Honeywell

Honeywell FTA-T-08 Fail-Safe Digital Output Relay FTA Module

SKU FTA-T-08

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: FTA-T-08
  • Origin United States
  • Product Type: Safety Relay Modules
  • Payment: T/T, Western Union
  • Weight: 1.5 kg
  • Dimensions: 5 x 20 mm (0.2 x 0.78 in) or 5 x 25 mm (0.2 x 0.98 in)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Engineered for high-integrity safety systems, the Honeywell FTA-T-08 is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA). Designed to interface directly with safety-critical control modules such as the 10201/2/1, this unit provides robust galvanic isolation and contact multiplication for critical process shutdown and safety interlock loops. Each of the four channels features a redundant, diverse relay configuration utilizing devices from different manufacturers to mitigate common-cause failures and comply with rigorous functional safety requirements.

The FTA-T-08 incorporates an integrated 3.15 AT slow-acting fuse on each normally open (NO) field contact, protecting field-side wiring and devices from unexpected overcurrent conditions. Local status diagnostics are indicated through on-board LEDs, facilitating prompt field troubleshooting. Connection to the primary controller rack is accomplished using specialized SIC-C-02 cables, maintaining optimal signal integrity across the termination assembly.

Features

  • Four independent fail-safe digital output relay channels.
  • Redundant contact architecture featuring diverse relays from separate manufacturers to prevent common-mode failures.
  • Individual channel protection via 3.15 AT slow-acting fuses on the output contacts.
  • Integrated diagnostic LEDs for real-time channel status monitoring.
  • Silver alloy contacts designed for reliable and durable switching.
  • Direct integration compatibility with Honeywell 10201/2/1 modules using SIC-C-02 cable assemblies.

Applications

  • Emergency Shutdown Systems (ESD) in petrochemical and refinery environments.
  • Burner Management Systems (BMS) in power utility plants.
  • Fire and Gas (F&G) mitigation control networks.
  • Critical safety interlock loops in chemical processing.

Technical Specifications

Manufacturer Honeywell
Part Number/Model FTA-T-08 (3410713)
Module Compatibility 10201/2/1
Number of Channels 4
Nominal Input Voltage 24 Vdc
Maximum Input Voltage 31 Vdc
Relay Cut-in Voltage 19 Vdc
Typical Input Current 50 mA at 24 Vdc
Maximum Output Current 3.15 A
Minimum Output Current 400 mA at 24 Vdc
Maximum Switched Voltage 250 Vac / 150 Vdc
Maximum Switched Load 1250 VA / 150 W
Maximum Switched Frequency 20 Hz
Contact Material Silver alloy
Fuse Rating 3.15 AT (slow-acting), 5 x 20 mm or 5 x 25 mm
Electrical Lifecycles 80,000 operations
Mechanical Lifecycles 5,000,000 operations
Operating Ambient Temperature -40 degC to +60 degC (-40 degF to +140 degF)
Shipping Weight 1.5 kg

Connections and Interfaces

Connection Interface Specification
Termination Type T10 terminal connection
FTA Connector 1 x 4F connector layout
System Interface Cable SIC-C-02
Signals per Cable 4/4 channels

Installation Guidelines

  • De-energize all power sources before handling, mounting, or wiring the Field Termination Assembly.
  • Mount the module securely on a standard DIN rail or enclosure backplate inside a dust-free, dry industrial cabinet.
  • Isolate and route the high-voltage relay wiring separately from low-voltage logic signal cables.
  • Confirm that the field load does not exceed the maximum rated capacity of the 3.15 AT internal fuses.
  • Maintain sufficient spacing between adjacent modules to ensure continuous convection cooling within the specified ambient temperature limits.

Compliance and Certifications

  • CE Compliant
  • TUV Safety Certified
  • UL Listed
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell FTA-T-08?
The FTA-T-08 is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA) designed for isolation and high-integrity switching in safety shutdown and interlock applications.
What makes the relay configuration in this module safety-oriented?
Each channel is built with a diverse pair of redundant relays from different manufacturers to minimize the risk of common-cause failures.
What type of overcurrent protection is installed on the FTA-T-08?
Each output channel features an individual 3.15 AT slow-acting fuse, compatible with standard sizes of 5 x 20 mm or 5 x 25 mm.
What are the operating temperature limits for the FTA-T-08?
The assembly is rated for operations in ambient temperatures ranging from -40 degC to +60 degC (-40 degF to +140 degF).
Reviews

FTA-T-08

Stock & lead time on request

Call
1 su 1

Honeywell FTA-T-08 Fail-Safe Digital Output Relay FTA Module

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FTA-T-08

  • Country of origin:United States

  • Product Type: Safety Relay Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 5 x 20 mm (0.2 x 0.78 in) or 5 x 25 mm (0.2 x 0.98 in)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Engineered for high-integrity safety systems, the Honeywell FTA-T-08 is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA). Designed to interface directly with safety-critical control modules such as the 10201/2/1, this unit provides robust galvanic isolation and contact multiplication for critical process shutdown and safety interlock loops. Each of the four channels features a redundant, diverse relay configuration utilizing devices from different manufacturers to mitigate common-cause failures and comply with rigorous functional safety requirements.

The FTA-T-08 incorporates an integrated 3.15 AT slow-acting fuse on each normally open (NO) field contact, protecting field-side wiring and devices from unexpected overcurrent conditions. Local status diagnostics are indicated through on-board LEDs, facilitating prompt field troubleshooting. Connection to the primary controller rack is accomplished using specialized SIC-C-02 cables, maintaining optimal signal integrity across the termination assembly.

Features

  • Four independent fail-safe digital output relay channels.
  • Redundant contact architecture featuring diverse relays from separate manufacturers to prevent common-mode failures.
  • Individual channel protection via 3.15 AT slow-acting fuses on the output contacts.
  • Integrated diagnostic LEDs for real-time channel status monitoring.
  • Silver alloy contacts designed for reliable and durable switching.
  • Direct integration compatibility with Honeywell 10201/2/1 modules using SIC-C-02 cable assemblies.

Applications

  • Emergency Shutdown Systems (ESD) in petrochemical and refinery environments.
  • Burner Management Systems (BMS) in power utility plants.
  • Fire and Gas (F&G) mitigation control networks.
  • Critical safety interlock loops in chemical processing.

Technical Specifications

Manufacturer Honeywell
Part Number/Model FTA-T-08 (3410713)
Module Compatibility 10201/2/1
Number of Channels 4
Nominal Input Voltage 24 Vdc
Maximum Input Voltage 31 Vdc
Relay Cut-in Voltage 19 Vdc
Typical Input Current 50 mA at 24 Vdc
Maximum Output Current 3.15 A
Minimum Output Current 400 mA at 24 Vdc
Maximum Switched Voltage 250 Vac / 150 Vdc
Maximum Switched Load 1250 VA / 150 W
Maximum Switched Frequency 20 Hz
Contact Material Silver alloy
Fuse Rating 3.15 AT (slow-acting), 5 x 20 mm or 5 x 25 mm
Electrical Lifecycles 80,000 operations
Mechanical Lifecycles 5,000,000 operations
Operating Ambient Temperature -40 degC to +60 degC (-40 degF to +140 degF)
Shipping Weight 1.5 kg

Connections and Interfaces

Connection Interface Specification
Termination Type T10 terminal connection
FTA Connector 1 x 4F connector layout
System Interface Cable SIC-C-02
Signals per Cable 4/4 channels

Installation Guidelines

  • De-energize all power sources before handling, mounting, or wiring the Field Termination Assembly.
  • Mount the module securely on a standard DIN rail or enclosure backplate inside a dust-free, dry industrial cabinet.
  • Isolate and route the high-voltage relay wiring separately from low-voltage logic signal cables.
  • Confirm that the field load does not exceed the maximum rated capacity of the 3.15 AT internal fuses.
  • Maintain sufficient spacing between adjacent modules to ensure continuous convection cooling within the specified ambient temperature limits.

Compliance and Certifications

  • CE Compliant
  • TUV Safety Certified
  • UL Listed

What is the primary function of the Honeywell FTA-T-08?

The FTA-T-08 is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA) designed for isolation and high-integrity switching in safety shutdown and interlock applications.

What makes the relay configuration in this module safety-oriented?

Each channel is built with a diverse pair of redundant relays from different manufacturers to minimize the risk of common-cause failures.

What type of overcurrent protection is installed on the FTA-T-08?

Each output channel features an individual 3.15 AT slow-acting fuse, compatible with standard sizes of 5 x 20 mm or 5 x 25 mm.

What are the operating temperature limits for the FTA-T-08?

The assembly is rated for operations in ambient temperatures ranging from -40 degC to +60 degC (-40 degF to +140 degF).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.

Filtraggio con media mobile nei sistemi di controllo analogico DCS e PLC

Un filtro a media mobile è lo smussatore a finestra scorrevole che la maggior parte degli ingegneri della strumentazione inserisce nei percorsi dei segnali analogici di DCS e PLC. Ecco come funziona...