrical isolation between ports and the system
  • Configurable parity: Even, Odd, or None
  • Rotational keying system (Key Pos: D4) for terminal block compatibility
  • Supports up to 32 data sets (16 per port)

Applications

  • Distributed Control Systems (DCS)
  • Process automation and industrial communication
  • Field device integration and serial data acquisition
  • Supervisory control and data monitoring

Technical Specifications

Parameter Specification
Model KJ3241X1-BA1 (VE4006P2)
Brand Emerson DeltaV
Product Type M-series Serial Interface Card
Ports 2
Port Types RS232, RS422/485 half duplex, RS422/485 full duplex
Data Sets 32 (16 per port)
Baud Rates 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity Even, Odd, None
Isolation Each port isolated from system and other ports
Operating Temperature -40 to 70 Celsius
Storage Temperature -40 to 85 Celsius
Relative Humidity 5 to 95%, non-condensing
Protection Rating IP 20
Terminal Block Key D 4

Installation Guidelines

  • This unit cannot be removed or inserted with system power energized in hazardous areas.
  • A rotary keying system ensures compatibility between the I/O card and terminal block; verify the keys are set correctly before installation.
  • Ensure all ports are externally grounded as per system requirements to maintain isolation performance.
  • Refer to document 12P2046 for specific instructions regarding installation and operation in hazardous areas.

Compliance and Certifications

  • ATEX: II 3G Ex nA nC IIC Gc (FM12ATEX0090U)
  • IECEx: IECEX FMG 12.0035U
  • FM: CL. 1 Div. 2, GP. A, B, C, D (Temp. Rating T4)
  • CE: Approved

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson VE4006P2 KJ3241X1-BA1 M-series Serial Interface Card

Can the module be inserted while the system power is energized?

No, the module cannot be removed or inserted with system power energized unless the area is known to be non-hazardous.

What port types are supported by this device?

The module supports RS232, RS422/485 half-duplex, and RS422/485 full-duplex communication.

How do I ensure the terminal block matches the I/O card?

A rotary keying system (Key Pos: D4) is used to ensure compatibility. The terminal block must have its keys set to match the specific I/O card.

Are the ports isolated?

Yes, each port is electrically isolated from the system and from the other port. Note that these ports must be externally grounded.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

All'interno della CPU del PLC: cicli di scansione, memoria e selezione

Una guida pratica di ingegneria al funzionamento della CPU di un PLC, dai cicli di scansione deterministici e dalle tabelle delle immagini degli I/O fino a memoria, comunicazioni, diagnostica,...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.