Description

The Bently Nevada 350500-00-00-00-11-00 is a Dynamic Pressure Charge Amplifier (DPCA) designed as a fundamental signal conditioning component for specialized gas turbine monitoring applications. Its primary function is to monitor high-frequency pressure pulsations that manifest due to combustion instability inside industrial gas turbine engines.

The complete sensing system encompasses a charge-coupled piezoelectric pressure sensor, a specialized low-noise interconnect cable, the 350500 charge amplifier, and an external monitoring device. The high-temperature piezoelectric sensor converts detected dynamic pressure fluctuations into a raw electrostatic charge signal scaled in pico-coulombs per unit of pressure (pC/psi or pC/bar). The 350500-00-00-00-11-00 interfaces with this sensor to convert the high-impedance charge signal into a low-impedance voltage output. This processed voltage signal is fully compatible with rack-mounted monitoring devices, such as the Bently Nevada 3500/64 Dynamic Pressure Monitor. The standard electrical interface from the monitor to the charge amplifier supplies -24 Vdc power, instrument common, and signal return paths over the exact same structural wiring layout utilized by standard Bently Nevada proximity probe systems.

Features

  • High-accuracy charge-to-voltage conversion tailored for gas turbine combustion monitoring.
  • Low-impedance voltage output layout compatible with standard machinery protection systems.
  • Three-conductor SpringLoc terminal block design allowing secure field terminations.
  • Designed for standard 35 mm DIN rail installation configurations.
  • Standardized 3-pin MIL connector input interface for robust sensor tracking.
  • Electrical matching to -24 Vdc instrumentation infrastructure allowing standard proximity-style loop designs.

Applications

  • Gas turbine combustion instability monitoring
  • Combustion chamber pressure pulsation analysis
  • High-temperature piezoelectric sensor signal conditioning
  • Dynamic pressure wave measurements on heavy-duty rotary assets

Ordering Information

The configuration for model 350500-00-00-00-11-00 is derived directly from the official product breakdown options:

  • 350500: Dynamic Pressure Charge Amplifier Main Model Identifier.
  • 00 (A - Input Sensitivity Option): 16 pC/psi (232 pC/bar) with a nominal Pole-to-Pole capacitance range of 60 to 90 picofarads.
  • 00 (B - Low Pass Frequency Option): High.
  • 00 (C - Output Sensitivity Option): 100 mV/psi (1.45 V/bar) ±2% @ 150 Hz.
  • 11 (D - Mounting Option): DIN Mount, MIL Connector.
  • 00 (E - Approvals): No Approvals.

Technical Specifications

Category Parameter Specification
Manufacturer Brand Bently Nevada
Model / Suffix Part Number 350500-00-00-00-11-00
Power Requirements Voltage (Without Safety Barriers) -19.60 Vdc to -26 Vdc (at the module)
Voltage (With Safety Barriers) -17.75 Vdc to -26 Vdc (at the module)
Supply Current (No Load) 14.68 mA maximum, 11.69 mA typical
Input Parameters Input Sensitivity (Option 00) 16 pC/psi (232 pC/bar)
Expected Pole-Pole Capacitance 60 to 90 picofarads
Output Parameters Output Sensitivity (Option 00) 100 millivolt/psi (1.45 Volt/bar) ±2% @ 150 Hz
Dynamic Range ±50 psi pk
Common Mode Rejection Ratio -40 dB or better in the passband
Output Resistance 50 ohm typical
Physical Characteristics Weight 246 grams (8.7 oz)
Mounting Type 35 mm DIN rail mount
Environmental Limits Operating Temperature -20 Celsius to +70 Celsius (-4 Fahrenheit to +158 Fahrenheit)
Storage Temperature -40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit)
Humidity Bounds 0% to 95% relative humidity, non-condensing
Field Connections Power/Signal Connector Type Three-conductor SpringLoc terminal strip
Wire Size (Without Ferrules) 0.2 mm2 to 1.5 mm2 (16 to 24 AWG)
Wire Size (With Ferrules) 0.25 mm2 to 0.75 mm2 (18 to 23 AWG)
Recommended Cable Type Three-conductor shielded triad
Maximum Monitor Loop Distance 305 meters (1000 feet)
Sensor Interface Sensor Connector Type Three-pin MIL Connector MS31128-3P (mates to MS3116F8-3S or equivalent)

Connections/Interfaces

Terminal / Connector Function
SpringLoc Terminal 1 Power Input (-24 Vdc nominal power feed from rack monitor)
SpringLoc Terminal 2 Instrument Common (Signal ground and return reference)
SpringLoc Terminal 3 Low-Impedance Voltage Signal Output to monitoring system
MS31128-3P MIL Connector Three-pin dedicated input interfacing with low-noise piezoelectric sensor cable

Mechanical Dimensions

Category Parameter Specification
Manufacturer Brand Bently Nevada
Model Part Number 350500 DIN Mount Option
Datasheet Document Document Number 145828 Rev. W
Mechanical Dimensions Height 2.79 inches MAX (70.9 mm)
Width (Standard Base) 3.52 inches MAX (89.4 mm)
Width (Extended/Interface Base) 3.63 inches MAX (92.2 mm)
Total Depth 1.25 inches MAX (31.8 mm)
Mounting Hardware Profile Type Standard 35 mm DIN rail mount footprint

Installation Guidelines

  • Mounting Configuration: Ensure the unit is firmly seated on a standard 35 mm DIN rail tracking layout inside an appropriate structural junction box or control cabinet.
  • Sensor Cabling: Connect the high-temperature piezoelectric sensor via the specified low-noise, environmentally robust cable to prevent extraneous electrostatic charge accumulation.
  • Field Wiring Requirements: Use a high-quality three-conductor shielded triad for field connections between the charge amplifier and the monitoring rack to suppress external EMI/RFI noise.
  • Distance Constraints: Do not exceed the maximum allowable field cable run length of 305 meters (1000 feet) to the monitoring instrument to prevent voltage drops or loop attenuation.
  • Safety Barrier Implementation: Ensure any safety barriers required by the application layout are placed along the loops connecting the charge amplifier output back to the primary rack monitoring card.

FAQ

What is the core function of the 350500 charge amplifier?

It converts high-impedance electrostatic charge signals generated by a piezoelectric pressure sensor into a stable, low-impedance voltage output.

What specific industrial problem does this module help detect?

It monitors high-frequency dynamic pressure pulsations caused by combustion instability inside gas turbine environments.

What is the factory-configured input sensitivity of this specific part number?

This specific unit (Option 00) is set for an input sensitivity of 16 pC/psi (232 pC/bar).

What output sensitivity is delivered by this charge amplifier?

It outputs a low-impedance voltage signal calibrated to 100 millivolts/psi (1.45 Volts/bar).

What type of sensor connector does this exact configuration utilize?

It is built with a standard 3-pin MIL Connector (MS31128-3P), which mates directly with an MS3116F8-3S connector or its equivalent.

How does the unit receive operating power?

It draws power over a standard 3-wire system configuration from the rack monitor, operating between -19.60 Vdc and -26 Vdc under standard non-barrier loop conditions.

What is the maximum field wiring distance permitted to the monitoring rack?

The maximum allowable run for the three-conductor shielded triad cable is 305 meters or 1000 feet.

What type of terminal blocks are used for field wiring on the unit?

The card features a three-conductor SpringLoc terminal strip that accepts wire gauges up to 16 AWG without ferrules.

Does this specific part number carry hazardous area approvals?

No, suffix option 00 dictates that this specific model variation is shipped with no hazardous area approval certifications.

What rack monitoring module interfaces with this charge amplifier?

It is fully compatible with standard machinery monitoring systems, such as the Bently Nevada 3500/64 Dynamic Pressure Monitor card.

What is the nominal pole-to-pole capacitance range for this input layout?

The nominal pole-to-pole tracking capacitance value for the 16 pC/psi input selection is 60 to 90 picofarads.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Blue
Country of origin
United States

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...