Technical Summary

The Bently Nevada 106765-04 is a 4-meter interconnect cable engineered for transmitting dynamic eddy current sensor signals within the 3300 Proximity Transducer System. It establishes a dedicated electrical pathway linking the Proximitor Sensor to the 3300 rack monitor. The hardware minimizes signal attenuation and impedance mismatch, preventing RF reflections and phase shifts across the 24.3 mV/um or 7.87 V/mm scale factor. This shielding architecture blocks electromagnetic interference (EMI) to isolate critical vibration frequencies, eliminating reading drift and preventing false machine trips during high-frequency rotor dynamics tracking.

Suffix Breakdown

  • 106765 - Base model identifier for high-performance coaxial interconnect cables optimized for Bently Nevada proximity systems.
  • -04 - Defines the specific physical length configuration representing 4.0 meters (13.1 feet) of overall cable length.

Technical Specifications

Parameter Specification Value
Model 106765-04
Brand Bently Nevada
Origin United States
Cable Type Coaxial, shielded
Physical Length 4.0 meters (13.1 feet)
System Compatibility 3300 Proximity Transducer System
Net Weight 0.18 kg
Dimensions 4.0 meters (length) x 3.2 mm (diameter)
Operating Temperature -51 deg C to +177 deg C
Power Consumption Passive device (0.0 mW)
Impedance 75.0 ohms nominal
Connector Material Gold-plated brass (ClickLoc style)

Engineering FAQs

Q: Can the 106765-04 cable be modified or spliced in the field if the length is excessive?

A: Splicing or cutting this coaxial cable alters the total system capacitance and electrical length, which destroys the calibrated 7.87 V/mm (200 mV/mil) scale factor. Excess length must be looped and secured, not removed.

Q: Is the 106765-04 directly compatible with the newer 3300 XL series Proximitor sensors?

A: It interfaces physically with 3300 XL hardware, but using the non-XL 106765 cable with an XL Proximitor limits system performance to legacy 3300 standards and may introduce minor linearity discrepancies. Use 3300 XL series extensions for full XL specs.

Q: What occurs if the coaxial connectors encounter moisture or oil contamination inside a conduit?

A: Liquid ingress causes cross-talk or insulation breakdown, shifting the gap voltage reading toward zero VDC and generating false probe fault alerts. Seal connections with silicone tape or fluid-tight terminal boxes.

Field Guidelines

  • Mechanical Installation: Maintain a minimum bend radius of 25.4 mm during installation. Avoid sharp bends or kinks that displace the internal dielectric layer and degrade signal propagation.
  • Shield Grounding Circuitry: Terminate the outer shield braid strictly at the monitor rack chassis ground. Leave the field sensor end floating inside an isolated terminal block to prevent ground loops that superimpose 50/60 Hz noise onto the vibration signal.
  • Connector Torque: Hand-tighten the coaxial connectors until the internal lock clicks. Apply a single drop of non-conductive thread-locking compound if operating under extreme structural vibration profiles; do not use pliers.
  • Gap Voltage Verification: Post-installation, verify the static gap voltage measures between -9.0 VDC and -11.0 VDC (nominal target -10.0 VDC) using a digital multimeter at the terminal block to confirm correct electrical length match.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 106765-04 Interconnect Cable

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.