Option 03 (30 mm unthreaded length), Option 10 (100 mm case length), and Option 11 (ClickLoc connector with protector, FluidLoc cable) specify this metric 3300 XL 8 mm proximity probe configuration — 330103-03-10-10-11-00.
This metric configuration features an unarmored cable design with M10 x 1 threads, distinguishing it from standard-threaded (3/8-24 UNF) probe configurations like the 330101 or armored options like the 330104. The integration of FluidLoc cable technology prevents oil or other process fluids from leaking through the cable interior, making it well-suited for applications where pressure differentials or fluid containment are critical, while the connector protector adds environmental protection at the probe-to-extension cable junction.
| Option | Code on This SKU | Description |
|---|---|---|
| Orderable Part Number | 330103-03-10-10-11-00 | 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor |
| A - Unthreaded Length | 03 | 30 mm unthreaded length |
| B - Overall Case Length | 10 | 100 mm case length |
| C - Total Length | 10 | 1.0 meter (3.3 feet) total length |
| D - Connector/Cable Option | 11 | Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable |
| E - Agency Approval Option | 00 | Not required |
| Manufacturer | Bently Nevada (Baker Hughes) |
| Part Number/Model | 330103-03-10-10-11-00 |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Thread Size | M10 x 1 |
| Unthreaded Length | 30 mm |
| Case Length | 100 mm |
| Total Cable Length | 1.0 meter (3.3 feet) |
| Cable Type | 75 ohm triaxial fluoroethylene propylene (FEP) insulated, FluidLoc style |
| Connector Type | Miniature coaxial ClickLoc |
| Connector Protector | Pre-installed fluorosilicone protector |
| Calibration Target | AISI 4140 steel |
| Temperature Range | -52 degC to +177 degC (-62 degF to +350 degF) operating/storage |
| Pressure Seal Limit | Seals differential pressure between tip and case with Viton O-ring |
| Recommended Torque | 7.5 N-m (66 in-lbf) standard, 22.6 N-m (200 in-lbf) maximum |
| Tensile Strength Limit | 330 N (75 lbf) probe case to lead |
| Dimensions | 10 mm x 10 mm x 100 mm (H x W x D) |
| Weight | 0.32 kg |
| Connection Type | Description |
|---|---|
| Miniature male coaxial ClickLoc | Gold-plated brass/beryllium copper connector, finger-tight click interface |
| Connector Protector | Pre-installed fluorosilicone protector over the coaxial connection |
Maintain standard thread engagement limits for metric M10 x 1 threads, keeping engagement to 15 mm or less. Tighten the probe case using M10 wrench flats to the recommended 7.5 N-m torque. Inspect and clean miniature coaxial ClickLoc connector faces before connecting. Secure them finger-tight until the lock clicks. Always ensure the minimum cable bend radius of 25.4 mm (1.0 inch) is observed during routing to prevent insulation or shielding fatigue.
Compliance and standards achieved by standard 3300 XL transducer systems include standard European Union EMC Directive (2014/30/EU), RoHS Directive (2011/65/EU), and Functional Safety certification up to SIL 2 (HFT = 0) and SIL 3 (HFT = 1).
Global Express Shipping
Returns & Warranty



Option 03 (30 mm unthreaded length), Option 10 (100 mm case length), and Option 11 (ClickLoc connector with protector, FluidLoc cable) specify this metric 3300 XL 8 mm proximity probe configuration — 330103-03-10-10-11-00.
This metric configuration features an unarmored cable design with M10 x 1 threads, distinguishing it from standard-threaded (3/8-24 UNF) probe configurations like the 330101 or armored options like the 330104. The integration of FluidLoc cable technology prevents oil or other process fluids from leaking through the cable interior, making it well-suited for applications where pressure differentials or fluid containment are critical, while the connector protector adds environmental protection at the probe-to-extension cable junction.
| Option | Code on This SKU | Description |
|---|---|---|
| Orderable Part Number | 330103-03-10-10-11-00 | 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor |
| A - Unthreaded Length | 03 | 30 mm unthreaded length |
| B - Overall Case Length | 10 | 100 mm case length |
| C - Total Length | 10 | 1.0 meter (3.3 feet) total length |
| D - Connector/Cable Option | 11 | Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable |
| E - Agency Approval Option | 00 | Not required |
| Manufacturer | Bently Nevada (Baker Hughes) |
| Part Number/Model | 330103-03-10-10-11-00 |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Thread Size | M10 x 1 |
| Unthreaded Length | 30 mm |
| Case Length | 100 mm |
| Total Cable Length | 1.0 meter (3.3 feet) |
| Cable Type | 75 ohm triaxial fluoroethylene propylene (FEP) insulated, FluidLoc style |
| Connector Type | Miniature coaxial ClickLoc |
| Connector Protector | Pre-installed fluorosilicone protector |
| Calibration Target | AISI 4140 steel |
| Temperature Range | -52 degC to +177 degC (-62 degF to +350 degF) operating/storage |
| Pressure Seal Limit | Seals differential pressure between tip and case with Viton O-ring |
| Recommended Torque | 7.5 N-m (66 in-lbf) standard, 22.6 N-m (200 in-lbf) maximum |
| Tensile Strength Limit | 330 N (75 lbf) probe case to lead |
| Dimensions | 10 mm x 10 mm x 100 mm (H x W x D) |
| Weight | 0.32 kg |
| Connection Type | Description |
|---|---|
| Miniature male coaxial ClickLoc | Gold-plated brass/beryllium copper connector, finger-tight click interface |
| Connector Protector | Pre-installed fluorosilicone protector over the coaxial connection |
Maintain standard thread engagement limits for metric M10 x 1 threads, keeping engagement to 15 mm or less. Tighten the probe case using M10 wrench flats to the recommended 7.5 N-m torque. Inspect and clean miniature coaxial ClickLoc connector faces before connecting. Secure them finger-tight until the lock clicks. Always ensure the minimum cable bend radius of 25.4 mm (1.0 inch) is observed during routing to prevent insulation or shielding fatigue.
Compliance and standards achieved by standard 3300 XL transducer systems include standard European Union EMC Directive (2014/30/EU), RoHS Directive (2011/65/EU), and Functional Safety certification up to SIL 2 (HFT = 0) and SIL 3 (HFT = 1).
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|