Direct connection between Honeywell chassis I/O modules and core system components is established using the FS-SICC-0001/L3 system interconnection cable. This high-integrity, double-shielded cable assembly is engineered to ensure robust, noise-resistant signal transmission within safety-critical and high-availability industrial automation environments. Featuring 20 conductors of AWG 22 (0.34 mm²) wire size, it delivers reliable electrical connectivity and superior EMI protection across critical control networks.

The FS-SICC-0001/L3 is a pre-fabricated cable assembly optimized for seamless integration with Honeywell Safety Manager and associated industrial I/O chassis, minimizing installation time and reducing field-termination wiring errors.

Features

  • Double-shielded construction to maximize protection against electromagnetic and radio-frequency interference (EMI/RFI).
  • Equipped with 20 high-quality AWG 22 (0.34 mm²) conductors for optimal signal integrity.
  • Factory-assembled and tested to meet rigid Honeywell industrial safety standards.
  • Durable, industrial-grade outer jacket with a nominal outer diameter of 9.93 mm.

Applications

  • Honeywell Safety Manager system integration
  • Chassis-to-chassis and chassis-to-field terminal block routing
  • Safety Instrumented Systems (SIS) and critical control loops

Technical Specifications

ParameterSpecification
Manufacturer Honeywell
Part Number/Model FS-SICC-0001/L3
Cable Type Series FS-SICC-0001/Lx
Conductor Configuration 20 x AWG 22 (0.34 mm²)
Shielding Double shielded
Outer Diameter (Nominal) 9.93 mm (0.39 in)
Cable Length 3 meters (9.84 feet)
Shipping Weight 2.0 kg (4.41 lbs)

Installation Guidelines

  • Ensure the cable routing path is free of sharp edges that could compromise the 9.93 mm outer protective sheath.
  • Observe the standard minimum bend radius guidelines for double-shielded instrumentation cables during installation.
  • Securely tighten any connector locking mechanisms to ensure a gas-tight, vibration-resistant connection at the chassis interface.
  • Verify that the cable shield is grounded in accordance with Honeywell Safety Manager engineering and grounding directives.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the length of the Honeywell FS-SICC-0001/L3 cable?
The FS-SICC-0001/L3 cable has a pre-terminated, factory-tested length of 3 meters.
What are the conductor and shielding specifications of this cable?
This cable features 20 conductors of AWG 22 (0.34 mm²) wire size and is double-shielded to protect against high-frequency electromagnetic interference.
What is the nominal outer diameter of the cable?
The nominal outer diameter of the FS-SICC-0001/L3 cable is 9.93 mm (0.39 inches).
Which automation systems is this interconnection cable compatible with?
The cable is specifically designed for Honeywell Safety Manager and chassis I/O module system assemblies.
Reviews

FS-SICC-0001/L3

Stock & lead time on request

Call
1 su 1

Honeywell FS-SICC-0001/L3 Safety Manager System Interconnection Cable

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FS-SICC-0001/L3

  • Country of origin:United States

  • Product Type: System Cables

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Direct connection between Honeywell chassis I/O modules and core system components is established using the FS-SICC-0001/L3 system interconnection cable. This high-integrity, double-shielded cable assembly is engineered to ensure robust, noise-resistant signal transmission within safety-critical and high-availability industrial automation environments. Featuring 20 conductors of AWG 22 (0.34 mm²) wire size, it delivers reliable electrical connectivity and superior EMI protection across critical control networks.

The FS-SICC-0001/L3 is a pre-fabricated cable assembly optimized for seamless integration with Honeywell Safety Manager and associated industrial I/O chassis, minimizing installation time and reducing field-termination wiring errors.

Features

  • Double-shielded construction to maximize protection against electromagnetic and radio-frequency interference (EMI/RFI).
  • Equipped with 20 high-quality AWG 22 (0.34 mm²) conductors for optimal signal integrity.
  • Factory-assembled and tested to meet rigid Honeywell industrial safety standards.
  • Durable, industrial-grade outer jacket with a nominal outer diameter of 9.93 mm.

Applications

  • Honeywell Safety Manager system integration
  • Chassis-to-chassis and chassis-to-field terminal block routing
  • Safety Instrumented Systems (SIS) and critical control loops

Technical Specifications

ParameterSpecification
Manufacturer Honeywell
Part Number/Model FS-SICC-0001/L3
Cable Type Series FS-SICC-0001/Lx
Conductor Configuration 20 x AWG 22 (0.34 mm²)
Shielding Double shielded
Outer Diameter (Nominal) 9.93 mm (0.39 in)
Cable Length 3 meters (9.84 feet)
Shipping Weight 2.0 kg (4.41 lbs)

Installation Guidelines

  • Ensure the cable routing path is free of sharp edges that could compromise the 9.93 mm outer protective sheath.
  • Observe the standard minimum bend radius guidelines for double-shielded instrumentation cables during installation.
  • Securely tighten any connector locking mechanisms to ensure a gas-tight, vibration-resistant connection at the chassis interface.
  • Verify that the cable shield is grounded in accordance with Honeywell Safety Manager engineering and grounding directives.

What is the length of the Honeywell FS-SICC-0001/L3 cable?

The FS-SICC-0001/L3 cable has a pre-terminated, factory-tested length of 3 meters.

What are the conductor and shielding specifications of this cable?

This cable features 20 conductors of AWG 22 (0.34 mm²) wire size and is double-shielded to protect against high-frequency electromagnetic interference.

What is the nominal outer diameter of the cable?

The nominal outer diameter of the FS-SICC-0001/L3 cable is 9.93 mm (0.39 inches).

Which automation systems is this interconnection cable compatible with?

The cable is specifically designed for Honeywell Safety Manager and chassis I/O module system assemblies.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.