Bently Nevada

Bently Nevada 133819-01 3500/60 RTD/TC Non-Isolated I/O Module

SKU 133819-01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 133819-01

  • Country of origin:United States

  • Product Type: Temperature I/O Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 241.3 mm x 24.4 mm x 99.1 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Bently Nevada 133819-01 is a rear-mount 3500/60 RTD/TC non-isolated I/O module equipped with internal terminations designed for the 3500 Series Machinery Protection System. It provides terminal connections for up to six Resistance Temperature Detector (RTD) or Thermocouple (TC) signals, transferring conditioned temperature data to the main 3500/60 monitor module. The 133819-01 accepts mixed RTD and TC inputs across its six channels and utilizes direct internal screw/header terminal blocks for field transducer wiring without requiring external termination blocks.

Features

  • Accepts up to 6 RTD or Thermocouple transducer inputs with non-isolated signal conditioning.
  • Integrated internal terminal blocks for direct field wiring connection.
  • Supports mixed configuration of RTD and TC sensor types across channels via rack configuration software.
  • Mounts directly into a single full-height rear slot of the 3500 rack system.

Applications

  • Machinery temperature monitoring for industrial rotating equipment
  • Bearing and winding temperature protection in power generation and petrochemical facilities
  • Continuous asset health monitoring integrated into Bently Nevada 3500 Series TSI systems

Ordering Information

Part / Option Description
3500/60-01-00 3500/60 RTD/TC Non-Isolated I/O Module, Internal Terminations, No Approvals
3500/60-01-01 3500/60 RTD/TC Non-Isolated I/O Module, Internal Terminations, CSA/NRTL/C Approval
3500/60-01-02 3500/60 RTD/TC Non-Isolated I/O Module, Internal Terminations, ATEX/IECEx/CSA Approval
133819-01 Spare 3500/60 RTD/TC Non-Isolated I/O Module with Internal Terminations

Technical Specifications

Category Parameter Specification
Input Capabilities Transducer Signal Inputs Accepts 1 to 6 RTD or TC signals
  Supported RTD Types 100 ohm 3-wire/4-wire Pt (alpha = 0.00385 or 0.00392), 120 ohm 3-wire/4-wire Ni, 10 ohm 3-wire/4-wire Cu
  Supported TC Types Type E, Type J, Type K, Type T
  Input Impedance 10 Mohm for each lead input
Physical Rack Space Requirement 1 full-height rear slot
  Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
  Weight 0.45 kg (1.0 lb)
Environmental Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
  Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
  Relative Humidity 95% non-condensing

Connections/Interfaces

Connector Pin / Header Function
Internal Terminal Strip Signal input connections for RTD/TC Channels 1 through 6
Connector Header 00580442 9-position internal termination green header
Connector Header 00580443 12-position internal termination green header
Connector Header 00580444 15-position internal termination green header

Installation Guidelines

  • Install the module into the rear slot of the 3500 rack directly aligned behind the corresponding 3500/60 main monitor module.
  • Secure the card in place by tightening the top and bottom captive mounting screws.
  • Wire field RTD or thermocouple sensor leads directly to the green internal terminal connectors using appropriate field wiring guidelines.
  • Ensure proper cable shielding to minimize electromagnetic interference on low-voltage thermocouple and resistance measurement circuits.

Compliance and Certifications

  • EMC Directive: 2014/30/EU (EN 61000-6-2, EN 61000-6-4)
  • Low Voltage Directive: 2014/35/EU (EN 61010-1)
  • RoHS Directive: 2011/65/EU
  • Cyber Security: Designed to meet IEC 62443
  • Functional Safety: SIL 2 rated
  • Maritime Approvals: DNV GL rules, ABS rules
  • Hazardous Area Approvals: CSA/NRTL/C (Class I, Div 2 / Zone 2), ATEX/IECEx (Ex nA nC ic IIC T4 Gc / Ex ec nC ic IIC T4 Gc)

FAQ

How many temperature transducer channels does the module support?

The module supports up to six RTD or thermocouple temperature input channels.

What is the operating temperature range of this I/O module?

The operating temperature range is from -30 degC to +65 degC.

Does this I/O module require an external termination block?

No, this module features internal terminations allowing field wiring to connect directly to integrated terminal blocks.

What rack space requirement is needed for installation?

The module requires one full-height rear slot in a standard 3500 system rack.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 133819-01 3500/60 RTD/TC Non-Isolated I/O Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...