The DS3800DMPK1E1D operates as a specialized control assembly engineered for the Mark IV Speedtronic turbine management network. This generator regulator board monitors and normalizes synchronous excitation profiles to safeguard terminal voltage stability and power factor performance across industrial turbine-driven generator architectures.

The microprocessing layout of the DS3800DMPK1E1D integrates 14 embedded sockets designed to house erasable programmable read-only memory (EPROM) modules, which retain local regulatory algorithms and parameter constants. Inter-module communication and diagnostic routing are managed via two 34-pin ribbon cables alongside two independent single-pin connector endpoints to secure clean integration with surrounding drive cabinets. To facilitate precise on-site hardware adaptation, the board incorporates 17 physical hardware jumpers that determine routing priorities across the internal logic tracks. Due to the high static sensitivity of the firmware modules and semiconductor components, specialized electrostatic mitigation protocols must be enforced during active retrofitting procedures.

Features

  • High-Density Firmware Framework: Populated with 14 onboard IC sockets supporting changeable EPROM modules to preserve distinct generator regulation code.
  • Dual Ribbon Cable Interfaces: Features two integrated 34-pin ribbon cable assemblies to transmit structured data paths directly to secondary drive modules.
  • Extensive Jumper Matrix: Equipped with 17 manual configuration jumpers to modify circuit routing vectors between predefined terminal pins.
  • Dedicated Synchronous Regulation: Specifically engineered to provide precise feedback processing loops required by Mark IV steam or gas turbine applications.

Applications

  • Generator Excitation Voltage Regulation: Controls terminal voltage limits and reactive power flows on utility-scale generator sets.
  • Speedtronic Loop Customization: Deployed within turbine control cabinets requiring localized hardware configuration adjustment via manual jumper setups.
  • Industrial Synchronous Motor Management: Stabilizes parameter variations across heavy industrial co-generation plant networks.

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model DS3800DMPK1E1D
Product Series Mark IV Speedtronic Series
Module Type Generator Regulator Board
Firmware Storage 14 EPROM Module Sockets (Shipped unpopulated)
Ribbon Connectors Two 34-pin Ribbon Cables
Discrete Interfaces 2 Single-pin Connectors
Jumper Matrix 17 Configurable Jumpers
Country of Origin USA

Connections/Interfaces

Connection Block Type Function
Ribbon Cables (x2) 34-Pin Ribbon Assemblies Links regulatory logic circuits to complementary drive subdivisions
Single-Pin Connectors (x2) Single-Pin Terminals Discrete auxiliary grounding or signal tracking lines

Installation Guidelines

  • Enclosure Power Isolation: Completely de-energize and lock out all upstream electrical source lines feeding the active drive panel prior to handling the internal assembly components.
  • Firmware Extraction Control: Use a flat-blade screwdriver to gently lift the EPROM modules free of their embedded sockets by rocking the blade at either end. Place memory components immediately into an ESD protective bag to avoid static corruption.
  • Jumper Configuration Mapping: Examine the defective assembly and map the precise arrangement of all 17 jumpers (e.g., covering pins 1 and 2, or pins 2 and 3) before moving the replacement unit's jumpers to match identically.
  • Static Protective Handling: Place the replacement circuit card flat on a certified static-dissipative work surface or a flattened anti-static shielding bag throughout the module insertion process. Ensure the memory packages are pressed down for complete socket connection.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Are the EPROM firmware modules pre-installed on the replacement board?
No. The replacement board comes without the EPROM modules populated. Technicians must safely migrate the existing firmware modules from the old board into the embedded sockets of the replacement unit.
What is the function of the 17 hardware jumpers on the DS3800DMPK1E1D?
The jumpers are utilized to manually reconfigure and adapt the board circuitry to align with specific operation thresholds within the drive system.
How should the EPROM modules be handled to prevent data corruption?
Memory modules must be carefully extracted using a flat-blade tool and placed immediately inside a static-protective bag, as ambient electrostatic discharge can easily corrupt the internal data.
Reviews

DS3800DMPK1E1D

Stock & lead time on request

Call
1 su 3

GE DS3800DMPK1E1D Mark IV Generator Regulator Board

Only 6 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: DS3800DMPK1E1D

  • Country of origin:United States

  • Product Type: Generator Regulator Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 220g

  • Dimensions: 17.8cm x 15.2cm x 1cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The DS3800DMPK1E1D operates as a specialized control assembly engineered for the Mark IV Speedtronic turbine management network. This generator regulator board monitors and normalizes synchronous excitation profiles to safeguard terminal voltage stability and power factor performance across industrial turbine-driven generator architectures.

The microprocessing layout of the DS3800DMPK1E1D integrates 14 embedded sockets designed to house erasable programmable read-only memory (EPROM) modules, which retain local regulatory algorithms and parameter constants. Inter-module communication and diagnostic routing are managed via two 34-pin ribbon cables alongside two independent single-pin connector endpoints to secure clean integration with surrounding drive cabinets. To facilitate precise on-site hardware adaptation, the board incorporates 17 physical hardware jumpers that determine routing priorities across the internal logic tracks. Due to the high static sensitivity of the firmware modules and semiconductor components, specialized electrostatic mitigation protocols must be enforced during active retrofitting procedures.

Features

  • High-Density Firmware Framework: Populated with 14 onboard IC sockets supporting changeable EPROM modules to preserve distinct generator regulation code.
  • Dual Ribbon Cable Interfaces: Features two integrated 34-pin ribbon cable assemblies to transmit structured data paths directly to secondary drive modules.
  • Extensive Jumper Matrix: Equipped with 17 manual configuration jumpers to modify circuit routing vectors between predefined terminal pins.
  • Dedicated Synchronous Regulation: Specifically engineered to provide precise feedback processing loops required by Mark IV steam or gas turbine applications.

Applications

  • Generator Excitation Voltage Regulation: Controls terminal voltage limits and reactive power flows on utility-scale generator sets.
  • Speedtronic Loop Customization: Deployed within turbine control cabinets requiring localized hardware configuration adjustment via manual jumper setups.
  • Industrial Synchronous Motor Management: Stabilizes parameter variations across heavy industrial co-generation plant networks.

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model DS3800DMPK1E1D
Product Series Mark IV Speedtronic Series
Module Type Generator Regulator Board
Firmware Storage 14 EPROM Module Sockets (Shipped unpopulated)
Ribbon Connectors Two 34-pin Ribbon Cables
Discrete Interfaces 2 Single-pin Connectors
Jumper Matrix 17 Configurable Jumpers
Country of Origin USA

Connections/Interfaces

Connection Block Type Function
Ribbon Cables (x2) 34-Pin Ribbon Assemblies Links regulatory logic circuits to complementary drive subdivisions
Single-Pin Connectors (x2) Single-Pin Terminals Discrete auxiliary grounding or signal tracking lines

Installation Guidelines

  • Enclosure Power Isolation: Completely de-energize and lock out all upstream electrical source lines feeding the active drive panel prior to handling the internal assembly components.
  • Firmware Extraction Control: Use a flat-blade screwdriver to gently lift the EPROM modules free of their embedded sockets by rocking the blade at either end. Place memory components immediately into an ESD protective bag to avoid static corruption.
  • Jumper Configuration Mapping: Examine the defective assembly and map the precise arrangement of all 17 jumpers (e.g., covering pins 1 and 2, or pins 2 and 3) before moving the replacement unit's jumpers to match identically.
  • Static Protective Handling: Place the replacement circuit card flat on a certified static-dissipative work surface or a flattened anti-static shielding bag throughout the module insertion process. Ensure the memory packages are pressed down for complete socket connection.

Are the EPROM firmware modules pre-installed on the replacement board?

No. The replacement board comes without the EPROM modules populated. Technicians must safely migrate the existing firmware modules from the old board into the embedded sockets of the replacement unit.

What is the function of the 17 hardware jumpers on the DS3800DMPK1E1D?

The jumpers are utilized to manually reconfigure and adapt the board circuitry to align with specific operation thresholds within the drive system.

How should the EPROM modules be handled to prevent data corruption?

Memory modules must be carefully extracted using a flat-blade tool and placed immediately inside a static-protective bag, as ambient electrostatic discharge can easily corrupt the internal data.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...