BECKHOFF

BECKHOFF C9900-P313 Redundant ATX Power Supply

SKU C9900-P313

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: C9900-P313
  • Origin Germany
  • Product Type: Industrial PC Power Supplies
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF C9900-P313 is a high-availability redundant ATX power supply option engineered specifically for 19-inch slide-in Industrial PCs. This system-level power solution is designed to replace the standard single power supply in compatible BECKHOFF hardware, providing hardware-level power redundancy to maximize operational uptime and prevent unscheduled system shutdowns.

Operating with a wide input voltage range of 100 to 240 V AC, the BECKHOFF C9900-P313 delivers a continuous power output rating of 450 W. It is designed for seamless physical and electrical integration within the designated industrial PC chassis, meeting the high electrical safety and stability requirements of modern control and visualization systems.

Features

  • Provides full power supply redundancy for high-availability industrial systems.
  • Delivers up to 450 W of regulated power output.
  • Supports a universal wide-range AC input voltage of 100 to 240 V AC.
  • Direct replacement option for standard factory-installed single ATX power supplies.
  • Designed to maintain complete hardware operation during individual power unit maintenance or power supply line failures.

Applications

  • Integration into high-reliability control environments running critical production or visualization processes.
  • Server-level industrial automation architectures requiring redundant power feeds.
  • Control cabinet setups where continuous 24/7 machine operation is mandatory.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model C9900-P313
Product Type Redundant ATX Power Supply
Compatible IPC Models BECKHOFF C5102, BECKHOFF C5240
Input Voltage Range 100...240 V AC
Output Power 450 W
Hardware Form Factor ATX redundant slide-in configuration

Installation Guidelines

  1. Ensure that the host Industrial PC is fully de-energized and disconnected from all AC power sources before beginning installation or replacement.
  2. Remove the industrial PC casing cover according to the manufacturer manual for your C5102 or C5240 cabinet model.
  3. Carefully disconnect the internal ATX and peripheral power cabling of the existing standard power supply unit.
  4. Unmount and slide the standard power supply out of the chassis bay.
  5. Slide the BECKHOFF C9900-P313 redundant unit into the power supply bay and secure it using the original mounting points.
  6. Reconnect all internal ATX motherboard and peripheral power connections, checking for correct pin alignment and cable clearance.
  7. Reinstall the PC housing cover, connect both redundant AC line inputs, and verify proper system booting and LED status signaling.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF C9900-P313?
The BECKHOFF C9900-P313 is a redundant ATX power supply designed to replace the standard power supply in specific industrial PCs, ensuring continuous operation and preventing downtime by providing electrical redundancy.
Which Industrial PC models are compatible with the BECKHOFF C9900-P313?
The BECKHOFF C9900-P313 is designed specifically for integration with BECKHOFF C5102 and BECKHOFF C5240 19-inch slide-in Industrial PCs.
What are the input voltage and output power ratings of the BECKHOFF C9900-P313?
The BECKHOFF C9900-P313 redundant power supply supports a standard AC input voltage range of 100 to 240 V AC and features an active power output rating of 450 W.
Does the BECKHOFF C9900-P313 slide-in power supply support hot-swapping?
The BECKHOFF C9900-P313 redundant units allow system operation to continue if one module fails, but any physical replacement should always be executed under strict adherence to safety protocols and the host IPC user documentation.
Reviews

C9900-P313

Stock & lead time on request

Call
1 of 1

BECKHOFF C9900-P313 Redundant ATX Power Supply

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-P313

  • Country of origin:Germany

  • Product Type: Industrial PC Power Supplies

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF C9900-P313 is a high-availability redundant ATX power supply option engineered specifically for 19-inch slide-in Industrial PCs. This system-level power solution is designed to replace the standard single power supply in compatible BECKHOFF hardware, providing hardware-level power redundancy to maximize operational uptime and prevent unscheduled system shutdowns.

Operating with a wide input voltage range of 100 to 240 V AC, the BECKHOFF C9900-P313 delivers a continuous power output rating of 450 W. It is designed for seamless physical and electrical integration within the designated industrial PC chassis, meeting the high electrical safety and stability requirements of modern control and visualization systems.

Features

  • Provides full power supply redundancy for high-availability industrial systems.
  • Delivers up to 450 W of regulated power output.
  • Supports a universal wide-range AC input voltage of 100 to 240 V AC.
  • Direct replacement option for standard factory-installed single ATX power supplies.
  • Designed to maintain complete hardware operation during individual power unit maintenance or power supply line failures.

Applications

  • Integration into high-reliability control environments running critical production or visualization processes.
  • Server-level industrial automation architectures requiring redundant power feeds.
  • Control cabinet setups where continuous 24/7 machine operation is mandatory.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model C9900-P313
Product Type Redundant ATX Power Supply
Compatible IPC Models BECKHOFF C5102, BECKHOFF C5240
Input Voltage Range 100...240 V AC
Output Power 450 W
Hardware Form Factor ATX redundant slide-in configuration

Installation Guidelines

  1. Ensure that the host Industrial PC is fully de-energized and disconnected from all AC power sources before beginning installation or replacement.
  2. Remove the industrial PC casing cover according to the manufacturer manual for your C5102 or C5240 cabinet model.
  3. Carefully disconnect the internal ATX and peripheral power cabling of the existing standard power supply unit.
  4. Unmount and slide the standard power supply out of the chassis bay.
  5. Slide the BECKHOFF C9900-P313 redundant unit into the power supply bay and secure it using the original mounting points.
  6. Reconnect all internal ATX motherboard and peripheral power connections, checking for correct pin alignment and cable clearance.
  7. Reinstall the PC housing cover, connect both redundant AC line inputs, and verify proper system booting and LED status signaling.
Loading product navigation…

What is the primary function of the BECKHOFF C9900-P313?

The BECKHOFF C9900-P313 is a redundant ATX power supply designed to replace the standard power supply in specific industrial PCs, ensuring continuous operation and preventing downtime by providing electrical redundancy.

Which Industrial PC models are compatible with the BECKHOFF C9900-P313?

The BECKHOFF C9900-P313 is designed specifically for integration with BECKHOFF C5102 and BECKHOFF C5240 19-inch slide-in Industrial PCs.

What are the input voltage and output power ratings of the BECKHOFF C9900-P313?

The BECKHOFF C9900-P313 redundant power supply supports a standard AC input voltage range of 100 to 240 V AC and features an active power output rating of 450 W.

Does the BECKHOFF C9900-P313 slide-in power supply support hot-swapping?

The BECKHOFF C9900-P313 redundant units allow system operation to continue if one module fails, but any physical replacement should always be executed under strict adherence to safety protocols and the host IPC user documentation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...