1 z 1

DELTA AH10SCM-5A AH500 Series Serial Communication Module

DELTA AH10SCM-5A AH500 Series Serial Communication Module

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: AH10SCM-5A

  • Country of origin:Tajwan

  • Product Type: Network Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The AH10SCM-5A (AH10SCM5A) is a high-performance serial communication module designed for the Delta AH500 redundant rack-based PLC system. Engineered for complex multi-device networking, this module provides dual-channel RS-422/485 connectivity, enabling the PLC to act as a central coordinator in large-scale industrial architectures. With a focus on system resilience, the AH10SCM-5A features a full isolation design between power and signal circuits, ensuring that transient electrical noise from the field does not compromise the CPU's integrity. It is an essential component for applications requiring high-speed data exchange with Variable Frequency Drives (VFDs), sensors, and third-party instruments in sectors such as water treatment, HVAC (via BACnet), and smart manufacturing.

Technical Configuration

The AH10SCM-5A is a versatile Master/Slave communication hub supporting high-speed transmission up to 460.8 kbps. It is equipped with two independent serial ports that can be configured for various protocols, including Modbus RTU/ASCII and BACnet Slave. A key technical advantage is the "UD Link" (User Defined Link) capability, which allows engineers to customize communication formats for non-standard serial devices. Furthermore, the module supports hot-swapping, allowing for maintenance or replacement without shutting down the entire PLC rack, thereby maximizing system uptime in continuous processing environments.

Technical Specifications

Attribute Specification
Model AH10SCM-5A
Brand DELTA
Origin Taiwan
Module Type Serial Communication Module (RS-422 / RS-485)
Communication Ports 2 Ports
Max Baud Rate 460.8 kbps
Power Consumption 1.2 W (Internal)
Protocols Modbus RTU/ASCII, BACnet Slave, UD Link, PLC Link
Isolation Full isolation (Power and Signal)
Operating Temp -20 to 60 deg C
Special Features Hot-swapping, Automatic Data Exchange
Weight 0.5 kg (Shipping weight 2.0 kg)

Technical FAQs

Can the AH10SCM-5A manage data exchange automatically without complex PLC ladder logic?

Yes. The module supports an "Automatic Data Exchange" function. Once the communication parameters and data addresses are configured in the software, the module handles the polling and data mapping between the PLC registers and the slave devices independently of the CPU scan cycle.

Is this module compatible with building automation systems?

Absolutely. The AH10SCM-5A supports the BACnet Slave function, making it compatible with building management systems (BMS). This allows the AH500 PLC to report status and receive commands from higher-level HVAC and lighting control networks.

What is the benefit of the full isolation design in this module?

The full isolation design prevents ground loops and protects the internal PLC backplane from high-voltage transients that may occur on long-distance RS-485 field wiring. This is critical for maintaining communication stability in environments with heavy electromagnetic interference.


Engineering & Installation Guide

  • Hot-Swapping Protocol: When utilizing the hot-swap feature, ensure the module's locking levers are fully released before extraction. The AH500 backplane will automatically detect the removal; however, ensure that the "Automatic Data Exchange" settings are backed up in the CPU to allow the replacement module to resume operation immediately upon insertion.

  • Termination Resistors: For long-distance RS-485 networks (exceeding 100 meters), ensure that a 120-ohm termination resistor is enabled at both physical ends of the communication line. This prevents signal reflection and ensures data integrity at the maximum 460.8 kbps baud rate.

  • Shielding and Grounding: Use shielded twisted-pair (STP) cables for all RS-422/485 connections. The shield should be grounded at a single point (typically at the PLC cabinet side) to prevent circulating currents while providing effective protection against RFI/EMI.

 

Key Features:

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Czarny
Country of origin
Tajwan

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...