Regulating industrial motor speed with exceptional torque control, the Mitsubishi Electric FR-A740-2.2K-CHT is a high-performance three-phase 400V variable frequency drive designed for heavy-duty applications. Part of the robust FR-A700 Series, this 2.2 kW (3 HP) inverter features advanced magnetic flux vector control and real sensorless vector control, ensuring stable speed regulation even at ultra-low frequencies. Engineered to survive harsh manufacturing environments, it serves as an essential automation component for precise machinery synchronization, fan/pump speed regulation, and torque-limiting applications.

Key Features

  • Real Sensorless Vector Control (RSV): Achieves high-accuracy torque and speed control without requiring an encoder feedback interface.
  • Offline Auto-Tuning: Automatically characterizes motor parameters to maximize performance across different motor brands.
  • Built-In Modbus RTU: Integrated RS-485 serial communication port supports standard industrial networking protocols.
  • Long-Life Design: Utilizes specialized cooling fans and capacitors rated for extended service lifetimes.
  • Integrated PLC Functionality: Allows custom logic control processing directly inside the drive using GX Developer software.

Applications

  • Conveyors and material handling distribution systems requiring high starting torque.
  • Industrial fan, blower, and exhaust ventilation systems.
  • Centrifugal pumps, booster stations, and fluid processing facilities.
  • Machine tool spindles, textile winding machines, and packaging equipment.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number FR-A740-2.2K-CHT
Product Series FR-A700 (A740 Class)
Input Voltage / Frequency 3-Phase 380 to 480 V AC, 50Hz / 60Hz
Applicable Motor Capacity 2.2 kW (3 Horsepower)
Output Current Rating 6.0 A (LD) / 5.0 A (HD)
Output Frequency Range 0.2 to 400 Hz
Control Modes Available V/F Control, Advanced Magnetic Flux Vector Control, Real Sensorless Vector Control
Enclosure Rating IP20 (Open Type)
Ambient Operating Temperature -10 to 50 degC (non-freezing)
Terminal Screw Size M3 x 35 mm (Control terminals)
Shipping Weight (Calculated) 4.0 kg (8.82 lbs)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A740-2.2K-CHT serves as a direct upgrade to the older FR-A540-2.2K series. For facilities transitioning to the newer FR-A840 series, the FR-A840-00126-2.6K is the designated replacement. When migrating configuration parameters, use the FR Configurator software to import and convert parameter tables seamlessly, but pay special attention to the terminal block mapping if relying on built-in PLC functions.

Application Pitfalls & Engineering Notes

In high-inertia fan applications, decelerating too rapidly can generate regenerative energy back into the drive, triggering an E.OV3 (Overvoltage during deceleration) safety fault. To prevent downtime under high-inertia loads, integrate a dedicated external braking resistor (FR-ABR-H2.2K) and ensure parameter 30 (Regenerative function selection) is configured correctly.

Commissioning & Wiring Tips

Always route the control signal wiring (using shielded twisted pair cables) completely separate from the main motor and power input lines to mitigate electro-magnetic interference (EMI). Terminal connections for control logical inputs are secure-clamp style; avoid using bare stranded copper wires without crimp ferrules, as this can lead to intermittent feedback signals.

Installation Guidelines

CRITICAL ELECTRICAL WARNING

Isolate and lock out all AC main line input feeds before attempting terminal wiring or mounting procedures. Internal DC-bus capacitors retain high-voltage charge after de-energization. Wait at least 10 minutes and verify with a reliable multimeter that the voltage across terminals P/+ and N/- is below 30 V DC before initiating hands-on physical contact.

1

Enclosure Mounting: Mount the inverter vertically onto a flat, non-flammable surface inside an electrical cabinet. Maintain a minimum horizontal spacing clearance of 50 mm and vertical clearance of 100 mm for unrestricted convective heat dissipation.

2

Power Connections: Connect the three-phase AC input supply to terminals R/L1, S/L2, and T/L3. Connect the output motor terminals to U, V, and W. Ensure the grounding terminal (PE) is securely bonded to the plant ground grid.

3

Startup Initialization: Turn on the input power. Set Parameter 9 (Electronic thermal O/L relay) to match the motor's rated plate current before executing any physical rotation tests.

What is the primary function of the CHT suffix on the FR-A740-2.2K-CHT?

The 'CHT' suffix designates a regional variation intended for the Chinese industrial market, utilizing Chinese language instruction material and labeling, while maintaining identical internal hardware, electrical performance, and parameter definitions as standard global FR-A740 models.

Does this model include a built-in dynamic braking transistor?

Yes, the FR-A740-2.2K-CHT contains a built-in braking transistor. However, for applications with high-inertia deceleration or heavy cyclic braking, you must install an external braking resistor across terminals P/+ and PR.

Can this drive run on a single-phase AC input supply?

No. The FR-A740-2.2K-CHT is strictly designed for three-phase AC input power (380 to 480 V AC, 50Hz/60Hz). Attempting to operate this unit on a single-phase source will trigger an input phase failure or under-voltage fault.

How do I clear an E.THT fault code on this inverter?

E.THT indicates an electronic thermal relay function trip (motor overload). Verify that the motor nameplate current matches Parameter 9, check for physical mechanical binding on the motor shaft, and ensure the load does not exceed the continuous output current limit of the drive.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...