Commissioning IO-Link From Master Ports to IODD Data
Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.
Manufacturer: Bently Nevada
Product No.: 22810-00-05-05-00
Country of origin:United States
Product Type: 5 mm and 8 mm Standard Mount Probe
Barcode: 8537101190
Payment: T/T, Western Union
Weight: 590g
Dimensions: 1.8cm x 1.6cm x 123cm
Shipping port: Xiamen
Warranty: 12 months
The 22810-00-05-05-00 is an 8 mm Standard Mount Proximity Probe from the Bently Nevada 7200 Series. This configuration features a 3/8-24 UNF threaded body with 0.0 in (0.0 mm) of unthreaded length (Option 00) and a 0.5 in (12.7 mm) case length (Option 05). It is equipped with a 0.5 m integral coaxial cable (Option 05) and is supplied without a connector (Option 00), designed for direct terminal connection in 7200 transducer systems.
As part of the 7200 Series, this eddy-current transducer system provides non-contacting shaft position and vibration measurements. It is constructed of polyphenylene sulfide (PPS), a high-performance plastic capable of withstanding industrial environments including water and lube oil. The probe is compatible with 7200 Series Proximitors and extension cables, facilitating radial vibration, axial thrust position, and eccentricity measurements on rotating machinery such as turbines, compressors, and pumps.
| Option | Code on This SKU | Description |
|---|---|---|
| Orderable Part Number | 22810-00-05-05-00 | 7200 8 mm Standard Mount Probe |
| A - Unthreaded Length | 00 | 0.0 in (0.0 mm) |
| B - Case Length | 05 | 0.5 in (12.7 mm) |
| C - Total Cable Length | 05 | 0.5 m (20 in) integral cable |
| D - Connector Option | 00 | Without connector |
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Model | 22810 |
| Probe Diameter | 8 mm |
| Thread | 3/8-24 UNF-2A |
| Material | Polyphenylene sulfide (PPS) |
| Calibrated Range | 80 mils (2.0 mm) |
| Scale Factor | 200 mV/mil (7.87 V/mm) +/- 4% |
| Frequency Response | 0 Hz to 10 kHz |
| Operating Temperature | -34 degC to +177 degC (-30 degF to +350 degF) |
| Linearity | Within 0.8 mils (0.02 mm) of 200 mV/mil straight line |
| Humidity | To 95%, noncondensing |
Ensure the probe is installed with adequate clearance from the observed target to maintain the 80 mils (2.0 mm) linear range. When routing the integral 0.5 m coaxial cable, avoid sharp bends and maintain separation from high-voltage AC power lines to prevent signal interference. Ensure all connections are secure and protected from physical damage. When used in hazardous locations, verify that the installation complies with local safety standards and the specific approvals (CSA, BASEEFA, FM) for the 7200 system.
The 7200 series transducers are designed to comply with API 670 requirements for vibration monitoring systems. Consult the Bently Nevada hazardous location datasheet for specific CSA, FM, and BASEEFA certification details applicable to the 22810 series.
Global Express Shipping
Returns & Warranty



Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|