1 daripada 1

Mitsubishi Electric FX5-32ET/ES MELSEC iQ-F Series Powered I/O Module

Mitsubishi Electric FX5-32ET/ES MELSEC iQ-F Series Powered I/O Module

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FX5-32ET/ES

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Powered I/O Modules

  • Pembayaran: T/T, Western Union

  • Berat: 650g

  • Dimensi: 150 mm x 90 mm x 83 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to expand the local control capacity of MELSEC iQ-F series programmable controllers, the FX5-32ET/ES extension block provides integrated power supply capabilities alongside high-density digital I/O interfaces. This powered extension module features a built-in AC power supply, which significantly reduces the current draw on the host CPU module's internal 5V DC and 24V DC buses, enabling complex system expansion without requiring additional power booster units.

The unit occupies 32 I/O points on the active PLC backplane, split evenly between inputs and outputs. The input stage contains 16 points configurable for either sink or source wiring configurations, while the output stage consists of 16 low-latency transistor outputs in a sink configuration, making it suitable for high-speed switching and interfacing with solid-state control components.

Features

  • Equipped with an onboard 100 to 240 V AC power supply to power downstream extension modules and field devices.
  • Provides 32 local digital I/O points (16 digital inputs and 16 transistor outputs) in a single compact enclosure.
  • Flexible digital inputs compatible with both 24 V DC sink and source signal wiring.
  • Reliable transistor outputs (sink type) designed for rapid duty cycles and maintenance-free solid-state switching.
  • Removable terminal blocks simplify installation, wiring, and routine system maintenance.
  • Direct connection to the FX5U CPU module or preceding expansion blocks via the integrated extension cable.

Applications

  • Automated assembly lines and material handling conveyor systems.
  • Packaging, wrapping, and labeling machinery.
  • Water and wastewater treatment control panels.
  • HVAC and environmental control cabinets.
  • Multi-axis motion control and positioning system expansions.

Technical Specifications

ManufacturerPart Number / ModelSeriesModule TypeOccupied I/O PointsPower Supply VoltageAllowable Voltage RangePower ConsumptionService Power SupplyInput PointsOutput PointsResponse Time (Inputs)Response Time (Outputs)Operating Ambient TemperatureStorage Ambient TemperatureDimensions (W x H x D)Weight
Mitsubishi Electric
FX5-32ET/ES
MELSEC iQ-F Series
Powered I/O Module (AC powered)
32 points (on PLC bus)
100 to 240 V AC (50/60 Hz)
85 to 264 V AC
25 W
24 V DC (310 mA maximum capacity)
16 points (24 V DC, sink/source configuration)
16 points (Transistor, sink configuration)
50 microseconds or less (OFF to ON / ON to OFF)
0.2 milliseconds or less
0 to 55 degC
-25 to 75 degC
150 mm x 90 mm x 83 mm
0.65 kg

Connections and Interfaces

Terminal Group Terminal Markings Function / Connection Description
Power Supply Terminals L, N, PE 100 to 240 V AC Power Line and Protective Earth Ground
Service Power Output 24+, 24- 24 V DC auxiliary power output for sensors/input devices
Digital Inputs (16 Points) S/S, X0 to X17 Sink/Source common terminal and digital inputs
Digital Outputs (16 Points) COM0, COM1, Y0 to Y17 Common terminals and transistor (sink) outputs

Installation Guidelines

  • Mounting: Mount the module on a standard 35 mm DIN rail or secure directly to a flat panel using the integrated mounting screw holes.
  • Spacing: Maintain a minimum clearance of 50 mm above and below the unit to promote natural convection cooling and prevent thermal stress.
  • Grounding: Connect the Protective Earth (PE) terminal to a dedicated ground point using a wire with a minimum cross-section of 2 mm squared. Ground resistance must be 100 Ohms or less.
  • Wiring: Use crimp terminals designed for M3 terminal screws. Tighten terminal screws to a torque spec of 0.5 to 0.8 N-m to prevent contact resistance or damage.

What is the primary function of the FX5-32ET/ES powered I/O module?

The FX5-32ET/ES expands the physical I/O capacity of a MELSEC iQ-F PLC system by 32 channels. Because it has an onboard AC power supply, it powers its own I/O channels and can supply auxiliary power to sensors, reducing the power load on the main CPU module.

Are the input terminals on the FX5-32ET/ES configurable for both NPN and PNP devices?

Yes. The 16 digital inputs feature a sink/source common terminal (S/S), allowing you to configure the module for either sink (NPN) or source (PNP) wiring.

What output type is used in the FX5-32ET/ES module?

This module is equipped with 16 transistor outputs in a sink configuration, making them suitable for high-speed, high-cycle switching of DC loads.

Can I use the auxiliary 24V DC terminal on this module to power external field devices?

Yes, the module provides a 24V DC service power output terminal with a maximum capacity of 310 mA to power local sensors and input switches.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...