BECKHOFF

Beckhoff EL4112-0010 EtherCAT Terminal 2-Channel Analog Output Module

SKU EL4112-0010

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EL4112-0010

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for precision industrial control loops, the EL4112-0010 analog output terminal generates standard electrical current signals in the range of -10 to +10 mA. This analog output terminal processes process data from the automation device with a high resolution of 16 bits (including sign) and transmits it with galvanic isolation directly to the field level. It features integrated Distributed Clocks (DC) support, allowing for highly synchronized, microsecond-level updates across EtherCAT networks.

The system features a 3-wire, single-ended connection technology, making it compatible with a wide array of industrial actuators, control valves, and system drives. With parameterized watchdog functionality and customizable user synchronization, this module delivers stable performance and safe-state fallback options for critical machinery systems.

Features

  • Provides two independent analog output channels with a current range of -10 to +10 mA.
  • Delivers high-precision digital-to-analog conversion at 16-bit resolution (including sign).
  • Supports EtherCAT Distributed Clocks (DC) with synchronization precision under 1 microsecond.
  • Includes short-circuit-proof outputs compatible with loads up to 500 Ohm.
  • Features integrated parameterizable watchdog state and user-activatable synchronization.
  • Constructed with a compact, rugged housing requiring only 12 mm of DIN rail width.

Applications

  • Closed-loop hydraulic and pneumatic valve positioning
  • Variable speed motor drive control systems
  • Distributed industrial process automation and telemetry
  • Power generation and turbine control auxiliary systems

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EL4112-0010
Number of Outputs 2
Signal Current -10 to +10 mA
Resolution 16 bit (incl. sign)
Connection Technology 3-wire, single-ended
Power Supply 24 V DC via power contacts
Current Consumption E-bus typ. 160 mA
Current Consumption Power Contacts typ. 15 mA + load
Process Image Bit Width 2 x 16 bit AO output
Maximum Output Rate 15 ksps
Load < 500 Ohm (short-circuit proof)
Measuring / Output Error < +-0.1% (relative to end value)
Electrical Isolation 500 V (E-bus / signal voltage)
Distributed Clocks Yes (precision << 1 microsecond)
Housing Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight approx. 65 g
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20

Connections and Interfaces

Connection Type Conductor Cross-Section AWG Range Stripping Length
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
With Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16 8 to 9 mm

Installation Guidelines

  • Mount vertically onto standard 35 mm DIN rails conforming to EN 60715.
  • Ensure lock connection is engaged correctly during side-by-side terminal configuration via the integrated double slot-and-key system.
  • Use a standard screwdriver to actuate the spring-clamp terminals when routing field wiring.
  • Avoid installing in environments exceeding 95% non-condensing relative humidity.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

FAQ

What is the primary function of the Beckhoff EL4112-0010?

The Beckhoff EL4112-0010 is a 2-channel analog output terminal designed to output precise current signals ranging from -10 to +10 mA with 16-bit resolution.

Does the EL4112-0010 support synchronized EtherCAT operations?

Yes, it supports EtherCAT Distributed Clocks (DC), enabling highly synchronized output updates with a system precision of under 1 microsecond.

What is the maximum current load for the power contacts on this terminal?

The maximum current load capability of the power contacts on the EL4112-0010 is 10 A.

What is the protection rating and mounting method for this device?

The module features an IP20 protection rating and is designed for direct mounting onto standard 35 mm DIN rails (EN 60715).

Is the EL4112-0010 certified for hazardous industrial locations?

Yes, the terminal is ATEX-certified with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.