ABB

ABB DI620 3BHT300002R1 S600 I/O Digital Input Module

SKU DI620 3BHT300002R1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: DI620 3BHT300002R1

  • Country of origin:Switzerland

  • Product Type: Digital Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 3.8 cm x 26 cm x 27.1 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ABB DI620 (3BHT300002R1) is a high-performance Digital Input Module designed for integration within the ABB S600 I/O system architecture. This module serves as a critical interface in distributed control systems (DCS), reliably acquiring binary status signals from industrial field devices such as sensors, switches, and limit contacts, and transmitting them to the central controller.

Engineered for demanding industrial environments, the DI620 module ensures high availability and precise signal processing for automation applications. It supports streamlined cabinet layouts and integrates natively into the ABB control ecosystem, reducing engineering time and simplifying maintenance workflows.

Features

  • Native component of the ABB S600 I/O hardware family
  • Designed for reliable acquisition of digital input signals in DCS architectures
  • Robust industrial construction suitable for continuous operation in harsh environments
  • Pluggable terminal block design for fast installation and replacement without rewiring
  • Diagnostic LED indicators for module status and channel-level monitoring

Applications

  • Distributed Control Systems (DCS) for process industries
  • Factory automation and discrete manufacturing lines
  • Power generation and utility distribution plants
  • Oil and gas upstream and downstream facilities
  • Water and wastewater treatment installations

Technical Specifications

Parameter Specification
Manufacturer ABB
Product Type Digital Input Module
Model / Ordering Number DI620 / 3BHT300002R1
Product Family S600 I/O
Country of Origin Sweden
Net Weight 0.5 kg (Approximate)
Mounting Type DIN Rail / Rack Mounting (System specific)
Signaling / Diagnostics Status LEDs for power, error, and channel states

Installation Guidelines

  1. Verify the part number and ordering code (3BHT300002R1) against system documentation prior to installation.
  2. Ensure all power to the S600 I/O rack and associated field wiring is de-energized before handling the module.
  3. Inspect the module and backplane connectors for any signs of physical damage or debris.
  4. Securely mount the DI620 module onto the designated S600 I/O baseplate or DIN rail slot.
  5. Connect the field signal wiring to the terminal blocks according to the specific application wiring diagrams.
  6. Restore power and verify module recognition and channel functionality through the engineering software configuration tools.

FAQ

What system family does the ABB DI620 belong to?

The ABB DI620 (3BHT300002R1) belongs to the ABB S600 I/O product family, designed for use in advanced distributed control systems.

What is the primary function of the DI620 3BHT300002R1 module?

The ABB DI620 3BHT300002R1 functions as a digital input module that acquires discrete binary signals from industrial field devices and relays them to the control system.

Are terminal blocks included with the ABB DI620?

Terminal block availability can vary depending on whether the unit is ordered as a spare part or complete assembly; consult your specific order configuration for details.

How do I verify the operational status of the DI620 module?

The ABB DI620 features integrated diagnostic LED indicators on the front panel that provide real-time visual feedback on module health, communication, and individual channel states.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Switzerland

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.