BECKHOFF

BECKHOFF EPP3632-0001 EtherCAT P Box Condition Monitoring Interface

SKU EPP3632-0001

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EPP3632-0001

  • Country of origin:Germany

  • Product Type: EtherCAT P Box Modules

  • Payment: T/T, Western Union

  • Weight: 165g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF EPP3632-0001 is a highly precise 2-channel analog input interface designed for condition monitoring and vibration analysis. Built in the compact, ruggedized EtherCAT P Box form factor, this module enables direct, decentralized acquisition of signals from IEPE (Integrated Electronics Piezo-Electric) constant-current sensors, such as high-frequency accelerometers and microphones.

By utilizing EtherCAT P technology, the BECKHOFF EPP3632-0001 combines high-speed communication and power transmission (both Us control voltage and Up peripheral voltage) into a single, standardized M8 connection. This decentralized design eliminates the need for long, noise-sensitive analog sensor cables by converting signals directly at the measuring point, significantly improving signal quality and system architecture flexibility.

Features

  • Two-channel analog input specifically optimized for IEPE constant-current sensors.
  • Individually configurable sensor excitation current (2 mA, 4 mA, or 8 mA) for both channels.
  • High-resolution 16-bit analog-to-digital conversion with a fast sampling rate of up to 50 ksamples/s (20 microsecond conversion time).
  • Parameterizable 5th-order analog low-pass filter (up to 25 kHz) and high-pass filtering for tailored vibration analysis.
  • Distributed Clocks (DC) support for microsecond-level synchronization across the industrial network.
  • Integrated sensor state diagnostics via continuous bias voltage monitoring.
  • Rugged IP65, IP66, and IP67 industrial housing suitable for direct machine mounting without an enclosure.

Applications

  • Decentralized vibration and structural health monitoring of rotating equipment.
  • Real-time bearing and gearbox diagnostics in harsh production environments.
  • Acoustic emission analysis and machine noise monitoring.
  • Direct-on-machine field installation to minimize analog cabling runs.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model EPP3632-0001
Product Type EtherCAT P Box (Condition Monitoring)

Signal and I/O

Number of Channels 2 analog inputs
Signal Type IEPE (constant current supply and modulated AC voltage)
Resolution 16 bit (including sign)
Measuring Range Default: ±5 V (up to 25 kHz) / ±250 mV (up to 10 Hz)
Conversion Time 20 microseconds (max. 50 ksamples/s)
Measurement Error Less than ±0.5 % (DC; relative to full scale value)
Input Filter Parameterizable 5th-order low-pass filter (up to 25 kHz); typ. 0.05 Hz high-pass filter
Sensor Supply (I_EXCITE) Typ. 2, 4, or 8 mA (separately configurable per channel)
Sensor State Monitoring Yes, through continuous bias voltage monitoring (wire breakage detection)

Electrical and Communication

Protocol EtherCAT P
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Distributed Clocks Yes
Nominal Voltage 24 V DC (-15 % / +20 % from control voltage Us)
Electrical Isolation 500 V

Mechanical and Environmental

Connection Method (Sensors) M8, 4-pin, screw type, shielded
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Weight Approx. 165 g

Connections / Interfaces

Interface Function
EtherCAT P (P-coded M8) Combined communication and power input / output loop-through
Input Channels (M8 4-pin) Shielded connections for IEPE sensor signals and constant current excitation

Installation Guidelines

  1. Ensure the entire EtherCAT P segment is de-energized before mounting or making connections.
  2. Secure the box to a clean, flat surface using standard M3 screws through the integrated mounting eyelets.
  3. Use only shielded, P-coded M8 cabling for the EtherCAT P bus interface to guarantee reliable data transmission and power delivery.
  4. Connect the IEPE sensors using shielded M8, 4-pin screw-type connectors, ensuring the shields are correctly terminated to minimize electromagnetic noise.
  5. Verify that all unused M8 ports are sealed with appropriate protective caps to maintain the IP67 environmental rating.

Configuration Guidelines

Configuration of the BECKHOFF EPP3632-0001 is performed through the TwinCAT System Manager. Users must configure the appropriate sensor supply excitation current (2 mA, 4 mA, or 8 mA) and the analog filtering parameters within the CoE (CANopen over EtherCAT) settings online to match the specific electrical specifications of the connected IEPE sensors.

FAQ

What is the primary function of the BECKHOFF EPP3632-0001?

The BECKHOFF EPP3632-0001 is a 2-channel analog input EtherCAT P Box module designed for condition monitoring, vibration analysis, and high-frequency acoustic measurements using IEPE constant-current sensors.

How is the BECKHOFF EPP3632-0001 powered and connected?

The BECKHOFF EPP3632-0001 utilizes EtherCAT P, which integrates high-speed Ethernet communication and 24 V DC power (control and peripheral supply) into a single, shielded, P-coded M8 cable interface.

Does the BECKHOFF EPP3632-0001 require a protective control cabinet?

No, the BECKHOFF EPP3632-0001 features a robust design with IP65, IP66, and IP67 protection ratings, enabling direct installation onto machinery in harsh environments without an electrical cabinet.

What excitation currents does the BECKHOFF EPP3632-0001 provide for IEPE sensors?

The BECKHOFF EPP3632-0001 supports adjustable sensor excitation currents of 2 mA, 4 mA, or 8 mA, which can be configured individually for each of the two channels via TwinCAT.

How does the BECKHOFF EPP3632-0001 detect wire breakages in connected sensors?

The BECKHOFF EPP3632-0001 monitors the sensor bias voltage to perform continuous diagnostic checks, allowing it to detect wire breakages or sensor fault states in real time.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.