1 of 1

B&R X20SC2212 X20 System Safe Digital Mixed I/O Module

B&R X20SC2212 X20 System Safe Digital Mixed I/O Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20SC2212

  • Country of origin:United States

  • Product Type: Digital Mixed Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The B&R X20SC2212, part number X20SC2212, is a safety-oriented digital mixed I/O module designed for integration within the X20 system backplane communication architecture to execute fail-safe control logic. The electronic module incorporates 6 safe type A digital inputs paired with 6 dedicated pulse outputs for cross-fault detection monitoring, alongside 2 safe type B1 digital outputs rated at 24 VDC and 0.5 A. Actuation and switching behavior for the safety outputs utilize an Output Signal Switching Device (OSSD) design with a diagnostic test pulse width of less than 500 µs to guarantee rapid response times during safety demands. Power distribution across the internal circuitry runs on a nominal 24 VDC bus with integrated reverse polarity protection to prevent component damage from improper electrical installation.

Hardware Specifications

  • Module Type: Safety-related digital mixed I/O module
  • Input Configuration: 6 safe type A digital inputs
  • Output Configuration: 2 safe type B1 digital outputs, 6 pulse outputs
  • Nominal Voltage: 24 VDC
  • Permissible Voltage Range: 20.4 to 28.8 VDC (24 VDC -15% / +20%)
  • Digital Output Current Rating: 0.5 A per channel
  • OSSD Pulse Width: <500 µs
  • Integrated Protection: Reverse polarity protection
  • Operating Humidity Range: 5 to 95%, non-condensing
  • Storage Humidity Range: 5 to 95%, non-condensing
  • Transport Humidity Range: 5 to 95%, non-condensing
  • Shipping Weight: 2 kg

Engineering Notes

  • Cyclic data exchange across the X20 backplane handles the safety I/O image transmission via the openSAFETY protocol to ensure deterministic communication timings.
  • The 6 pulse outputs emit specific test patterns that feed back into the 6 safe type A digital inputs to continuously verify physical line integrity and diagnose short circuits across channels or to external potential lines.
  • Safe type B1 digital outputs execute internal dual-channel monitoring sequences to detect component failures, ensuring the module transitions to a defined safe state if an unrecoverable fault occurs.
  • The operational power window is strictly limited to 20.4 to 28.8 VDC; any fluctuation outside these parameters causes an undervoltage or overvoltage diagnostic fault register entry, disabling the safety outputs.

Field Guidelines

  • Backplane Communication Shielding: Ensure the X20 bus base components are securely snapped together on the DIN rail to maintain low-impedance grounding across the local backplane communication segments.
  • Cable Routing and Separation: Route safety sensor and actuator wiring cables in separate wire ducts from high-current AC or variable speed drive conductors to minimize electromagnetic interference on the OSSD pulse lines.
  • Shield Grounding: Ground all shielded cables used for remote safety sensors directly at the entry point of the control panel enclosure using a low-impedance grounding rail.
  • Connector Insulation and Termination: Ensure all field wiring connections utilize correct cross-section conductors and crimped wire ferrules to secure consistent contact force within the terminal block layout.

Technical & Procurement FAQ

Question: Is the X20SC2212 safety module hot-swappable within an active X20 I/O chassis segment?

Answer: Yes, the three-part modular design of the X20 system allows the electronic module to be hot-swappable without disconnecting the terminal block wiring or breaking the backplane communication loop of adjacent modules.

Question: What firmware matching requirements apply when replacing a legacy hardware revision of this module?

Answer: Firmware compatibility is managed through the automation software platform, which cross-references the safety configuration checksum to ensure complete functional matching before allowing cyclic data exchange to resume.

Question: What physical contents are included out-of-the-box with the specific part number X20SC2212?

Answer: The package contains the brand new original stock electronic module itself; the matching X20 bus base and X20 front terminal block must be ordered as separate accessories to complete the mechanical installation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Yellow
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...