Honeywell

Honeywell 900S50-0460 HC900 I/O Scanner Module

SKU 900S50-0460

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 900S50-0460
  • Origin United States
  • Product Type: I/O Scanner Modules
  • Payment: T/T, Western Union
  • Weight: 0.36 kg
  • Dimensions: 137mm H x 38.1mm W 5.4" H* x 1.5" W
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

To establish high-speed communications between remote expansion racks and central controllers, the Honeywell 900S50-0460 is engineered for integrated use within the HC900 Process Controller architecture. This I/O scanner module coordinates distributed signal processing over industrial networks, providing robust connectivity and diagnostic feedback for remote modules. By utilizing Ethernet physical layer standards, the unit ensures high throughput and low-latency data acquisition across demanding industrial control environments.

Features

  • Provides high-speed interfaces for remote HC900 expansion racks.
  • Utilizes IEEE 802.3 Ethernet 100Base-TX physical layer connection.
  • Equipped with front-panel diagnostic LED indicators showing module and port status.
  • Designed for low power draw on the internal backplane with a maximum 770 mA loading at 5V.
  • Supports secure rack installation with direct backplane connection slots.

Applications

  • Distributed process control systems (DCS).
  • Thermal processing, industrial furnace, and oven management systems.
  • Water treatment plants and municipal infrastructure.
  • Boiler and steam generation system monitoring.

Technical Specifications

Manufacturer Honeywell
Part Number/Model 900S50-0460
Series HC900 Control System
Module Type I/O Scanner Module
Connection Interface IEEE 802.3 Ethernet 100Base-TX Physical Layer
Scanner Status Indicators Red/Green LED (indicates run mode or system error)
Expansion I/O Port Indicators Green and Yellow LEDs (indicates receive/transmit communication)
Power Supply Loading 5V DC; 770 mA maximum
Dimensions 137 mm H x 38.1 mm W
Weight 0.36 kg

Connections and Interfaces

Connector / Interface Function Description
RJ45 Expansion Port 100Base-TX communication interface back to host controller
Front-Panel LEDs Module diagnostics and real-time network traffic indicators

Installation Guidelines

  • Power Isolation: Always isolate and disconnect the rack power supply before inserting or extracting the scanner module from the backplane.
  • Chassis Alignment: Slide the module carefully into the designated controller rack slot to avoid damaging the rear connector pins. Secure the retaining screws.
  • Cable Shielding: Use high-quality shielded Ethernet cables (CAT5e or higher) to protect the diagnostic communications link from electromagnetic interference (EMI).
  • Grounding: Ensure the mounting rack is connected to a low-impedance industrial system ground point.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell 900S50-0460 module?
The Honeywell 900S50-0460 is an I/O scanner module that acts as the communication interface between remote expansion I/O racks and the central HC900 controller.
What standard protocol does this scanner module use for communication?
It utilizes the IEEE 802.3 Ethernet 100Base-TX physical layer protocol for communication.
What are the power requirements of the 900S50-0460?
The module requires a 5V DC power supply loading from the backplane, drawing a maximum of 770 mA.
What diagnostics do the front panel LEDs provide?
The scanner LED indicates the operational mode or system errors in Red/Green, while the expansion port LEDs indicate receive and transmit activity in Green and Yellow.
Reviews

900S50-0460

Stock & lead time on request

Call
1 su 1

Honeywell 900S50-0460 HC900 I/O Scanner Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 900S50-0460

  • Country of origin:United States

  • Product Type: I/O Scanner Modules

  • Payment: T/T, Western Union

  • Weight: 360g

  • Dimensions: 137mm H x 38.1mm W 5.4" H* x 1.5" W

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

To establish high-speed communications between remote expansion racks and central controllers, the Honeywell 900S50-0460 is engineered for integrated use within the HC900 Process Controller architecture. This I/O scanner module coordinates distributed signal processing over industrial networks, providing robust connectivity and diagnostic feedback for remote modules. By utilizing Ethernet physical layer standards, the unit ensures high throughput and low-latency data acquisition across demanding industrial control environments.

Features

  • Provides high-speed interfaces for remote HC900 expansion racks.
  • Utilizes IEEE 802.3 Ethernet 100Base-TX physical layer connection.
  • Equipped with front-panel diagnostic LED indicators showing module and port status.
  • Designed for low power draw on the internal backplane with a maximum 770 mA loading at 5V.
  • Supports secure rack installation with direct backplane connection slots.

Applications

  • Distributed process control systems (DCS).
  • Thermal processing, industrial furnace, and oven management systems.
  • Water treatment plants and municipal infrastructure.
  • Boiler and steam generation system monitoring.

Technical Specifications

Manufacturer Honeywell
Part Number/Model 900S50-0460
Series HC900 Control System
Module Type I/O Scanner Module
Connection Interface IEEE 802.3 Ethernet 100Base-TX Physical Layer
Scanner Status Indicators Red/Green LED (indicates run mode or system error)
Expansion I/O Port Indicators Green and Yellow LEDs (indicates receive/transmit communication)
Power Supply Loading 5V DC; 770 mA maximum
Dimensions 137 mm H x 38.1 mm W
Weight 0.36 kg

Connections and Interfaces

Connector / Interface Function Description
RJ45 Expansion Port 100Base-TX communication interface back to host controller
Front-Panel LEDs Module diagnostics and real-time network traffic indicators

Installation Guidelines

  • Power Isolation: Always isolate and disconnect the rack power supply before inserting or extracting the scanner module from the backplane.
  • Chassis Alignment: Slide the module carefully into the designated controller rack slot to avoid damaging the rear connector pins. Secure the retaining screws.
  • Cable Shielding: Use high-quality shielded Ethernet cables (CAT5e or higher) to protect the diagnostic communications link from electromagnetic interference (EMI).
  • Grounding: Ensure the mounting rack is connected to a low-impedance industrial system ground point.

What is the primary function of the Honeywell 900S50-0460 module?

The Honeywell 900S50-0460 is an I/O scanner module that acts as the communication interface between remote expansion I/O racks and the central HC900 controller.

What standard protocol does this scanner module use for communication?

It utilizes the IEEE 802.3 Ethernet 100Base-TX physical layer protocol for communication.

What are the power requirements of the 900S50-0460?

The module requires a 5V DC power supply loading from the backplane, drawing a maximum of 770 mA.

What diagnostics do the front panel LEDs provide?

The scanner LED indicates the operational mode or system errors in Red/Green, while the expansion port LEDs indicate receive and transmit activity in Green and Yellow.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.