Description

The GE Fanuc IC695PSD040F is a 40-Watt DC-to-DC power supply designed for installation in PACSystems RX3i Universal Backplanes (IC695 series). Operating from an input voltage source in the range of 18 VDC to 30 VDC , this module provides three essential internal outputs: +5.1 VDC , +24 VDC relay power to supply circuits on Output Relay modules , and +3.3 VDC utilized internally by RX3i modules with IC695 catalog numbers. The IC695PSD040F model specifically resolves an issue identified in previous revisions where the power supply occasionally failed to power up when installed in a 16-Slot Universal Backplane (IC695CHS016). It occupies exactly one backplane slot and features an internal diagnostic fault reporting system that communicates with the CPU to log system faults or power loss occurrences.

Features

  • Output Capabilities: Provides three highly regulated output channels including +5.1 VDC , +24 VDC relay power , and +3.3 VDC.
  • Integrated Hardware ON/OFF Switch: Equipped with a front-panel toggle switch protected by an access door to govern output delivery without interrupting the main incoming line power.
  • System Diagnostics and Status LEDs: Includes four diagnostic front-panel LEDs to indicate real-time status: Power, P/S Fault, Over Temperature, and Overload.
  • Overcurrent Protection Mechanism: Features an electronic limit on the 5.1 VDC output (7 Amps) and the 3.3 VDC output (10 Amps) with continuous automatic restart attempts during an active overload state.
  • Overvoltage Protection Option: Features a bottom-mounted screw terminal configuration with a jumper strap to frame ground for incoming overvoltage protection.

Applications

  • PACSystems RX3i backplane configuration deployments 
  • Industrial control systems utilizing Output Relay modules 
  • Pollution Degree 2 operating environments 

Ordering Information

Part Number Option/Description
IC695PSD040F Standard 40W 24 VDC Input Power Supply Module 
IC695PSD040CA Conformal Coated Version
IC695PSD040LT Low Temperature Version

Technical Specifications

Specification Description
Manufacturer GE Fanuc / Emerson 
Model IC695PSD040F 
Nominal Rated Voltage 24 VDC 
Input Voltage Range 18 to 30 VDC 
Input Power 60 Watts maximum at full load 
Inrush Current 4 Amps, 100 milliseconds maximum 
Output Power 40 Watts maximum total of all loads (5.1 VDC: 30 Watts max; 3.3 VDC: 30 Watts max) 
Output Voltage 5.1 VDC: 5.0 VDC to 5.25 VDC; 3.3 VDC: 3.2 VDC to 3.465 VDC 
Output Current 5.1 VDC: 0 to 6 Amps; 3.3 VDC: 0 to 9 Amps 
Isolation None (input to backplane) 
Ripple and Noise 50 mV (all outputs) 
Ride-Through Time 10 ms (duration outputs are maintained upon source input interruption) 
Terminal Current 6 Amps 
Wiring Requirements 14 AWG to 22 AWG copper conductors rated 75 Celsius minimum 
Operating Temperature 0 to 60 Celsius (Full output power available up to 40 Celsius) 
Storage Temperature -40 to +85 Celsius
Humidity 5% to 95% non-condensing

Connections/Interfaces

Connector Pin Function
+ Positive DC Power Input 
+ Positive Connection to additional daisy-chained units 
- Negative DC Power Input 
- Negative Connection to additional daisy-chained units 
Frame Ground Symbol System Frame Ground Connection (connect directly to mounting panel) 
Frame Ground Symbol Jumper Strap Connection for Overvoltage Protection 
MOV Disconnect Symbol Overvoltage Protection Device Connection 

Installation Guidelines

  • Backplane Limitation: Install only one IC695PSD040F power supply in a single PACSystems RX3i Universal Backplane. It cannot be utilized in multiple power supply systems to achieve load sharing or reduncancy.
  • Connection Polarity: Ensure connection polarity is identical at each RX3i power supply when using the same external DC power source across multiple units to prevent equipment damage or personal injury.
  • Common Grounding: Connect each backplane to a common system ground, keeping frame ground wiring paths as short as possible.
  • Wiring Terminal Torque: Strip individual wire ends between 9 mm and 11 mm. Insert fully into the terminal before tightening. Do not exceed the maximum terminal screw torque limit of 0.5 N-m (4.4 inch-lbs).
  • High-Potential Testing: Temporarily disable overvoltage protection by removing the jumper strap from the bottom terminal prior to running a Hi-pot test. Reinstall the jumper once testing is complete.

Compliance and Certifications

  • UL
  • CE
  • ATEX
  • CCC
  • KC
  • Marine (ABS)
  • Class I, Division 2, Groups A, B, C, D 
  • Class I, Zone 2 
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Fanuc IC695PSD040F PACSystems RX3i Power Supply Module

Can the power supply support redundant operations or load sharing?

No, the power supply does not support load sharing or redundancy and cannot be used in a parallel configuration with other RX3i power supply modules.

What is the consequence of momentary loss on the 24 VDC input power source?

A momentary drop in the 24 VDC input may cause the internal +24 VDC relay power to temporarily drop out, which can cause connected output relay module circuits to drop out, while the +5.1 VDC and +3.3 VDC outputs remain unaffected for up to 10 ms.

How is overcurrent handled within the device?

The device features electronic overcurrent limits set to 7 Amps on the 5.1 VDC output and 10 Amps on the 3.3 VDC output. Upon detecting an overload or short circuit, the device shuts down and continuously attempts to restart.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...