BECKHOFF

BECKHOFF IP6002-B810 Fieldbus Box

SKU IP6002-B810

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP6002-B810
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP6002-B810 is a rugged, decentralized Fieldbus Box designed for direct machine installation without a protective control cabinet. Utilizing an open, documented serial transmission protocol, this module facilitates direct communication with digital and analog peripheral signals. It acts as an integration point for distributed machine installations, providing reliable data handling and high environmental protection.

The device features an integrated RS485 communication interface routed through a robust 5-pin, B-coded M12 connector. Parameterization, diagnosis, and configuration of the module are handled through the standard BECKHOFF KS2000 software tool, allowing simple integration into existing setups. To streamline installation, the module includes standardized M8 power connections, providing a secure feed and an integrated downstream loop for daisy-chaining power to adjacent modules.

Features

  • Implements an open, fully documented serial communication protocol for wide system compatibility.
  • Features a single 5-pin, B-coded M12 socket for the primary bus interface connection.
  • Compatible with the BECKHOFF KS2000 software tool for straightforward software configuration.
  • Equipped with M8 4-pin electrical interfaces for both input power feed and downstream distribution.
  • Provides internal electrical isolation between the control voltage and the fieldbus network.
  • Boasts an IP65, IP66, and IP67-rated enclosure, allowing variable installation positions directly on machinery.

Applications

  • Control-cabinet-free distributed industrial automation and data collection.
  • Decentralized signal routing on packaging systems, material handling machinery, and conveyor networks.
  • Harsh operating environments requiring direct-mount, high-protection class fieldbus nodes.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP6002-B810
Extension Modules None
Configuration Possibility Via KS2000 software

Electrical and Signals

Control Voltage 24 V DC (-15% / +20%)
Load Voltage According to I/O type
Digital Peripheral Signals According to I/O type
Analog Peripheral Signals According to I/O type
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: Yes; Control voltage/I/O: According to I/O type

Interfaces and Connections

Bus Interface 1 x M12 socket, 5-pin, B-coded
Power Supply Feed 1 x M8 male connector, 4-pin
Power Downstream Connection 1 x M8 female connector, 4-pin

Mechanical and Environmental

Dimensions Approx. 210 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL

Installation Guidelines

  1. Ensure that the power supply to the entire automation system is fully de-energized before mounting.
  2. Mount the module securely using the designated integrated mounting holes on the machine frame in a variable, application-appropriate position.
  3. Connect the fieldbus communication cable to the B-coded 5-pin M12 socket, ensuring the plug is properly seated to preserve the ingress protection rating.
  4. Provide the 24 V DC control voltage to the M8 4-pin male feed port. If routing power to subsequent modules, connect the M8 female downstream port to the next unit.
  5. Perform configuration and commissioning parameters within the KS2000 environment.
  6. Energize the system and verify standard operational diagnostics via the system status indicators.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What protocol does the BECKHOFF IP6002-B810 use?
The BECKHOFF IP6002-B810 Fieldbus Box communicates using an open, fully documented serial interface protocol via its integrated M12, B-coded, 5-pin port.
How is the BECKHOFF IP6002-B810 Fieldbus Box configured?
The BECKHOFF IP6002-B810 is configured and parameterized using the official BECKHOFF KS2000 software environment.
What are the power connection interfaces of the BECKHOFF IP6002-B810?
The BECKHOFF IP6002-B810 features two 4-pin M8 connections: one male socket for incoming power feed and one female socket for downstream power loops.
Can the BECKHOFF IP6002-B810 handle harsh environments?
Yes, the BECKHOFF IP6002-B810 features an IP65/66/67 ingress protection rating, making it suitable for direct control-cabinet-free installation on machinery within dusty or damp environments.
Reviews

IP6002-B810

Stock & lead time on request

Call
1 of 1

BECKHOFF IP6002-B810 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP6002-B810

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF IP6002-B810 is a rugged, decentralized Fieldbus Box designed for direct machine installation without a protective control cabinet. Utilizing an open, documented serial transmission protocol, this module facilitates direct communication with digital and analog peripheral signals. It acts as an integration point for distributed machine installations, providing reliable data handling and high environmental protection.

The device features an integrated RS485 communication interface routed through a robust 5-pin, B-coded M12 connector. Parameterization, diagnosis, and configuration of the module are handled through the standard BECKHOFF KS2000 software tool, allowing simple integration into existing setups. To streamline installation, the module includes standardized M8 power connections, providing a secure feed and an integrated downstream loop for daisy-chaining power to adjacent modules.

Features

  • Implements an open, fully documented serial communication protocol for wide system compatibility.
  • Features a single 5-pin, B-coded M12 socket for the primary bus interface connection.
  • Compatible with the BECKHOFF KS2000 software tool for straightforward software configuration.
  • Equipped with M8 4-pin electrical interfaces for both input power feed and downstream distribution.
  • Provides internal electrical isolation between the control voltage and the fieldbus network.
  • Boasts an IP65, IP66, and IP67-rated enclosure, allowing variable installation positions directly on machinery.

Applications

  • Control-cabinet-free distributed industrial automation and data collection.
  • Decentralized signal routing on packaging systems, material handling machinery, and conveyor networks.
  • Harsh operating environments requiring direct-mount, high-protection class fieldbus nodes.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP6002-B810
Extension Modules None
Configuration Possibility Via KS2000 software

Electrical and Signals

Control Voltage 24 V DC (-15% / +20%)
Load Voltage According to I/O type
Digital Peripheral Signals According to I/O type
Analog Peripheral Signals According to I/O type
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: Yes; Control voltage/I/O: According to I/O type

Interfaces and Connections

Bus Interface 1 x M12 socket, 5-pin, B-coded
Power Supply Feed 1 x M8 male connector, 4-pin
Power Downstream Connection 1 x M8 female connector, 4-pin

Mechanical and Environmental

Dimensions Approx. 210 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL

Installation Guidelines

  1. Ensure that the power supply to the entire automation system is fully de-energized before mounting.
  2. Mount the module securely using the designated integrated mounting holes on the machine frame in a variable, application-appropriate position.
  3. Connect the fieldbus communication cable to the B-coded 5-pin M12 socket, ensuring the plug is properly seated to preserve the ingress protection rating.
  4. Provide the 24 V DC control voltage to the M8 4-pin male feed port. If routing power to subsequent modules, connect the M8 female downstream port to the next unit.
  5. Perform configuration and commissioning parameters within the KS2000 environment.
  6. Energize the system and verify standard operational diagnostics via the system status indicators.
Loading product navigation…
Key Features:

What protocol does the BECKHOFF IP6002-B810 use?

The BECKHOFF IP6002-B810 Fieldbus Box communicates using an open, fully documented serial interface protocol via its integrated M12, B-coded, 5-pin port.

How is the BECKHOFF IP6002-B810 Fieldbus Box configured?

The BECKHOFF IP6002-B810 is configured and parameterized using the official BECKHOFF KS2000 software environment.

What are the power connection interfaces of the BECKHOFF IP6002-B810?

The BECKHOFF IP6002-B810 features two 4-pin M8 connections: one male socket for incoming power feed and one female socket for downstream power loops.

Can the BECKHOFF IP6002-B810 handle harsh environments?

Yes, the BECKHOFF IP6002-B810 features an IP65/66/67 ingress protection rating, making it suitable for direct control-cabinet-free installation on machinery within dusty or damp environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...