Product Description

Description

Designed for integration with the Lenze 8200 vector frequency inverters, the E82ZAFCC200 serves as a specialized CAN-I/O communication module to facilitate decentralized fieldbus networking. This function module mounts directly onto the inverter's standard interface slot, enabling real-time data exchange, parameterization, and control command transmission via the CAN system bus. By integrating this module, operators can seamlessly connect their drive systems to centralized PLCs or distributed control networks, optimizing system response times and reducing wiring complexity in automated environments.

Features

  • Direct plug-in mounting onto Lenze 8200 vector frequency inverters.
  • Integrated CAN system bus interface for decentralized automation architectures.
  • Supports standard CAN communication protocols for multi-vendor system compatibility.
  • Enables remote parameter configuration, diagnostics, and real-time control of the drive.
  • Compact form factor designed for space-saving installation within the drive housing.

Applications

This communication module is widely utilized in industrial automation environments, including:

  • Conveyor and material handling systems
  • Packaging machinery
  • Automated production lines
  • Machine tool integration utilizing Lenze 8200 vector drives

Technical Specifications

Manufacturer Lenze
Part Number/Model E82ZAFCC200
Series 8200-series
Module Type CAN-I/O Communication Function Module
Weight 0.05 kg
Commodity Code 85044086
Compatibility Lenze 8200 Vector Inverters

Installation Guidelines

For safe and reliable operation, adhere to the following engineering guidelines during installation:

  • Ensure the frequency inverter is completely powered down and the DC-bus capacitors are fully discharged before inserting or removing the module.
  • Plug the E82ZAFCC200 module firmly into the dedicated function slot on the front of the 8200 vector inverter.
  • Secure the module using the integrated retaining screws to ensure reliable electrical contact and vibration resistance.
  • Route CAN bus cabling away from high-voltage motor cables to minimize electromagnetic interference (EMI).
  • Ensure proper termination resistors (120 ohms) are installed at both physical ends of the CAN network segment.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Lenze E82ZAFCC200?
The Lenze E82ZAFCC200 is a CAN-I/O communication function module designed to interface Lenze 8200 vector frequency inverters with a CAN system bus network for decentralized control and parameterization.
Which drive series is compatible with this communication module?
This module is specifically designed for use with the Lenze 8200-series vector frequency inverters.
Can the E82ZAFCC200 be hot-swapped while the inverter is powered?
No. The frequency inverter must be completely powered down, and the DC-bus capacitors must be fully discharged before installing or removing the E82ZAFCC200 module to prevent damage to the electronics.
Reviews

E82ZAFCC200

Stock & lead time on request

Call
1 su 6

Lenze E82ZAFCC200 8200-series Communication Module

Only 6 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: E82ZAFCC200

  • Country of origin:Germany

  • Product Type: Communication Modules

  • Barcode: 85044086

  • Payment: T/T, Western Union

  • Weight: 50g

  • Dimensions: 20cm x 15cm x 10cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for integration with the Lenze 8200 vector frequency inverters, the E82ZAFCC200 serves as a specialized CAN-I/O communication module to facilitate decentralized fieldbus networking. This function module mounts directly onto the inverter's standard interface slot, enabling real-time data exchange, parameterization, and control command transmission via the CAN system bus. By integrating this module, operators can seamlessly connect their drive systems to centralized PLCs or distributed control networks, optimizing system response times and reducing wiring complexity in automated environments.

Features

  • Direct plug-in mounting onto Lenze 8200 vector frequency inverters.
  • Integrated CAN system bus interface for decentralized automation architectures.
  • Supports standard CAN communication protocols for multi-vendor system compatibility.
  • Enables remote parameter configuration, diagnostics, and real-time control of the drive.
  • Compact form factor designed for space-saving installation within the drive housing.

Applications

This communication module is widely utilized in industrial automation environments, including:

  • Conveyor and material handling systems
  • Packaging machinery
  • Automated production lines
  • Machine tool integration utilizing Lenze 8200 vector drives

Technical Specifications

Manufacturer Lenze
Part Number/Model E82ZAFCC200
Series 8200-series
Module Type CAN-I/O Communication Function Module
Weight 0.05 kg
Commodity Code 85044086
Compatibility Lenze 8200 Vector Inverters

Installation Guidelines

For safe and reliable operation, adhere to the following engineering guidelines during installation:

  • Ensure the frequency inverter is completely powered down and the DC-bus capacitors are fully discharged before inserting or removing the module.
  • Plug the E82ZAFCC200 module firmly into the dedicated function slot on the front of the 8200 vector inverter.
  • Secure the module using the integrated retaining screws to ensure reliable electrical contact and vibration resistance.
  • Route CAN bus cabling away from high-voltage motor cables to minimize electromagnetic interference (EMI).
  • Ensure proper termination resistors (120 ohms) are installed at both physical ends of the CAN network segment.

What is the primary function of the Lenze E82ZAFCC200?

The Lenze E82ZAFCC200 is a CAN-I/O communication function module designed to interface Lenze 8200 vector frequency inverters with a CAN system bus network for decentralized control and parameterization.

Which drive series is compatible with this communication module?

This module is specifically designed for use with the Lenze 8200-series vector frequency inverters.

Can the E82ZAFCC200 be hot-swapped while the inverter is powered?

No. The frequency inverter must be completely powered down, and the DC-bus capacitors must be fully discharged before installing or removing the E82ZAFCC200 module to prevent damage to the electronics.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...