Bently Nevada

Bently Nevada 3500/20 125744-02 Rack Interface Module

SKU 3500/20 125744-02

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 3500/20 125744-02

  • Country of origin:United States

  • Product Type: Rack Interface Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 910g

  • Dimensions: 241.3 mm x 24.4 mm x 241.8 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Bently Nevada 125744-02 is a full-height Standard Rack Interface Module (RIM) that serves as the primary data and configuration link to the 3500 Series Machinery Protection System. This module supports a specialized proprietary communication protocol designed to safely configure monitoring chassis hardware and retrieve non-critical diagnostic machinery information for host software packages. It must be placed in slot 1 of the chassis rack structure directly next to the system power supply modules. While the 125744-02 executes vital baseline management roles including processing global system contact inputs, handling trip multiply controls, and running the internal OK relay, it functions independently of the critical machinery safety trip path, ensuring that any module-level service action has zero effect on the continuous, normal protective operations of the monitoring system.

Features

  • Standard full-height front rack architecture optimized for slot 1 integration 
  • Direct physical interface for proprietary system programming and diagnostics data collection 
  • Front-panel keylock module allowing explicit hardware switching between RUN and PROGRAM modes 
  • Dedicated "OK" relay output indicating overall 3500 protection rack health and internal diagnostics status 
  • Front-panel status LEDs providing physical validation for system communications, errors, and trip conditions 
  • Integrated front-panel rack reset pushbutton to clear active latched machinery alarms 

Applications

  • Main hardware integration point for standard configuration on 3500 machinery protection loops 
  • Condition monitoring data collection interfaces for industrial power turbines and compression lines 
  • Central localized control platform for large multi-slot machine casing and rotation protection frameworks 

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (A Baker Hughes Company)
Model 125744-02
Module Type Standard Rack Interface Module
Power Consumption 4.75 watts, typical 
Front Panel Interface RS232 serial communications at 38.4 k baud 
OK Relay Output Rating 5A @ 24 Vdc / 120 Vac (120 Watts / 600 VA Switched Power max) 
Operating Temperature -30 degC to +65 degC (-22 Fahrenheit to +150 Fahrenheit) 
Storage Temperature -40 degC to +85 degC (-40 Fahrenheit to +185 Fahrenheit) 
Relative Humidity 95%, non-condensing 
Rack Space Requirement (Main Board) 1 full-height front slot (Slot 1) 
Module Dimensions (H x W x D) 241.3 mm x 24.4 mm x 241.8 mm (9.5 in x 0.96 in x 9.52 in) 
Module Weight 0.91 kg (2.0 lb) 
Country of Origin United States

Connections/Interfaces

Interface Component Function
Front Panel Configuration Port Dedicated RS232 serial interface utilizing proprietary protocol for localized data collection and laptop rack setup 
Configuration Keylock Switch Rotational physical safety lock to switch between RUN mode (locks out changes) and PROGRAM mode (permits rack configuration) 
Chassis Status LEDs OK, TX/RX, TM (Trip Multiply), and CONFIG OK panel lamps indicating module operation and multi-card communication status 

Installation Guidelines

  • Slot Restrictions: Slide the interface card explicitly into the full-height Slot 1 location on the far left side of the machine protection rack.
  • Electrostatic Discharge Precautions: Utilize a proper grounding wrist strap connected to a solid electrical earth before inserting or setting up the circuit cards.
  • Keylock Integrity: Turn the front key switch to RUN position and extract the physical key to securely block unauthorized remote or local modification attempts.
  • Thermal Management: Ensure that cooling pathways are completely clear, maintaining the ambient temperature immediately surrounding the module chassis below 65 degC.

FAQ

What is the functional difference between RUN mode and PROGRAM mode on this module?

RUN mode permits typical system protective operation while completely locking out configuration changes. PROGRAM mode keeps the rack protective pathways running normally while opening the localized ports to allow engineers to change settings or updates.

Does a firmware update or a technical problem with this interface drop the machine trip loop?

No, the module performs configuration, diagnostic collection, and status tasks. It is placed outside the critical emergency protective monitoring loop and has no effect on individual monitor card shutdown capabilities.

How do you change or clear latched warning signs on the rack using this module faceplate?

Press the physical Rack Reset switch located on the front panel face to clear active latched machinery alerts or reset Timed OK Channel Defeat states.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/20 125744-02 Rack Interface Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
AC-powered DC Power

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.