1 daripada 3

Bently Nevada 135489-03 3500/42M I/O Module with Internal Barriers

Bently Nevada 135489-03 3500/42M I/O Module with Internal Barriers

Hanya 3 item tinggal dalam stok
  • Pengilang: Bently Nevada

  • No. Produk: 135489-03

  • Negara asal:Amerika Syarikat

  • Jenis Produk: I/O Module

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 460g

  • Dimensi: 241.3 mm x 24.4 mm x 163.1 mm (H x W x D)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The 135489-03 is a rear-slot I/O module with internal barriers designed for the Bently Nevada 3500/42M Proximitor Seismic Monitor system. It provides four channels of internal intrinsic safety barriers and internal termination wiring interfaces specifically configured for connection to Velomitor sensors on channels 1 through 4.

This module routes dynamic transducer signals to the 3500/42M main processing monitor while offering built-in galavanic and zener isolation circuits required for hazardous area installations. Operatives and plant engineers utilize the 135489-03 to monitor rotational vibration and velocity parameters on industrial machinery, passing critical static values and buffered signals to control systems, plant networks, and individual channel recorder outputs.

Features

  • Integrates four channels of internal intrinsic safety barriers for direct connection to Velomitor sensors.
  • Provides internal terminal strip connectors for field wiring termination.
  • Installs into a single full-height rear rack slot directly behind the 3500/42M main monitor board.
  • Includes independent analog recorder output connections for all four channel signals.
  • Certified for hazardous location installations under cNRTLus, ATEX, and IECEx requirements.

Applications

  • Continuous vibration and velocity monitoring for industrial pumps, fans, and electric motors
  • Compressor and steam turbine condition monitoring in hazardous process areas
  • Intrinsically safe field transducer signal conditioning for rotating machinery protection
  • Online 24/7 machinery protection in oil and gas, chemical, and power generation facilities

Ordering Information

Ordering Option Part Number Description Transducer Compatibility
AA: 06 135489-03

I/O Module with internal barriers, 

internal terminations, 4 x Velomitor

Velomitor on channels 1 through 4

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Part Number 135489-03
Module Type Barrier I/O Module (Internal Terminations)
Channel Configuration 4 x Velomitor
Operating Temperature 0 degC to +65 degC (32 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Rack Space Requirement 1 full-height rear slot
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)
Weight 0.46 kg (1.01 lb)
Seismic Barrier Vmax 27.25 V
Seismic Barrier Imax 91.8 mA
Seismic Barrier Rmin (PWR) 297 ohm

Connections and Interfaces

Terminal / Designation Function
PWR/B Transducer Power Supply
COM Transducer Common
SIG/A Transducer Signal Input
SHLD Cable Shield Connection
INHB Inhibit Input
RET Return
REC1 - REC4 Channel 1 to Channel 4 Recorder Outputs

Installation Guidelines

  • Insert the module into one full-height rear rack slot located directly behind the associated 3500/42M main processing monitor module.
  • Wire field sensor cables directly to the dedicated channel screw terminal header blocks.
  • Maintain proper grounding and shield termination according to installation drawing 138547 for hazardous area intrinsic safety compliance.
  • Ensure ambient operating conditions remain within the specified range of 0 degC to +65 degC.

Compliance and Certifications

  • cNRTLus: Class I, Zone 2: AEx/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (W/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF) when installed per drawing 138547
  • ATEX/IECEx: Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF) when installed per drawing 138547
  • EMC: European Community Directive 2014/30/EU (EN 61000-6-2, EN 61000-6-4)
  • Electrical Safety: European Community Directive 2014/35/EU (EN 61010-1)
  • RoHS: European Community Directive 2011/65/EU; China RoHS SJ/T 11364-2024
  • Maritime: ABS Marine and Offshore Applications; DNV GL Rules for Classification
  • FCC: Complies with Part 15 of the FCC Rules
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 135489-03 3500/42M I/O Module with Internal Barriers

Which transducers are compatible with this I/O module?

This module is configured with internal barriers to connect up to four Velomitor sensors across channels 1 through 4.

What is the operating temperature range for the device?

When used as an internal barrier I/O module with internal terminations, the operating temperature range is from 0 degC to +65 degC.

How many slots are required in the 3500 system rack?

The module requires one full-height rear slot in the 3500 rack system, positioned directly behind the main monitor card.

Does the module support hazardous area applications?

Yes, it contains internal intrinsic safety barriers and holds hazardous area approvals including cNRTLus, ATEX, and IECEx certifications.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Perak
Country of origin
Amerika Syarikat
Power source
Kuasa DC

Produk yang Baru Dilihat

Pengetahuan teknikal

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Memodenkan HMI Bailey INFI 90 Symphony yang Beroperasi pada OpenVMS Alpha

Panduan praktikal untuk menggantikan stesen pengendali Bailey Symphony yang sudah berusia dan berjalan pada OpenVMS Alpha. Panduan ini membandingkan emulasi Alpha, migrasi OpenVMS x86, pemindahan...

Mengapa Data Penyelenggaraan Penting untuk Kebolehpercayaan Industri

Data penyelenggaraan menghubungkan perintah kerja, isyarat penderia, sejarah aset, kos dan pengetahuan juruteknik. Jika digunakan dengan baik, data ini meningkatkan perancangan, kebolehpercayaan,...

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Bendalir: Panduan Praktikal Automasi Industri

Artikel ini menerangkan cara penggerak elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Artikel ini...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan cara sistem PLC melaksanakan operasi matematik asas seperti penambahan, penolakan, pendaraban, pembahagian, modulo dan pengkuasaan dalam automasi industri. Artikel ini...