1 daripada 1

Delta Electronics VFD370CP43B-21 CP2000 Series Fan/Pump Vector Control Drive

Delta Electronics VFD370CP43B-21 CP2000 Series Fan/Pump Vector Control Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Delta Electronics

  • No. Produk: VFD370CP43B-21

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 11000g

  • Dimensi: 250 mm x 400 mm x 210 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Providing dedicated torque control for centrifugal pumps and ventilation systems, the Delta Electronics VFD370CP43B-21 drives 37 kW (50 HP) motors with high efficiency. This CP2000 Series variable frequency drive utilizes sensorless vector control to optimize power consumption based on real-time load demand. With a robust 460V three-phase input rating and a continuous output capacity of 73 Amps, this unit integrates seamlessly into municipal water systems, industrial cooling towers, and commercial HVAC networks.

Features

  • Optimized V/f and sensorless vector control (SVC) curves for variable torque loads.
  • Built-in 10k steps PLC capacity to execute local logic without external controllers.
  • Integrated PID control with sleep, wake, and redirection functions for pressure and flow systems.
  • Multi-pump synchronous control mode supporting fixed-quantity and circulating configurations.
  • Robust IP20 / NEMA 1 physical protection rating suited for wall-mounted control panels.
  • MODBUS communication protocol embedded for direct network integration.

Applications

  • Wastewater treatment facility pumping stations.
  • Commercial HVAC air handling units and supply fans.
  • Industrial cooling tower fan modulation.
  • Constant pressure clean water supply networks.

Technical Specifications

Parameter Specification
Manufacturer Delta Electronics
Model Number VFD370CP43B-21
Product Series CP2000
Applicable Motor Capacity 37 kW / 50 HP
Rated Output Current 73 Amps
Input Voltage / Phase 460V AC, 3-Phase
Installation Type Wall Mount
Enclosure Rating IP20 / NEMA 1
Physical Dimensions (W x H x D) 250 mm x 400 mm x 210 mm (9.84 in x 15.75 in x 8.27 in)
Net Weight 10.0 kg (22.0 lbs)
Shipping Weight (Calculated) 11.0 kg (24.2 lbs)

Empirical Engineering Insights

Alternative Models & Compatibility

The CP2000 series features standardized terminal footprints across similar frame sizes. When replacing legacy VFD-F series units, confirm that existing PLC program configurations are migrated using Delta's VFDSoft software to ensure register compatibility. Note that control terminal logic can be switched between SINK and SOURCE via an internal jumper on the main control board.

Application Pitfalls & Engineering Notes

In fan applications experiencing high wind-milling effects (where the fan rotates even when unpowered), always enable the "Spin Start" (catch on the fly) parameters. Attempting to start the drive into a rotating load without spin start enabled will trigger overcurrent (OC) or overvoltage (OV) trip faults immediately upon startup.

Commissioning & Wiring Tips

To minimize electromagnetic interference (EMI) affecting the 4-20mA pressure transducer feedback signal, ensure all analog control lines use twisted-pair shielded cables grounded exclusively at the drive-end shield terminal. For long motor cable runs exceeding 50 meters, the installation of an output AC reactor is highly recommended to protect motor windings from dv/dt degradation.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage levels remain present inside the unit after input power is disconnected. Wait a minimum of 10 minutes for the internal DC bus capacitors to discharge fully before removing the drive cover or touching any wiring terminals. Confirm zero voltage using a calibrated multimeter.
1
Mechanical Mounting: Bolt the VFD securely to a flat, vertical surface using the rear wall-mount brackets. Ensure a minimum clearance of 150 mm above and below the chassis to allow unimpeded airflow through the heatsink.
2
Power Terminations: Connect the 460V 3-phase input lines to terminals R/L1, S/L2, and T/L3. Connect the motor leads to U/T1, V/T2, and W/T3. Ensure the ground wire is connected securely to the primary PE terminal.
3
Motor Auto-Tuning: Perform an rotational or static auto-tune run with the motor decoupled from the load to optimize internal vector control algorithm parameters.
Loading product navigation…

What is the primary application for the VFD370CP43B-21?

This drive is specifically designed for variable torque loads such as centrifugal pumps, fans, and blower systems in HVAC and water treatment applications.

Does this drive contain an integrated PLC?

Yes, the CP2000 series has a built-in PLC with a program capacity of up to 10k steps for localized process control and logic automation.

What protection standard does the VFD370CP43B-21 enclosure meet?

The drive meets IP20 and NEMA 1 protection standards, making it suitable for clean, indoor dry panel environments.

What should be done if the motor cable run exceeds 50 meters?

An output AC reactor must be installed between the VFD output terminals and the motor to suppress dv/dt voltage spikes and protect winding insulation.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...