Siemens

Siemens 6AV7613-0AB20-0CF0 SIMATIC Panel PC 670

SKU 6AV7613-0AB20-0CF0

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6AV7613-0AB20-0CF0
  • Origin Germany
  • Product Type: Panel PC
  • Barcode: 85371091
  • Payment: T/T, Western Union
  • Weight: 0.012 kg
  • Dimensions: 0.1 x 0.1 x 0.1 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

This is a Siemens 6AV7613-0AB20-0CF0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit features a 12-inch TFT display with an integrated keypad for operator input. It is equipped with an Intel Celeron 300 MHz processor, 128 MB of RAM, and a 20 GB hard drive for data storage and application hosting. The system includes a CD-ROM drive and is pre-loaded with the Windows 98 operating system in English. This model is specified for a 115-230 V AC power supply and includes a European mains cable.

Features

  • 12-inch TFT color display with integrated keypad
  • Intel Celeron 300 MHz processor
  • 128 MB system RAM
  • 20 GB internal hard drive (HD)
  • Integrated CD-ROM optical drive
  • Pre-installed Windows 98 operating system (English)

Applications

  • Machine-level operator control and monitoring
  • Process visualization and data logging
  • Industrial data acquisition systems
  • Replacement for legacy HMI systems in manufacturing environments

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Part Number 6AV7613-0AB20-0CF0
Display 12-inch TFT with Keypad
Processor Intel Celeron 300 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive
Optical Drive CD-ROM
Operating System Windows 98 (English)
Input Voltage 115-230 V AC
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 0.1 x 0.1 x 0.1 cm
Harmonized Tariff Code 85371091
ECCN N (No License Required)

Installation Guidelines

CRITICAL WARNING: HAZARDOUS VOLTAGE

This equipment is powered by mains voltage (115-230 V AC), which can cause severe injury or death. All installation, maintenance, and troubleshooting procedures must be performed by qualified personnel only. Ensure the main power source is de-energized and locked-out/tagged-out (LOTO) before accessing terminals or making any connections.

  1. 1 Panel Cutout and Mounting: Prepare the control cabinet panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Secure the Panel PC using all provided mounting clamps, tightening them evenly to ensure a proper seal and prevent chassis distortion.
  2. 2 Protective Earth (PE) Connection: Connect the chassis ground terminal to the control cabinet's protective earth bus bar using a low-impedance conductor. This is a mandatory safety connection to protect against electric shock.
  3. 3 Power Supply Wiring: Connect the AC power source using the provided mains cable or an equivalent certified cable. Ensure the source voltage matches the 115-230 V AC rating. Use appropriate overcurrent protection (e.g., circuit breaker) as required by local electrical codes.
  4. 4 Ventilation and Clearance: Maintain adequate clearance around the rear of the unit for proper air circulation and heat dissipation. Do not block ventilation openings. Operating the unit in an environment exceeding its specified temperature range can lead to premature failure.
  5. 5 Initial Power-Up: After all connections are verified and the cabinet is secured, remove the LOTO device and apply power. Observe the boot sequence on the display to confirm the operating system loads correctly.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

6AV7613-0AB20-0CF0

Stock & lead time on request

Call
1 su 1

Siemens 6AV7613-0AB20-0CF0 SIMATIC Panel PC 670

Only 2 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AB20-0CF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 0.1 x 0.1 x 0.1 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

This is a Siemens 6AV7613-0AB20-0CF0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit features a 12-inch TFT display with an integrated keypad for operator input. It is equipped with an Intel Celeron 300 MHz processor, 128 MB of RAM, and a 20 GB hard drive for data storage and application hosting. The system includes a CD-ROM drive and is pre-loaded with the Windows 98 operating system in English. This model is specified for a 115-230 V AC power supply and includes a European mains cable.

Features

  • 12-inch TFT color display with integrated keypad
  • Intel Celeron 300 MHz processor
  • 128 MB system RAM
  • 20 GB internal hard drive (HD)
  • Integrated CD-ROM optical drive
  • Pre-installed Windows 98 operating system (English)

Applications

  • Machine-level operator control and monitoring
  • Process visualization and data logging
  • Industrial data acquisition systems
  • Replacement for legacy HMI systems in manufacturing environments

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Part Number 6AV7613-0AB20-0CF0
Display 12-inch TFT with Keypad
Processor Intel Celeron 300 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive
Optical Drive CD-ROM
Operating System Windows 98 (English)
Input Voltage 115-230 V AC
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 0.1 x 0.1 x 0.1 cm
Harmonized Tariff Code 85371091
ECCN N (No License Required)

Installation Guidelines

CRITICAL WARNING: HAZARDOUS VOLTAGE

This equipment is powered by mains voltage (115-230 V AC), which can cause severe injury or death. All installation, maintenance, and troubleshooting procedures must be performed by qualified personnel only. Ensure the main power source is de-energized and locked-out/tagged-out (LOTO) before accessing terminals or making any connections.

  1. 1 Panel Cutout and Mounting: Prepare the control cabinet panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Secure the Panel PC using all provided mounting clamps, tightening them evenly to ensure a proper seal and prevent chassis distortion.
  2. 2 Protective Earth (PE) Connection: Connect the chassis ground terminal to the control cabinet's protective earth bus bar using a low-impedance conductor. This is a mandatory safety connection to protect against electric shock.
  3. 3 Power Supply Wiring: Connect the AC power source using the provided mains cable or an equivalent certified cable. Ensure the source voltage matches the 115-230 V AC rating. Use appropriate overcurrent protection (e.g., circuit breaker) as required by local electrical codes.
  4. 4 Ventilation and Clearance: Maintain adequate clearance around the rear of the unit for proper air circulation and heat dissipation. Do not block ventilation openings. Operating the unit in an environment exceeding its specified temperature range can lead to premature failure.
  5. 5 Initial Power-Up: After all connections are verified and the cabinet is secured, remove the LOTO device and apply power. Observe the boot sequence on the display to confirm the operating system loads correctly.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.