Description

The 106M1081-01 Universal AC Power Input Module (PIM) is a rear-mount power interface module engineered for the Bently Nevada 3500/15 AC and DC Power Supplies system. Positioned in the rear slot directly behind its associated front-facing power supply module, the 106M1081-01 receives line AC power and routes it to the 106M1079-01 Universal AC Power Supply module. It converts incoming AC line voltage into acceptable operating levels for the 3500 Series Machinery Protection System rack. Note that the 106M1081-01 Universal AC PIM is not compatible with legacy 3500 AC power supplies or legacy AC power input modules.

Features

  • Accepts nominal 110 to 220 Vac input with wide operating limits (85 to 264 Vac rms for non-hazardous areas, 85 to 250 Vac rms for hazardous areas).
  • Dedicated half-height module design installed directly behind the matching front-facing power supply module.
  • Operates in combination with the 3500/15 Universal AC Power Supply module (106M1079-01).
  • Integrated over-voltage protection via fuse located on the power input module.
  • Built-in protection ensuring under-voltage conditions cause no damage to the module or power supply.
  • Supports seamless module insertion and removal without interrupting rack operation in dual-redundant power configurations.

Applications

  • AC-powered 3500 Series Machinery Protection System racks.
  • Turbomachinery vibration, axial position, and condition monitoring systems.
  • Continuous critical machinery protection in power generation, oil and gas, and petrochemical facilities.

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada / Baker Hughes
Model Part Number 106M1081-01
Module Type Universal AC Power Input Module (PIM)
System Compatibility 3500/15 Power Supply System
Nominal Input Voltage 110 to 220 Vac
Input Voltage Range (Non-hazardous) 85 to 264 Vac rms
Input Voltage Range (Hazardous) 85 to 250 Vac rms
Peak Input Voltage 120 to 373 Vac pk
Input Frequency 47 to 63 Hz
Full Rack Current Draw 2.8 A rms (maximum)
Over-Voltage Protection Fuse opens on the PIM
Under-Voltage Protection Under-voltage does not harm supply or PIM
Replacement Fuse Part Number 120M3877 (Fast blow rated at 5A/500 Vac, Size 6.3 x 32 mm)
Replacement Connector Part Number 118M0915-01
Dimensions (H x W x D) 120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)
Weight 0.34 kg (0.75 lb)
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, non-condensing

Installation Guidelines

  • Rack Mounting Location: Mount the module in the special half-height rear slot located directly behind the associated 3500/15 Universal AC Power Supply module.
  • Redundant Operations: In dual-supply rack setups, inserting or removing either power supply module will not interrupt rack operation as long as a secondary supply is active.
  • Voltage and Wiring Security: Ensure AC supply lines adhere to specified input voltage limits (85 to 264 Vac rms non-hazardous / 85 to 250 Vac rms hazardous) and frequency range (47 to 63 Hz).
  • Fuse Maintenance: If an over-voltage condition causes the module fuse to open, replace it using verified replacement fuse part number 120M3877.
  • Compatibility Check: Verify that the front power supply module is the matching 106M1079-01 Universal AC Power Supply, as legacy AC modules are incompatible.

Compliance and Certifications

  • FCC: Part 15 Class A
  • EMC Directives: European Community Directive 2014/30/EU; EN 61000-6-2, EN 61000-6-4
  • Electrical Safety: European Community Directive 2014/35/EU; EN 61010-1
  • RoHS: European Community Directive 2011/65/EU
  • Maritime Approvals: DNV GL rules for classification; ABS Rules for Condition of Classification
  • Hazardous Area Approvals: Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)
  • ATEX / IECEx: Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)

FAQ

What happens when an over-voltage occurs on the universal AC power input module?

An over-voltage condition causes the internal fuse on the power input module to open, protecting the rack electronics.

Is the universal AC power input module compatible with legacy 3500 AC power supplies?

No, the Universal AC Power Supply and Power Input Module are not compatible with the legacy High Voltage AC or Low Voltage AC units.

Can the module be replaced without interrupting system operation?

Yes, in a rack equipped with dual redundant power supplies, removing or inserting a power supply module does not disrupt overall rack operation.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 106M1081-01 3500/15 Universal AC Power Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.