SKU 6MF2101-1AB10-0AA0

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6MF2101-1AB10-0AA0
  • Origin Germany
  • Product Type: Remote Terminal Units
  • Barcode: 85371091
  • Payment: T/T, Western Union
  • Weight: 0.001 kg
  • Dimensions: 31.90cm x 33.50cm x 8.10cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

 

The 6MF2101-1AB10-0AA0 is a SICAM A8000 CP-8000 compact Remote Terminal Unit (RTU) engineered for high-availability telecontrol and automation applications. Designed for versatile use in energy supply systems and industrial infrastructure, this unit operates efficiently within a wide temperature range of -40 degC to +70 degC. The CP-8000 serves as a powerful processor module, enabling reliable data acquisition, processing, and communication in rugged environments.

Features

  • System Platform: SICAM A8000 series

  • Operating Voltage: 24-60V DC

  • Operating Temperature: -40 degC to +70 degC

  • Form Factor: Compact RTU design

  • Versatility: Suitable for telecontrol, smart grid, and industrial automation tasks

Applications

  • Electrical substation automation

  • Power distribution network monitoring

  • Smart grid and energy management systems

  • Industrial process monitoring and control

  • Telecontrol applications in harsh outdoor or indoor environments

Technical Specifications

Feature Specification
Manufacturer Siemens
Brand SICAM
Series A8000 CP-8000
Input Voltage 24-60V DC
Operating Temperature -40 degC to +70 degC
Product Phase Active
Dimensions (H x W x D) 31.90 x 33.50 x 8.10 cm
Weight 1.00 kg
Commodity Code 85371091
ECCN EAR99

Installation Guidelines

  • Mounting: Install the unit in an environment with sufficient airflow to ensure optimal heat dissipation. Ensure that the mounting surface is stable and vibration-resistant.

  • Power Supply: Verify that the supply voltage is within the specified 24-60V DC range before energizing the device.

  • Wiring: Use appropriate wire gauges for power and signal connections. Ensure all terminal connections are tightened according to industry standards.

  • Environment: The device is designed for extreme thermal conditions; however, ensure the installation area remains free of excessive conductive dust or moisture to maintain long-term reliability.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the operating temperature range for the CP-8000?
This unit is designed to operate in temperatures ranging from -40 degC to +70 degC.
What is the voltage input range for this RTU?
The device operates on a 24-60V DC supply.
Is this product currently in active production?
Yes, the 6MF2101-1AB10-0AA0 is currently in the active product phase.
Reviews

6MF2101-1AB10-0AA0

Stock & lead time on request

Call
1 su 1

Siemens 6MF2101-1AB10-0AA0 SICAM A8000 CP-8000 Compact RTU

Only 3 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6MF2101-1AB10-0AA0

  • Country of origin:Germany

  • Product Type: Remote Terminal Units

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 1g

  • Dimensions: 31.90cm x 33.50cm x 8.10cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

 

The 6MF2101-1AB10-0AA0 is a SICAM A8000 CP-8000 compact Remote Terminal Unit (RTU) engineered for high-availability telecontrol and automation applications. Designed for versatile use in energy supply systems and industrial infrastructure, this unit operates efficiently within a wide temperature range of -40 degC to +70 degC. The CP-8000 serves as a powerful processor module, enabling reliable data acquisition, processing, and communication in rugged environments.

Features

  • System Platform: SICAM A8000 series

  • Operating Voltage: 24-60V DC

  • Operating Temperature: -40 degC to +70 degC

  • Form Factor: Compact RTU design

  • Versatility: Suitable for telecontrol, smart grid, and industrial automation tasks

Applications

  • Electrical substation automation

  • Power distribution network monitoring

  • Smart grid and energy management systems

  • Industrial process monitoring and control

  • Telecontrol applications in harsh outdoor or indoor environments

Technical Specifications

Feature Specification
Manufacturer Siemens
Brand SICAM
Series A8000 CP-8000
Input Voltage 24-60V DC
Operating Temperature -40 degC to +70 degC
Product Phase Active
Dimensions (H x W x D) 31.90 x 33.50 x 8.10 cm
Weight 1.00 kg
Commodity Code 85371091
ECCN EAR99

Installation Guidelines

  • Mounting: Install the unit in an environment with sufficient airflow to ensure optimal heat dissipation. Ensure that the mounting surface is stable and vibration-resistant.

  • Power Supply: Verify that the supply voltage is within the specified 24-60V DC range before energizing the device.

  • Wiring: Use appropriate wire gauges for power and signal connections. Ensure all terminal connections are tightened according to industry standards.

  • Environment: The device is designed for extreme thermal conditions; however, ensure the installation area remains free of excessive conductive dust or moisture to maintain long-term reliability.

 

What is the operating temperature range for the CP-8000?

This unit is designed to operate in temperatures ranging from -40 degC to +70 degC.

What is the voltage input range for this RTU?

The device operates on a 24-60V DC supply.

Is this product currently in active production?

Yes, the 6MF2101-1AB10-0AA0 is currently in the active product phase.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...