Description

The Siemens 7ME6110-1MA20-2AA1 is a SITRANS FM MAG 1100 electromagnetic flow sensor featuring a wafer design with a DN 6 (1/4 inch) diameter. Engineered for accurate volumetric flow measurement of conductive liquids, this sensor is designed for industrial process applications in the water and wastewater, pharmaceutical, and chemical industries. Constructed with a ceramic liner and platinum electrodes, it is configured for remote transmitters (transmitter ordered separately) and includes a metric polyamide terminal box. It maintains an active product lifecycle status, delivering reliable performance for industrial fluid measurement architectures.

Features

  • SITRANS FM MAG 1100 electromagnetic flow sensor in a wafer design
  • Nominal diameter of DN 6 (1/4 inch) for precise fluid measurement
  • Ceramic liner equipped with platinum electrodes for chemical resistance
  • Designed for remote transmitter configurations (transmitter required separately)
  • Metric polyamide terminal box for secure signal wiring connection
  • Active product lifecycle status within the Siemens Sitrans range

Applications

  • Water and wastewater treatment flow monitoring
  • Chemical processing and dosing measurement lines
  • Pharmaceutical manufacturing fluid transfer loops
  • Industrial conductive liquid flow measurement systems

Technical Specifications

Specification Detail
Manufacturer Siemens
Brands Siemens
Range Sitrans
Type of Product Flow sensors
Product Phase Active
Weight 4.70 kg
Commodity Code 85389091
Export Control Regulations (ECCN) N

Connections/Interfaces

Port / Interface Type
Process Connection Wafer Design (DN 6 / 1/4 Inch)
Terminal Box Metric Polyamide Terminal Box

Installation Guidelines

  • Ensure the pipeline is completely depressurized and drained before installing or servicing the flow sensor.
  • Mount the wafer-style sensor securely between mating pipe flanges, ensuring correct alignment with the inner pipe diameter.
  • Observe proper flow direction arrows marked on the sensor body to guarantee accurate measurement readings.
  • Connect the sensor signal cable from the terminal box to a compatible remote transmitter, ensuring proper cable shielding.
  • Verify grounding and electrical continuity across the pipeline flanges prior to system operation.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the nominal diameter and design type of the 7ME6110-1MA20-2AA1 sensor?
It features a wafer design with a nominal diameter of DN 6 (1/4 inch).
What liner and electrode materials are utilized in this flow sensor?
It utilizes a ceramic liner equipped with platinum electrodes.
Is the transmitter included with this sensor unit?
No, the sensor is designed for remote transmitters which must be ordered separately.
Reviews

7ME6110-1MA20-2AA1

Stock & lead time on request

Call
1 su 1

Siemens Sitrans 7ME6110-1MA20-2AA1

Only 4 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 7ME6110-1MA20-2AA1

  • Country of origin:Germany

  • Product Type: Flow Sensors

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 4700g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Siemens 7ME6110-1MA20-2AA1 is a SITRANS FM MAG 1100 electromagnetic flow sensor featuring a wafer design with a DN 6 (1/4 inch) diameter. Engineered for accurate volumetric flow measurement of conductive liquids, this sensor is designed for industrial process applications in the water and wastewater, pharmaceutical, and chemical industries. Constructed with a ceramic liner and platinum electrodes, it is configured for remote transmitters (transmitter ordered separately) and includes a metric polyamide terminal box. It maintains an active product lifecycle status, delivering reliable performance for industrial fluid measurement architectures.

Features

  • SITRANS FM MAG 1100 electromagnetic flow sensor in a wafer design
  • Nominal diameter of DN 6 (1/4 inch) for precise fluid measurement
  • Ceramic liner equipped with platinum electrodes for chemical resistance
  • Designed for remote transmitter configurations (transmitter required separately)
  • Metric polyamide terminal box for secure signal wiring connection
  • Active product lifecycle status within the Siemens Sitrans range

Applications

  • Water and wastewater treatment flow monitoring
  • Chemical processing and dosing measurement lines
  • Pharmaceutical manufacturing fluid transfer loops
  • Industrial conductive liquid flow measurement systems

Technical Specifications

Specification Detail
Manufacturer Siemens
Brands Siemens
Range Sitrans
Type of Product Flow sensors
Product Phase Active
Weight 4.70 kg
Commodity Code 85389091
Export Control Regulations (ECCN) N

Connections/Interfaces

Port / Interface Type
Process Connection Wafer Design (DN 6 / 1/4 Inch)
Terminal Box Metric Polyamide Terminal Box

Installation Guidelines

  • Ensure the pipeline is completely depressurized and drained before installing or servicing the flow sensor.
  • Mount the wafer-style sensor securely between mating pipe flanges, ensuring correct alignment with the inner pipe diameter.
  • Observe proper flow direction arrows marked on the sensor body to guarantee accurate measurement readings.
  • Connect the sensor signal cable from the terminal box to a compatible remote transmitter, ensuring proper cable shielding.
  • Verify grounding and electrical continuity across the pipeline flanges prior to system operation.
Key Features:

What is the nominal diameter and design type of the 7ME6110-1MA20-2AA1 sensor?

It features a wafer design with a nominal diameter of DN 6 (1/4 inch).

What liner and electrode materials are utilized in this flow sensor?

It utilizes a ceramic liner equipped with platinum electrodes.

Is the transmitter included with this sensor unit?

No, the sensor is designed for remote transmitters which must be ordered separately.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...